• Title/Summary/Keyword: graphite electrode

Search Result 257, Processing Time 0.026 seconds

Effect of Electrochemical Redox Reaction on Biochemical Ammonium Oxidation and Chemical Nitrite Oxidation

  • Jeon, Bo-Young;Seo, Ha-Na;Kang, Seung-Won;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.3
    • /
    • pp.485-493
    • /
    • 2010
  • A modified graphite felt electrode with neutral red (NR-electrode) was shown to catalyze the chemical oxidation of nitrite to nitrate under aerobic conditions. The electrochemically oxidized NR-electrode (EO-NR-electrode) and reduced NR-electrode (ER-NR-electrode) catalyzed the oxidation of $1,094{\pm}39$ mg/l and $382{\pm}45$ mg/l of nitrite, respectively, for 24 h. The electrically uncharged NR-electrode (EU-NR-electrode) catalyzed the oxidation of $345{\pm}47$ mg/l of nitrite for 24 h. The aerobic bacterial community immobilized in the EO-NR-electrode did not oxidize ammonium to nitrite; however, the aerobic bacterial community immobilized in the ER-NR-electrode bioelectrochemically oxidized $1,412{\pm}39$ mg/l of ammonium for 48 h. Meanwhile, the aerobic bacterial community immobilized on the EU-NR-electrode biochemically oxidized $449{\pm}22$ mg/l of ammonium for 48 h. In the continuous culture system, the aerobic bacterial community immobilized on the ER-NR-electrode bioelectrochemically oxidized a minimal $1,337{\pm}38$ mg/l to a maximal $1,480{\pm}38$ mg/l of ammonium to nitrate, and the community immobilized on the EU-NR-electrode biochemically oxidized a minimal $327{\pm}23$ mg/l to a maximal $412{\pm}26$ mg/l of ammonium to nitrate every two days. The bacterial communities cultivated in the ER-NR-electrode and EU-NR-electrode in the continuous culture system were analyzed by TGGE on the $20^{th}$ and $50^{th}$ days of incubation. Some ammonium-oxidizing bacteria were enriched on the ER-NR-electrode, but not on the EU-NR-electrode.

Rate-capability response of graphite anode materials in advanced energy storage systems: a structural comparison

  • Farooq, Umer;Doh, Chil-Hoon;Pervez, Syed Atif;Kim, Doo-Hun;Lee, Sang-Hoon;Saleem, Mohsin;Sim, Seong-Ju;Choi, Jeong-Hee
    • Carbon letters
    • /
    • v.17 no.1
    • /
    • pp.39-44
    • /
    • 2016
  • The work presented in this report was a detailed comparative study of the electrochemical response exhibited by graphite anodes in Li-ion batteries having different physical features. A comprehensive morphological and physical characterization was carried out for these graphite samples via X-ray diffraction and scanning electron microscopy. Later, the electrochemical performance was analyzed using galvanostatic charge/discharge testing and the galvanostatic intermittent titration technique for these graphite samples as negative electrode materials in battery operation. The results demonstrated that a material having a higher crystalline order exhibits enhanced electrochemical properties when evaluated in terms of rate-capability performance. All these materials were investigated at high C-rates ranging from 0.1C up to 10C. Such improved response was attributed to the crystalline morphology providing short layers, which facilitate rapid Li+ ions diffusivity and electron transport during the course of battery operation. The values obtained for the electrical conductivity of these graphite anodes support this possible explanation.

An ionic liquid incorporated gel polymer electrolyte for double layer capacitors

  • Perera, Kumudu S.;Prasadini, K.W.;Vidanapathirana, Kamal P.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 2020
  • Energy storage devices have received a keen interest throughout the world due to high power consumption. A large number of research activities are being conducted on electrochemical double layer capacitors (EDLCs) because of their high power density and higher energy density. In the present study, an EDLC was fabricated using natural graphite based electrodes and ionic liquid (IL) based gel polymer electrolyte (GPE). The IL based GPE was prepared using the IL, 1-ethyl-3-methylimidazolium trifluoromethanesulfonate (1E3MITF) with the polymer poly(vinyl chloride) (PVC) and the salt magnesium trifluoromethanesulfonate (Mg(CF3SO3)2 - MgTF). GPE was characterized by electrochemical impedance spectroscopy (EIS), DC polarization test, linear sweep voltammetry (LSV) test and cyclic voltammetry (CV) test. The maximum room temperature conductivity of the sample was 1.64 × 10-4 Scm-1. The electrolyte was purely an ionic conductor and the anionic contribution was prominent. Fabricated EDLC was characterized by EIS, CV and galvanostatic charge discharge (GCD) tests. CV test of the EDLC exhibits a single electrode specific capacitance of 1.44 Fg-1 initially and GCD test gives 0.83 Fg-1 as initial single electrode specific discharge capacitance. Moreover, a good stability was observed for prolonged cycling and the device can be used for applications with further modifications.

Humidification Optimization in Silicon-based Miniaturized Fuel Cell (실리콘으로 제작된 소형 연료 전지에서 가습 조건의 최적화)

  • Kwon, Oh-Joong;Won, Ho-Youn;Kim, Jae-Jeong
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.104-109
    • /
    • 2007
  • Single fuel cell was fabricated with a MEA (membrane electrode assembly) that had a $4cm^2$ active area and with silicon bipolar plates those were introduced to miniaturize the fuel cell by replacing heavy weight graphite plates. Optimum humidification condition for the single cell was selected based on performance results obtained varying humidifier temperature at a fixed feed rate of hydrogen and oxygen. Furthermore, to study the effect of humidification condition on the performance of a fuel cell stack, the fuel cell stack consisting of two MEAs and silicon bipolar plates was studied, then problems and characteristics of silicon-based fuel cell stack were examined.

Toxic Effect of Cadmium Assay in Contaminated Soil Earthworm Cell Using Modified Sensor

  • Ly, Suw Young;Kyung, Lee;Kim, Chae Hwa;Seo, Roma;Lee, Soo Youn;Kim, Lina;Chae, Su min;Choi, Sung Wook;Kim, Ji Yoon
    • Toxicological Research
    • /
    • v.31 no.2
    • /
    • pp.213-217
    • /
    • 2015
  • A voltammetric toxic metal of cadmium detection was studied using a fluorine doped graphite pencil electrode (FPE) in a seawater electrolyte. In this study, square wave (SW) stripping and chronoamerometry were used for determination of Cd(II) in seawater. Affordable pencils and an auxiliary electrode were used as reference. All experiments in this study could be performed at reasonable cost by using graphite pencil. The application was performed on the tissue of contaminated soil earthworm. The results show that the method can be applicable for vegetables and in vivo fluid or medicinal diagnosis.

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

Analysis of Electrochemical Properties of Sulfide All-Solid-State Lithium Ion Battery Anode Material Using Amorphous Carbon-Removed Graphite (비정질 탄소가 제거된 흑연을 이용한 황화물계 전고체 리튬이온전지 음극소재 전기화학적 특성 분석)

  • Choi, Jae Hong;Oh, Pilgun
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.58-63
    • /
    • 2022
  • Graphite has been used as an anode material for lithium-ion batteries for the past 30 years due to its low de-/lithiation voltage, high theoretical capacity of 372 mAh/g, low price, and long life properties. Recently, all-solid-state lithium-ion batteries (ASSLB), which are composed of inorganic solid materials with high stability, have received great attention as electric vehicles and next-generation energy storage devices, but research works on graphite that works well for ASSLB systems are insufficient. Therefore, we induced the performance improvement of ASSLB anode electrode graphite material by removing the amorphous carbon present in the carbon material surface, acting as a resistive layer from the graphite. As a result of X-ray diffraction (XRD) analysis using heat treated graphite in air at 400, 500, and 600 ℃, the full width at half maximum (FWHM) at (002) peak was reduced compared to that of bare graphite, indicating that the crystallinity of graphite was improved after heat treatment. In addition, the discharge capacity, initial coulombic efficiency (ICE) and cycle stability increased as the crystallinity of graphite increased after heat treatment. In the case of graphite annealed in air at 500 ℃, the high capacity retention rate of 331.1 mAh/g and ICE of 86.2% and capacity retention of 92.7% after 10-cycle measurement were shown.

Effect of Electrolyte Additive on the Electrochemical Characteristics of Lithium Vanadium Oxide Anode (전해질 첨가제가 리튬 바나듐 옥사이드 전극의 성능에 미치는 영향)

  • Lee, Je-Nam
    • Journal of the Korean Electrochemical Society
    • /
    • v.21 no.3
    • /
    • pp.55-60
    • /
    • 2018
  • The demand for LIBs with higher energy densities has increased continuously because the emergence of wider and more challenging applications including HEV and EV has became imperative. However, in the case of anode material, graphite is insufficient to meet this need. To meet such demand, several type of negative electrode materials like silicon, tin, SiO, and transition metal oxide have been investigated for the advanced lithium secondary batteries. Recently, lithium vanadium oxide, which has a layered structure, is assumed as one of the promising anode material as alternative of graphite. This material shows a high volumetric capacity, which is 1.5 times higher than that of graphite. However, relative low electrical conductivity and particle fracture, which results in the electrolyte decomposition and loss of electric contact between electrode, induce rapid capacity decay. In this report, we investigated the effect of electrolyte additive on the electrochemical characteristics of lithium vanadium oxide.

Quantitative Analysis of Skin Lotion Containing Rutin by Voltammetric Method Using Graphite Electrode (흑연전극을 사용한 전압전류법을 이용하여 스킨로션 중 루틴성분의 정량분석)

  • Kang, Myung-Kyu;Won, Bo-Ryoung;Lee, Dong-Kuk;Ly, Suw-Young;Park, Soo-Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.4
    • /
    • pp.325-331
    • /
    • 2009
  • We studied square-wave stripping voltammetry (SWV) to analyze quantitatively rutin contained in transparent skin-lotion using graphite electrode. The optimum analytical conditions for quantitative analysis of rutin were determined and the linear range was obtained of $1\;{\sim}\;8\;{\mu}g/mL$. The relative standard deviation of fifteen times repetition measurement for $0.1\;{\mu}g/mL$ of rutin was 0.080 and the detection limit was $0.01\;{\mu}g/mL$, respectively. We considered that this study could be used for quantitative analysis of active components contained in cosmetics.