• 제목/요약/키워드: greenhouse test

검색결과 434건 처리시간 0.031초

간척지에 플라스틱 온실 설치 시의 문제점 분석 및 개선방안 (An analysis of problems and countermeasures in the installation of plastic greenhouse on reclaimed lands)

  • 유인호;구양규;조명환;류희룡;문두경
    • 농업과학연구
    • /
    • 제41권4호
    • /
    • pp.473-480
    • /
    • 2014
  • Upon setting up a dedicated plastic greenhouse for tomato cultivation developed by the Rural Development Administration on the Gyehwa reclaimed land, this study was aimed at analyzing the problems can be occurred in the installation of plastic greenhouse on reclaimed lands as well as finding out solutions for improvement. A relatively cheaper wooden pile was used in the installation in order to supplement the soft ground conditions. Based on the results of ground investigation of the installation site, both the allowable bearing capacity and pulling resistance of the wooden pile with a diameter of 150 mm and a length of 10 m were computed and came out to be 30.645 kN. It was determined that the values were enough to withstand the maximum compressive force (17.206 kN) and the pullout force (20.435 kN) that are generally applied to the greenhouse footing. There are three problems aroused in the process of greenhouse installation, and the corresponding countermeasures are as follow. First, due to the slightly bent shape of the wooden pile, there were phenomenon such as deviation, torsion, and fracture when driving the pile. This could be prevented by the use of the backhoe (0.2) rotating tongs, which are holding the pile, to drive the pile while pushing to the direction of the driving and fixing it until 5 m below ground and applying a soft vibrating pressure until the first 2 m. Second, there exists a concrete independent footing between the column of the greenhouse and the wooden pile driven to the underground water level. Since it is difficult to accurately drive the pile on this independent footing, the problem of footing baseplate used to fix the column being off the independent footing was occurred. In order to handle with this matter, the diameter of the independent footing was changed from 200 mm to 300 mm. Last, after films were covered in the condition that the reinforcing frame and bracing are not installed, there was a phenomenon of columns being pushed away by the strong wind to the maximum of $11m{\cdot}s^{-1}$. It is encouraged to avoid constructions in winter, and the film covering jobs always to be done after the frame construction is completely over. The height of the independent footing was measured for 9 months after the completion of the greenhouse installation, and it was found to be within the margin of error meaning that there was no subsidence. The extent to the framework distortion and the value of inclinometers as well showed not much alteration. In other words, the wooden pile was designed to have a sufficient bearing capacity.

포그노즐을 이용한 온실냉방시스템 분석 (Fog Nozzle-Greenhouse Cooling System Analysis)

  • 김영중;유영선;윤진하;오권영;김승희
    • 생물환경조절학회지
    • /
    • 제6권1호
    • /
    • pp.48-54
    • /
    • 1997
  • 하절기 고온으로 인한 작물의 열악한 생육 환경개선을 위하여 미포그노즐을 이용하여 패트온실에서 증발 냉각 시험을 수행하였다. 본 연구에 사용된 미포그노즐의 분무특성을 말븐입자분석기로 분석한 결과 분무압 70kg/$\textrm{cm}^2$에서 분무입자의 크기는 평균 27$\mu\textrm{m}$로 나타났고, 이때의 분무량은 분당 100$m\ell$였다. 또한 평균 분무 입자의 크기가 27$\mu\textrm{m}$인 경우에 분무낙하량을 조사한 결과 낙하거리 150cm에서 총분무량의 88%가 공중에 부유하는 것으로 나타났다. 냉방시스템의 주요 구성 부분은 고압노즐, 양수펌프, 필터 및 미포그노즐 32개로 이루어졌고, 1분 분무-1분 환기로 이루어진 연속 분무 시험 결과 외기온 3$0^{\circ}C$의 조건에서 온실내 기온을 4$0^{\circ}C$에서 32$^{\circ}C$로 강하시킬 수 있었다 또한 분무시험시 측정한 온실내의 온습도 값을 psychrometric equation에 대입하여 온실내의 수분변화량을 분석할 수 있었으며, 이와 같은 분석을 통하여 온도강하정도와 온실내 공기의 절대습도비 변화량을 예측할 수 있는 실험식을 정립할 수 있었다. 이 실험식을 이용하여 우리 나라 표준형 온실 1-2W, 3-2G-3S에서 실내온도를 4$0^{\circ}C$에서 3$0^{\circ}C$로 강제 냉각시킬 때 필요한 분무수량을 분석한 결과 분무입자 27$\mu\textrm{m}$에서의 분무수량은 각각 80.7, 99.9$\ell$였으며, 포그시스템에 필요한 노즐의 수는 분당분무량 100$m\ell$의 경우 3분 분무기준으로 각각 270, 333개가 소요될 것으로 계산되었다. 앞으로 포그시스템을 활성화하기 위해서는 온실의 기상조건에 따른 증발율과 분무입자에 대한 심층적 연구가 요망된다.

  • PDF

아치형 단동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Single-Span Arched Greenhouse)

  • 이석건;이현우;권무남
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1995
  • One of the most destructive forces around greenhouses is wind. Wind loads can be obtained by multiplying velocity pressure by dimensionless wind force coefficient. Generally, wind force coefficients can be determined by wind tunnel experiments. The wind force coefficient distribution on a single - span arched greenhouse was estimated using experimental data and compared with reported values from various countries. The results obtained are as follows : 1. The coefficients obtained from this study agree with the values proposed by G. L. Nelson except about 0.5 of difference in the middle region of roof section. This discrepancy is mainly attributed to the dissimilarity of experimental conditions (or wind tunnel test such as Reynolds number, type of terrain, surface roughness of model, location of the lapping and measuring methods. 2. Considering that the wind force coefficients are varied along the height of a wall at wind direction perpendicular to wall, structural analysis using subdivided wind force coefficient distribution is more resonable for wall. 3. It is recommendable that wind force coefficient distribution on a roof should take more subdivision than the existing four equal divisions for more accurate structural design. 4. Structural design using wind forces close to real values is more advantageous in safety and expense.

  • PDF

논토양에서 돈분액비 시용에 따른 CH4 및 CO2 발생양상 (Emission Patterns of Carbon Dioxide & Methane by Liquid Pig Manure Treatments in Paddy Soil)

  • 오승가;윤동경;이은정;이병진;전승호;조영손
    • 한국유기농업학회지
    • /
    • 제23권4호
    • /
    • pp.923-938
    • /
    • 2015
  • This study was conducted to serve as the basis for establishing a standard cultivation, which enhances the alternative utilization of pig manure, a major cause of environmental pollution, by finding a means for reducing greenhouse gas emissions for eco-friendly cultivation. In a laboratory, $CH_4$ and $CO_2$ emission patterns were investigated corresponding to incremental pig manure treatments in paddy soil. The emissions peaked 12 to 27 days after manure application in the 100~400% applications. It was found that increasing applications of pig manure resulted an increase in $CH_4$ and $CO_2$ emissions. Additionally, application of more than 150% emitted a larger amount of these gasses than applying chemical fertilizer. However, the test application of 100% pig manure emitted a smaller amount of $CH_4$ and hence Global Warming Potential (GWP) than those emitted by chemical fertilizer. If appropriate amount of fertilization is applied in compliance with the standard application rate, the pig manure may be effective in reducing greenhouse gas emissions and the soil environment made more favorable than with the use of chemical fertilizer.

Damping-off of Edible Aster Caused by Rhizoctonia solani AG-4

  • Youn-Gi, Moon;Se-Won, Kim;Ki-Jin, Park;Wan-Gyu, Kim
    • 식물병연구
    • /
    • 제28권4호
    • /
    • pp.245-247
    • /
    • 2022
  • In August 2021, we surveyed diseases of wild vegetables grown in Taebaek, Gangwon Province, Korea. During the disease survey, we observed severe damping-off symptoms in young edible aster (Aster scaber) plants in a vinyl greenhouse investigated. The incidence of the disease in the plants ranged from 5% to 20%. Diseased plants of edible aster were collected from the vinyl greenhouse, and fungi were isolated from petiole lesions of the diseased plants. Rhizoctonia sp. was consistently isolated from the petiole lesions. We examined morphological characteristics and anastomosis groups of nine Rhizoctonia sp. isolates obtained from the petiole lesions. The examination results revealed that all the isolates corresponded to Rhizoctonia solani AG-4 based on the morphological characteristics and anastomosis test. Three isolates of R. solani AG-4 were tested for their pathogenicity on edible aster plants by artificial inoculation. Inoculation tests showed that the tested isolates caused damping-off symptoms on the inoculated plants. The induced symptoms were similar to those observed in the vinyl greenhouse investigated. Damping-off of edible aster caused by R. solani AG-4 is first reported in this study.

Greenhouse Test Results for Two Years of Sheet shaped Root Barrier Materials Apply to Green Roof System for Sustainable Building Construction

  • Jang, Dae-Hee;Kim, Hyeon-Soo;Choi, Soo-Kyung
    • 한국건축시공학회지
    • /
    • 제11권6호
    • /
    • pp.634-644
    • /
    • 2011
  • Recently, As a part of urban forestation, the introductions of green roofs into public projects has been actively driven. Supported by this policy, the sizes of domestic green roof related markets have been rapidly expanding and many types of root barrier materials developed in Korea or abroad are being commercially distributed. In this study, root barrier tests were conducted over two years with nine types of sheet type waterproof materials that are the most commonly used as root barrier layers in green roof systems. The test conditions prepared considered the climates, natural features and vegetation in Korea and the results and related root barrier performance were verified. From the results of this study, the necessity to improve the joint part of root barrier sheets and forming methods has been identified and a measure to improve domestic root barrier testing methods was proposed.

실시간교통정보 이용에 따른 가솔린차량의 온실가스 저감효과 평가 (Evaluating GHG Emissions Reduced by Real-time Traffic Information in Gasoline Vehicle)

  • 김준형;엄정섭
    • 한국대기환경학회지
    • /
    • 제27권4호
    • /
    • pp.443-453
    • /
    • 2011
  • Real-time Traffic Information Service could play a key role in reducing incomplete combustion time remarkably since it can provide traffic information in real-time basis. Emission characteristics of test engines were studied in terms of travel distance and speed. The present study focused on a north district in Daegu, 12 km. The driving for the emission test was done at 8AM, 3PM, 7PM which represents various traffic conditions. The reduced emissions of Greenhouse Gases (GHG) have been measured for a travel distance running at different loads (conventional shortest route and Real-time Traffic Information) and GHG ($CO_2$, $CH_4$, $N_2O$) are all inventoried and calculated in terms of existing emission factors. The emission of GHG has been shown to reduce linearly with travel distance: $CO_2$ (9.15%), $CH_4$ (18.43%), $N_2O$(18.62%).

산업의 온실가스 배출 행태 이해를 위한 지수분해분석 적합성 실증 연구 (Can Index Decomposition Analysis Give a Clue in Understanding Industry's Greenhouse Gas Footprint?)

  • 정환삼;스스무 토노
    • 자원ㆍ환경경제연구
    • /
    • 제24권1호
    • /
    • pp.55-84
    • /
    • 2015
  • 한국은 OECD 국가 가운데 교토협약에 따른 온실가스 감축의무를 갖지 않는 몇 안 되는 국가이다. 한국은 자발적으로 2015년부터 강력한 온실가스 감축을 단행하기로 하였다. 정부의 현정책들은 온실가스 감축에 따른 경제성장의 저하를 감안하지 않고 있어, 이 정책의 지속성이 제약된다. 이 점에서 산업의 부문별 특성을 감안한 감축전략이 더욱 친환경적 전략이 될 수 있다. 이 연구는 혼합단위를 사용한 에너지 산업연관분석에서부터 온실가스 배출에 유의미한 산업을 선정해 분해분석을 함으로써 유용성을 검증하였다. 유의미한 산업은 '유기화학기초제품군'과 '시멘트 및 콘크리트 산업'을 대상으로 삼았다. 변이는 에너지 소비, 생산, 공정개선 그리고 신시설의 도입 효과로 구분해 실증되었다. 이 연구에서 디비지아 분해분석 결과치들이 부분적으론 불안정적 시계열 패턴을 보였으나, 전체분석 과정으로 보면 일련의 분석과정은 대상산업의 에너지 사용과 온실가스 배출의 행태를 이해하기에 충분한 정보를 제공하였다.

온실가스 기기분석의 정도관리를 위한 고려사항 연구 - CH4과 CO2를 중심으로 - (Some Insights into the Basic QA/QC for the Greenhouse Gas Analysis: Methane and Carbon Dioxide)

  • 정재학;임호수;김기현;배위섭;전의찬
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.712-718
    • /
    • 2006
  • In order to investigate the analytical uncertainties associated with sampling and analysis of major greenhouse gaseous pollutants(carbon dioxide and methane), we attempted to quantify their adsorptive loss due to the contact with the container wall(such as Tedlar bag and vial). Using the GC/FID method, some basic experimental parameters(such as reproducibility and method detection limit) have been evaluated as part of the essential QA/QC The reproducibilities of carbon dioxide and methane were estimated as 2.02 and 0.2%, respectively. In addition, method detection limits were measured as 0.61 and 0.06 ng, respectively. A test of sample loss rate has also been made for Tedlar bag and vial by assessing the absolute amount of sample loss on the wall. By transferring the samples contained in Tedlar bag to various sizes of Tedlar bags, we measured differences in the absolute loss quantity due to such transfer. In addition, we also examined such loss mechanism as a function of elapsed time and light penetration rate for vial. As results, carbon dioxide and methane have shown about 2% of sample loss due to such contact. It is also noticed that the amount of loss with vial surface is lower than that of Tedlar bag. Therefore, field collection of greenhouse gases using various container types should be made more cautiously to minimize the possibility of sample loss and bias related to such loss.

히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성 (Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF