• 제목/요약/키워드: grid connection

검색결과 307건 처리시간 0.031초

MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계 (The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK)

  • 안해준;김현구;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

Power Flow Control of Modular Multilevel Converter based on Double-Star Bridge Cells Applying to Grid Connection

  • Hamasaki, Shin-Ichi;Okamura, Kazuki;Tsuji, Mineo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.246-253
    • /
    • 2013
  • The Modular Multilevel Converter (MMC) with full bridge cells is available for utility interactive inverter in high voltage line. When it is interconnected with power line, it is possible to control the active power flow in order to supply or charge the power in the line. This research applied the MMC to grid connection system of distributed generator and a power flow control for the MMC is investigated. Theory of power flow between the MMC and the power line is described and control method of power flow and capacitor voltages on arm cells for the MMC are proposed. And effectiveness of the proposed control method is presented by simulation.

태양광 발전소의 전기설비 설계 및 저압 계통연계 적용사례에 관한 연구 (A Study on electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station)

  • 임경미;김경화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2009
  • This paper resents a study on the electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station. The analysis for an installation cost is carried out and a new plan to solve the problem caused by a voltage drop in a low-voltage grid connection is devised. It is expected that the results can be usefully applied to spread the photovoltaic electric power station.

  • PDF

볼트 유격을 고려한 단층 그리드 노드 접합 시스템의 휨 강성에 대한 구조 해석적 평가 (Numerical Evaluation on Bending Stiffness of Nodal Connection Systems in the Single Layered Grid Considering Bolt Clearance)

  • 황경주
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.141-147
    • /
    • 2020
  • Single-layered grid space steel roof structure is an architectural system in which the structural ability of the nodal connection system greatly influences the stability of the entire structure. Many bolt connection systems have been suggested to enhance for better construct ability, but the structural behavior and maximum resistance of the connection system according to the size of bolt clearance play were difficult to identify. In particular, the identification of bending stiffness of the connection system is very important due to the characteristics of shell structures in which membrane stresses based on bending force effect significantly. To identify effective structural behavior and maximum bearing force, four representative nodal connection systems were selected and nonlinear numerical analysis were performed. The numerical analysis considering the size of the bolt clearance were performed to investigate structural behavior and maximum values of the bending force. In addition, the type of effective nodal connection system were evaluated. As a result, the connection system, which has two shear plane, represented high bending stiffness.

격자형 강합성 바닥판의 휨거동에 대한 실험적 연구 (An Experimental Study on the Bending Behaviour of Steel Grid Composite Deck)

  • 신현섭;이진형;박기태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.175-184
    • /
    • 2011
  • 구조용 형강을 사용하는 격자형 합성바닥판은 비교적 신속한 시공과 보수시 교통통제를 최소화할 수 있는 장점으로 인해 1930년대 이후 현재까지 다양한 단면상세가 연구개발 되고 있다. 강형의 상부 일부만 콘크리트와 합성된 형태를 취하는 격자형 합성바닥판은 강형이 완전히 매입되는 형태에 비해 자중이 작고 공장에서 프리캐스트 제작이 가능하여 원거리의 현장이나 산악지역과 같이 건설조건이 열악한 경우에도 적용이 가능한 구조이다. 본 연구에서는 형강이 노출된 격자형 강합성 바닥판을 각종 기반시설물의 수평지지구조에 적용하고자 형강과 콘크리트의 합성을 위한 전단연결부의 형식과 격자형 구조에서 형강을 서로 연결하는 가로막대의 간격, 상부 콘크리트 슬래브의 두께 등을 변수로 휨실험을 하였고, 휨성능 및 합성거동을 비교 평가하였다. 이를 통해 설계변수 변화에 따른 구조거동의 변화를 비교 검토할 수 있었고, 적절한 전단연결방식 및 단면제원에 대한 기본자료를 얻을 수 있었다.

축산폐기물 바이오 에너지 분산발전용 전처리시스템 개발 (Developement for Pretreatment System of Distributed Power Generation by using Livestock BIO-ENERGY)

  • 허광범;박정극;이정빈;임상규;김재훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.585-588
    • /
    • 2007
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection constrains. KEPCO (Korea Electric Power Corporation) is performing the project to develope the Distributed Micro Gas Turbine (MGT) technolgies by using Swine BIO-ENERGY. This paper describes the plans and strategies for the renewable energy of MGT on actual grid-connection under Korean situations. KEPCO also, has a research plan on bio-gas pretreatment system applicable to our domestic swine renewable resources and is performing concept design of pilot plant to test grid operation. In addition, this testing will be conducted in order to respond to a wide variety of needs for application and economic evaluation in the field of On-site generation.

  • PDF

마이크로 가스터빈 발전시스템 운전신뢰성평가 (Evaluation of Operation Reliability for Micro Gas Turbine(MGT) Power Generation System)

  • 김재훈;허광범
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.448-455
    • /
    • 2007
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. This paper describes the procedures and results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of MGT was developed, so that it will be able to analyze or propose new distributed generation system using MGT. The field test was conducted in order to respond to a wide variety of needs for noise reduction and utilization and its performance was evaluated in consideration of its operational problems. The MGT is successfully supplying electricity to Korean grids with satisfying various regulations. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

Smart Phone을 통한 Smart Grid 네트워크 접속에서 취약성 (Analysis of Smart Grid Network Vulnerability Using Smart Phone)

  • 이재현;박대우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.240-243
    • /
    • 2010
  • Smart Phone 보급이 확산되면서 인터넷 PC를 대체하는 모바일 통신으로 활용되고 있다. Smart Phone은 기존의 전력망과 IT가 융합된 Smart Grid에도서 업무용으로 사용되고 있다. 따라서 Smart Phone을 통한 Smart Grid 네트워크 접속에서 접속과 제어에 대한 보안 취약점과 Smart Grid 네트워크에 대한 취약점에 대한 연구가 필요하다. 본 논문에서는 Smart Phone을 사용하여 Smart Grid 네트워크를 통한 전력망 시스템에 접근할 때의 접속 취약점에 대한 연구를 한다. 또한 Smart Phone을 사용하여 Smart Grid 네트워크에 접속 한 후에 전력정보, 통제정보, 개인정보 등에 대한 접근 권한을 탈취 가능성에 취약성을 분석하여 발생하는 문제점과 대해 연구한다. 그리고 Smart Phone을 통한 Smart Grid 네트워크 보안 취약점에 대한 보안 강화를 위한 연구 방향을 제시하고자 한다.

  • PDF

Nonlinear modeling of flat-plate structures using grid beam elements

  • Tian, Ying;Chen, Jianwei;Said, Aly;Zhao, Jian
    • Computers and Concrete
    • /
    • 제10권5호
    • /
    • pp.489-505
    • /
    • 2012
  • This paper presents a simplified grid beam model for simulating the nonlinear response of reinforced concrete flat-plate structures. The beam elements are defined with nonlinear behavior for bending moment and torsion. The flexural stiffness and torsional strength of the beam elements are defined based on experimental data to implicitly account for slab two-way bending effects. A failure criterion that considers the interaction between the punching strength and slab flexural behavior is incorporated in the model. The effects of bond-slip of slab reinforcement on connection stiffness are examined. The proposed grid beam model is validated by simulating large-scale tests of slab-column connections subjected to concentric gravity loading and unbalanced moment. This study also determines the critical parameters for a hysteretic model used to simulate flat-plates subjected to cyclic lateral loading.

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.