• Title/Summary/Keyword: gravimetric method

Search Result 209, Processing Time 0.023 seconds

Gravimetric and magnetic studies in an Yangsan fault area near Angang (안강부근 양산단층 지역에서의 중력 및 지자기 연구)

  • Kim, Gi Yeong;Lee, Gwang Ja
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.31-40
    • /
    • 1998
  • Gravimetric and magnetic surveys were conducted in order to reveal near-surface structures such as basements, faults, and fracture zones in an area near Angang, where the Yangsan fault is believed to pass through. Along two lines approximately perpendicular to the strike of the major fault, gravity and magnetic data were measured at 67 stations with a 15 m interval and at 296 stations with a 3 m interval, respectively. Average depth to the magnetic basement is estimated using the spectral analysis method to be 8.5 and 10.0 m along lines located to the east and the west of the Hyeongsan river, respectively. Average value of reduced gravity on the east line is higher than that on the west by the amount of 1.71 mGal, which indicates that the basement rocks are more severely fractured in the western part. Forward gravity modeling along the east line indicates that a fracture zone extends westward from a fault located 210 m west of the eastern end. Density and depth to the bottom of the fracture zone are estimated to be 2.44 g/cm3 and 70 m, respectively. The gravity model study also indicates presence of a small graben, 190 m wide and 3.5 m deep on an average, on the basement surface. The earth surface above the graben is approximately 44 cm lower than the nearby surface. This indicates that the graben might have been formed by recent fault movements.

  • PDF

Preparation of a Bi$_{4}$Ti$_{3}$O$_{12}$ Thin Film and Its Electrical Properties (Bi$_{4}$Ti$_{3}$O$_{12}$ 박막의 제작과 그 특성에 관한 연구)

  • Gang, Seong-Jun;Jang, Dong-Hun;Min, Gyeong-Jin;Kim, Seong-Jin;Jeong, Yang-Hui;Yun, Yeong-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.4
    • /
    • pp.7-14
    • /
    • 2000
  • A Bi$_{4}$Ti$_{3}$O$_{12}$ (BIT) thin film is prepared by sol-gel method using acetate precursors and evaluated whether it could be applied to NVFRAM (Non-Volatile Ferroelectric RAM). The drying and the annealing temperature are 40$0^{\circ}C$ and $650^{\circ}C$, respectively and they are determined from the DT-TG (Differential Thermal-Thermal Gravimetric) analysis. The BIT thin film deposited on Pt/Ta/SiO$_{2}$/Si substrate shows orthorhombic perovskite phase. The grain size and the surface roughness are about 100 nm and 70.2$\AA$, respectively. The dielectric constant and the loss tangent at 10 KHz are 176 and 0.038, respectively, and the leakage current density at 100 ㎸/cm is 4.71 $mutextrm{A}$/$\textrm{cm}^2$. In the results of hysteresis loops measured at $\pm$250 ㎸/cm, the remanent polarization (Pt) and the coercive field (Ec) are 5.92 $\mu$C/$\textrm{cm}^2$ and 86.3 ㎸/cm, respectively. After applying 10$^{9}$ square pulses of $\pm$5V, the remanent polarization of the BIT thin film decreases as much as about 33% from 5.92 $\mu$C/$\textrm{cm}^2$ of initial state to 3.95 $\mu$C/$\textrm{cm}^2$.

  • PDF

Purity Assessment of Organic Reference Materials with a Mass Balance Method: A Case Study of Endosulfan-II

  • Kim, Seung-Hyun;Lee, Joonhee;Ahn, Seonghee;Song, Young-Sin;Kim, Dong-Kyum;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.531-538
    • /
    • 2013
  • A mass balance method established in this laboratory was applied to determine the purity of an endosulfan-II pure substance. Gas chromatography-flame ionization detector (GC-FID) was used to measure organic impurities. Total of 10 structurally related organic impurities were detected by GC-FID in the material. Water content was determined to be 0.187% by Karl-Fischer (K-F) coulometry with an oven-drying method. Non-volatile residual impurities was not detected by Thermal gravimetric analysis (TGA) within the detection limit of 0.04% (0.7 ${\mu}g$ in absolute amount). Residual solvents within the substance were determined to be 0.007% in the Endosulfan-II pure substance by running GC-FID after dissolving it with two solvents. The purity of the endosulfan-II was finally assigned to be ($99.17{\pm}0.14$)%. Details of the mass balance method including interpretation and evaluating uncertainties of results from each individual methods and the finally assayed purity were also described.

Investigation of Low-Temperature Processed Amorphous ZnO TFTs Using a Sol-Gel Method

  • Chae, Seong Won;Yun, Ho Jin;Yang, Seung Dong;Jeong, Jun Kyo;Park, Jung Hyun;Kim, Yu Jeong;Kim, Hyo Jin;Lee, Ga-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.155-158
    • /
    • 2017
  • In this paper, ZnO Thin Film Transistors (TFTs) were fabricated by a sol-gel method using a low-temperature process, and their physical and electrical characteristics were analyzed. To lower the process temperature to $200^{\circ}C$, we used a zinc nitrate hydrate ($Zn(NO_3)_2{\cdot}xH_2O$) precursor. Thermo Gravimetric Analyzer (TGA) analysis showed that the zinc nitrate hydrate precursor solution had 1.5% residual organics, much less than the 6.5% of zinc acetate dihydrate at $200^{\circ}C$. In the sol-gel method, organic materials in the precursor disrupt formation of a high-quality film, and high-temperature annealing is needed to remove the organic residuals, which implies that, by using zinc nitrate hydrate, ZnO devices can be fabricated at a much lower temperature. Using an X-Ray Diffractometer (XRD) and an X-ray Photoelectron Spectrometer (XPS), $200^{\circ}C$ annealed ZnO film with zinc nitrate hydrate (ZnO (N)) was found to have an amorphous phase and much more oxygen vacancy ($V_o$) than Zn-O bonds. Despite no crystallinity, the ZnO (N) had conductance comparable to that of ZnO with zinc acetate dihydrate (ZnO (A)) annealed at $500^{\circ}C$ as in TFTs. These results show that sol-gel could be made a potent process for low-cost and flexible device applications by optimizing the precursors.

Nano Particle Emission Charataristics of Biodiesel (바이오디젤의 미세입자 배출특성)

  • Song, Hoyoung;Lee, Minho;Kim, Jaigueon;Jung, Choongsub
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • Biodiesels are well-known as alternative fuels. also we know that biodiesels increase NOx and reduce PM(Particulate Matter) by previous many studies. But PM in most these studies was considered about the mass. In this study, We have performed experimental test for PM and exhaust emission by mixed ratio of biodiesel in heavy duty diesel engine. PM was investigated by The nano particle number and the mass. The mass of PM was evaluated by using the standard gravimetric method, The number of PM was evaluated by using the EEPS(Engine Exhaust Particle Sizer), on the ESC(European Steady Cycle) mode. Sampled gas through dilutor was directly extracted from tail pipe and EEPS measured diluted exhaust gas. Biodiesel is made up of used cooking oil. Diesel as base fuel was sold on market and contains 2% biodiesel. The mass of PM was reduced 10% and the nano particle number was increased 5%. The particle number less than 40nm was increased, but the particle number more than 40nm is decreased.

  • PDF

Characteristics of PM10 Measured by Different Light-Scattering Instruments in Public Transport Vehicles (광산란 측정장치에 따른 대중교통차량 미세먼지 측정 특성)

  • Kwon, Soon-Bark;Jeong, Wootae;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • In this study, indoor $PM_{10}$ concentration was measured by different type of real-time instruments in public transport vehicles. Light-scattering method is widely used in measuring the size of particulate matters and there is two types of light-scattering methods; one is the nephelometer type which measures the light-scattering degree by aerosol cloud, the other is the spectrometer type which measures light-scattering degree by individual particle. We observed the variation of $PM_{10}$ in KTX, subway and express bus carriages by 1-minute resolution and found that there is similar tendency in pattern among 4 light-scattering devices but difference in absolute concentrations. By comparing gravimetric result in a subway cabin, the spectrometer type device, C, was chosen as a reference device. The conversion factors of nephelometer device A-1, A-2, and B were 1.666, 1.463 and 2.125 respectively.

Nanostructured Hydroxyapatite for Biomedical Applications: From Powder to Bioceramic

  • Eslami, Hossein;Tahriri, Mohammadreza;Moztarzadeh, Fathollah;Bader, Rizwan;Tayebi, Lobat
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.6
    • /
    • pp.597-607
    • /
    • 2018
  • In this study, a wet chemical method was used to synthesize nanostructured hydroxyapatite for biomedical applications. Diammonium hydrogen phosphate and calcium nitrate 4-hydrate were used as starting materials with a sodium hydroxide solution as an agent for pH adjustment. Scanning electron microscopy, transmission electron microscopy, Fourier-transform infrared spectroscopy, differential thermal analysis, thermal gravimetric analysis, atomic absorption spectroscopy, and ethylenediaminetetraacetic acid (EDTA) titration analysis were used to characterize the synthesized powders. Having been uniaxially pressed, the powders formed a disk-like shape. The sinterability and electrical properties of the samples were examined, and the three-point bending test allowed for the measurement of their mechanical properties. Sedimentation analysis was used to analyze the slurry ability of hydroxyapatite. As in-vitro biological properties of the samples, biocompatibility and cytotoxicity were assessed using osteoblast-like cells and the L929 cell line, respectively. Solubility was assessed by employing a simulated body fluid.

Analysis of Dietary Fiber Content of Some Vegetables, Mushrooms, Fruits and Seaweeds (채소류, 버섯류, 과일류 및 해조류 식품의 식이섬유 함량)

  • 황선희
    • Journal of Nutrition and Health
    • /
    • v.29 no.1
    • /
    • pp.89-96
    • /
    • 1996
  • This study was conducted to analyze dietary fiber content of 113 common Korean foods. Content of total dietary fiber(TDF) in vegetables, mushrooms, fruite, and seaweeds was determined by enzymatic-gravimetric method developed by Prosky et al. and adopted by AOAC. The average TDF content of the foods analyzed was 3.62$\pm$2.09% for green vegetables, 5.90$\pm$7.61% for light vegetables, 14.27$\pm$18.11% for mushrooms, 3.02$\pm$4.48% for fruits, and 11.39$\pm$12.68% for seaweeds. The foods containing the highest TDF values in the food groups were boiled radish leaves(10.84%) in green vegetables, dried braken(38.36%) in light vegetables, dried juda's ear(18.18%) in mushrooms except dried manna lichen(52.87%), dried persimon(17.73%) in fruits and dried sea mustard(37.77%) in seaweeds. Dried Seaweeds such as sea mustard (37.77%), sea tangle(29.30%), and laver(31.36%) were good sources of dietary fiber. When we consider the health and therapeutic benefits of dietary fiber, it is recommended to continue to consume traditional Korean diet which are mainly composed of vegetables rather than animal foods and to increase consumption of dried mushrooms and seaweeds which contain high content of TDF.

  • PDF

Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique (Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

Investigation on nanoadhesive bonding of plasma modified titanium for aerospace application

  • Ahmed, Sabbir;Chakrabarty, Debabrata;Mukherjee, Subroto;Joseph, Alphonsa;Jhala, Ghanshyam;Bhowmik, Shantanu
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • Physico-chemical changes of the plasma modified titanium alloy [Ti-6Al-4V] surface were studied with respect to their crystallographic changes by X-Ray Diffraction (XRD) and Scanning Electron Microscope (SEM).The plasma-treatment of surface was carried out to enhance adhesion of high performance nano reinforced epoxy adhesive, a phenomenon that was manifested in subsequent experimental results. The enhancement of adhesion as a consequence of improved spreading and wetting on metal surface was studied by contact angle (sessile drop method) and surface energy determination, which shows a distinct increase in polar component of surface energy. The synergism in bond strength was established by analyzing the lap-shear strength of titanium laminate. The extent of enhancement in thermal stability of the dispersed nanosilica particles reinforced epoxy adhesive was studied by Thermo Gravimetric Analysis (TGA), which shows an increase in onset of degradation and high amount of residuals at the high temperature range under study. The fractured surfaces of the joint were examined by Scanning electron microscope (SEM).