• 제목/요약/키워드: grids

검색결과 1,143건 처리시간 0.023초

Retrofitting of squat masonry walls by FRP grids bonded by cement-based mortar

  • Popa, Viorel;Pascu, Radu;Papurcu, Andrei;Albota, Emil
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.125-139
    • /
    • 2016
  • For seismic retrofitting of masonry walls, the use of fibre reinforced cement-based mortar for bonding the fibre grids can eliminate some of the shortcomings related to the use of resin as bonding material. The results of an experimental testing program on masonry walls retrofitted with fibre reinforced mortar and fibre grids are presented in this paper. Seven squat masonry walls were tested under unidirectional lateral displacement reversals and constant axial load. Steel anchors were used to increase the effectiveness of the bond between the fibre grids and the masonry walls. Application of fibre grids on both lateral faces of the walls effectively improved the hysteretic behaviour and specimens could be loaded until slip occurred in the horizontal joint between the masonry and the bottom concrete stub. Application of the fibre grids on a single face did not effectively improve the hysteretic behaviour. Retrofitting with fibre reinforced mortar only prevented the early damage but did not effectively increase deformation capacity. When the boundaries of the cross sections were not properly confined, midplane splitting of the masonry walls occurred. Steel anchors embedded in the walls in the corners area effectively prevented this type of failure.

주파수영역 음향 파동방정식에서 최소 격자수 결정을 위한 격자분산 분석 (A Dispersion Analysis for Minimum Grids in the Frequency Domain Acoustic Wave Equation)

  • 장성형;신창수;윤광진;서상용;신성렬
    • 지구물리와물리탐사
    • /
    • 제3권2호
    • /
    • pp.39-47
    • /
    • 2000
  • 복잡한 지층구조에 대한 파동방정식의 해를 유한 차분법을 이용하여 구하는것은 많은 컴퓨터 계산시간과 기억 용량이 필요하다. 컴퓨터 계산시간과 기억용량은 최소 파장당 격자수를 줄이므로써 감소 시킬 수 있지만 수치분산으로 인해 정확도가 떨어지게 마련이다. 본 연구에서는 정확도를 유지하면서 파장당 격자수를 줄이는 방법으로 이용되고 있는 가중평균법을 최대 169점 까지 확장하여 주파수 영역에서 음향파동방정식의 해를 유한차분법으로 구할 때 최소 격자수를 구하기 위한 격자분석을 실시하였다. 지금까지 수치오차가 정확도 $1\%$내에 존재하기 위해서는 일반적인 5점을 이용하는 경우 파장당 격자수가 13개 이상이 필요하고, 9점의 경우 9개, 25점에서는 3개, 49점에서는 2.7개 이상이 필요하였다. 본 연구에서 정확도를 유지하기 위한 최소격자수를 결정하기 위해 실시된 격자분석 결과 81점에서는 2.5개 121점에서는 2.3개 그리고 169점에서는 오차 한계를 벗어나 가중평균 계수를 구할 수 없었으며 격자수를 2개까지 줄일 수 없음을 알 수 있었다. 또한 격자분석을 통해 가중평균에 적용되는 격자수가 증가할수록 정확도는 증가하지만 차분식 자체가 증가하여 매우 복잡하게 된다.

  • PDF

A SYMMETRIC FINITE VOLUME ELEMENT SCHEME ON TETRAHEDRON GRIDS

  • Nie, Cunyun;Tan, Min
    • 대한수학회지
    • /
    • 제49권4호
    • /
    • pp.765-778
    • /
    • 2012
  • We construct a symmetric finite volume element (SFVE) scheme for a self-adjoint elliptic problem on tetrahedron grids and prove that our new scheme has optimal convergent order for the solution and has superconvergent order for the flux when grids are quasi-uniform and regular. The symmetry of our scheme is helpful to solve efficiently the corresponding discrete system. Numerical experiments are carried out to confirm the theoretical results.

바우 스러스터 터널 그리드 개선을 위한 연구 (A Development of New Device for Bow Thruster Tunnel Grids)

  • 김성표;박제준;전동수;김용수;이춘주
    • 대한조선학회논문집
    • /
    • 제43권3호
    • /
    • pp.304-312
    • /
    • 2006
  • For protection of the thruster against mechanical damage and reduction of tunnel resistance at ship forward speed, the tunnel grids are normally installed. Some of ship operators however, have a strong distrust of the protective function of the tunnel grids and so they do not want to install the protective grids for higher thruster efficiency. Since the grids should be installed at very close to the side shell as far as possible in due consideration of flow direction to minimize additional resistance induced by tunnel openings, it has been too hard and time consuming work to install the grids on the curved and chamfered tunnel entrances considering its relatively low resistance reduction effect. DSME (Daewoo Shipbuilding & Marine Engineering Co., Ltd) developed a substituting device named TG (Tunnel Guides) for bow thruster tunnel grids which is characterized by higher resistance reduction, higher thruster efficiency and easy to installation. This paper provides the principle idea of the TG with short history of the development using CFD calculations and model experiments in MOERI (former KRISO).

배선 함몰 전극의 배선 소결공정 최적화에 따른 전기적 특성 향상 (Improving Conductivity of Metal Grids by Controlling Sintering Process)

  • 안원민;정성훈;김도근
    • 한국표면공학회지
    • /
    • 제48권4호
    • /
    • pp.158-162
    • /
    • 2015
  • To substitute indium tin oxide (ITO), many substituents have been studied such as metal nanowires, carbon based materials, 2D materials, and conducting polymers. These materials are not good enough to apply to an electrode because theses exhibit relatively high resistance. So metal grids are required as an additionalelectrode to improve the conductivities of substituents. The metal grids were printed by electrohydrodynamic printing system using Ag nanoparticle based ink. The Ag grids showed high uniformity and the line width was about $10{\mu}m$. The Ag nanoparticles are surrounded by dispersants such as unimolecular and polymer to prevent aggregation between Ag nanoparticles. The dispersants lead to low conductivity of Ag grids. Thus, the sintering process of Ag nanoparticles is strongly recommended to remove dispersants and connect each nanoparticles. For sintering process, the interface and microstructure of the Ag grid were controlled in 1.0 torr Ar atmosphere at aound $400^{\circ}C$ of temperature. From the sintering process, the uniformity of the Ag grid was improved and the defects on the Ag grids were reduced. As a result, the resistivity of Ag grid was greatly reduced up to $5.03({\pm}0.10){\times}10^{-6}{\Omega}{\cdot}cm$. The metal grids embedded substrates containing low pressure Ar sintered Ag grids showed 90.4% of transmittance in visible range with $0.43{\Omega}/{\square}$ of sheet resistance.

FEM-FCT 기법을 이용한 코로나 방전 시뮬레이션에 대한 연구 (A Study on the Corona Discharge Simulation Using FEM-FCT Method)

  • 민웅기;김형석;이석현;한송엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.200-208
    • /
    • 1999
  • In this paper, the corona discharge is analyzed by Finite Element Method(FEM) combined with Flux-corrected Transport(FCT) algorithm. In the previous papers, Finite Difference Method(FDM) combined with FCT was used. Usually in the FDM, the regionof interest is discretized with structured grids. But to refine local regions with same resolution, much more grids are required for the structured grids than for unstructured grids than for unstructured grids. Therefore, we propose the FEM-FCT method to simulate the corona discharge. The proposed method has good flexibility in model shape and can reduce the computational cost by the local refinement where the physical quantities have steep gradients. Using the proposed method, we study the streamer growth of parallel plate electrodes which is initiated by the low and high perturbation density. We find that the varying the initial density of perturbation has very little effect on the streamer propagation. And the corona discharge of the rod-to-plane electrode is simulated. On the surface of the rod electrode, the high concentration of the electric field gives rise to many number of streamer seeds. The strong axial streamer propagate to the plane electrode. The weaker non-axial streamer repel each other and stop growing more. The results are very similar to those of the papers which used the FDM-FCT method on structured grids. Thus we can conclude that the proposed FEM-FCT method is more efficient than the conventional FDM-FCT method by virtue of the reduction in computational grids number.

  • PDF

다차원 공간 제한 기법의 3차원 비정렬 격자계로 확장 (EXTENSION OF MULTI-DIMENSIONAL LIMITING PROCESS ONTO THREE-DIMENSIONAL UNSTRUCTURED GRIDS)

  • 박진석;김종암
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.404-411
    • /
    • 2010
  • The present paper deals with the continuous work of extending multi-dimensional limiting process (MLP), which has been quite successfully proposed on two- and three-dimensional structured grids, onto the unstructured grids. The basic idea of the present limiting strategy is to control the distribution of both cell-centered and cell-vertex physical properties to mimic a multi-dimensional nature of flow physics, which can be formulated as so called the MLP condition. The MLP condition can guarantee a high-order spatial accuracy without yielding spurious oscillations. Recently, MLP slope limiter was proposed based on the MUSCL-type reconstruction in two-dimensional case and it can be readily extended to three-dimensional case. Through various numerical analyses and extensive computations, it is observed that the proposed limiters are quite effective in controlling numerical oscillations and very accurate in capturing both discontinuous and continuous multi-dimensional flow features on 3-D tetrahedral grids.

  • PDF

용접 띠철근으로 보강된 철근콘크리트 기둥의 강도와 연성(II) - 보편적인 띠철근 보강 기둥과의 비교를 중심으로 (Strength and Ductility of R/C Columns with Welded Reinforcement Grids(II) - Focused on Comparisons with Columns Confined by Conventional Reinforcement)

  • 최상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.561-568
    • /
    • 1997
  • Conventional confinement reinforcement for rectangular columns consist of closely spaced perimeter hoops, overlapping hoops, and crossties. One of the potential alternatives to conventional reinforcement is a welded reinforcement grid, prefabricated to required size and volumetric ratio of transverse reinforcement. An experimental investigation was carried out to investigate the strength and deformability of reinforced concrete columns confined with welded reinforcement grids. The comparisons of the envelopes of experimental force-displacement hysteric relationships for columns confined by welded grids with analytically generated force-displacement curves for columns confined with conventional ties. In general, inelastic deformability beyond the peak, as indicate by the slope of the cuvers, was similar to those indicated by columns with conventional ties. The superior performance of columns with welded grids may be attributed to the improved confinement characteristics of grids associated with increased rigidity of welded ties.

  • PDF

방향성을 갖는 비정렬 삼각형격자를 이용한 단조 유선 Upwind 유한요소해석 (The Monotone Streamline Upwind Finite Element Method Using Directionally Aligned Unstructured Grids)

  • 지선구;권장혁
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.49-54
    • /
    • 1997
  • Rice's monotone streamline upwind finite element method, which was proposed to treat convection-dominated flows, is applied to the linear triangular element. An alignment technique of unstructured grids with given velocity fields is used to prevent the interpolation error produced in evaluating the convection term in the upwind method. The alignment of grids is accomplished by optimizing a target function defined with the inner-product of a properly chosen side vector in the element with the velocity field. Two pure advection problems are considered to demonstrate the superiorities of the present approach in solving the convection-dominated flow on the unstructured grid. Solutions obtained with aligned grids are much closer to the exact solutions than those with initial regular grids. The capability of the present approach in predicting the appearance of the secondary vortex in the laminar confined jet impingement is shown by comparing streamlines to those produced by SIMPLE on a highly stretched grid toward the impingement plate.

  • PDF

Enhanced Electrochemical Reactivity at Electrolyte/electrode Interfaces of Solid Oxide Fuel Cells with Ag Grids

  • Choi, Mingi;Hwang, Sangyeon;Byun, Doyoung;Lee, Wonyoung
    • 한국세라믹학회지
    • /
    • 제52권5호
    • /
    • pp.356-360
    • /
    • 2015
  • The specific role of current collectors was investigated at the electrolyte/electrode interface of solid oxide fuel cells (SOFCs). Ag grids were fabricated as current collectors using electrohydrodynamic (EHD) jet printing for precise control of the grid geometry. The Ag grids reduced both the ohmic and polarization resistances as the pitch of the Ag grids decreased from $400{\mu}m$ to $100{\mu}m$. The effective electron distribution along the Ag grids improved the charge transport and transfer at the interface, extending the active reaction sites. Our results demonstrate the applicability of EHD jet printing to the fabrication of efficient current collectors for performance enhancement of SOFCs.