• Title/Summary/Keyword: gradient ideal

Search Result 42, Processing Time 0.024 seconds

Analysis of Characteristics of Spent Fuels on Long-Term Dry Storage Condition

  • Yoon, Suji;Park, Kwangheon;Yun, Hyungju
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.2
    • /
    • pp.205-214
    • /
    • 2021
  • Currently, the interim storage pools of spent fuels in South Korea are expected to become saturated from 2024. It is required to prepare an operation plan of a domestic dry storage facility during a long-term period, with the researches on safety evaluation methods. This study modified the FRAPCON code to predict the spent fuel integrity evaluation such as the axial cladding temperature, the hoop stress and hydrogen distribution in dry storage. The cladding temperature in dry storage was calculated using the COBRA-SFS code with the burnup information which was calculated using the FRAPCON code. The hoop stress was calculated using the ideal gas equation with spent fuel information such as rod internal pressure. Numerical analysis method was used to calculate the degree of hydrogen diffusion according to the hydrogen concentration and temperature distribution during a dry storage period. Before 50 years of dry storage, the cladding temperature and hoop stress decreased rapidly. However, after 50 years, they decreased gradually and the cladding temperature was below 400 K. The initial temperature distribution and hydrogen concentration showed a parabolic line, but hydrogen was transferred by the hydrogen concentration and temperature gradient over time.

Hybrid CMA-ES/SPGD Algorithm for Phase Control of a Coherent Beam Combining System and its Performance Analysis by Numerical Simulations (CMA-ES/SPGD 이중 알고리즘을 통한 결맞음 빔 결합 시스템 위상제어 및 동작성능에 대한 전산모사 분석)

  • Minsu, Yeo;Hansol, Kim;Yoonchan, Jeong
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • In this study, we propose a hybrid phase-control algorithm for multi-channel coherent beam combining (CBC) system by combining the covariant matrix adaption evolution strategy (CMA-ES) and stochastic parallel gradient descent (SPGD) algorithms and analyze its operational performance. The proposed hybrid CMA-ES/SPGD algorithm is a sequential process which initially runs the CMA-ES algorithm until the combined final output intensity reaches a preset interim value, and then switches to running the SPGD algorithm to the end of the whole process. For ideal 7-channel and 19-channel all-fiber-based CBC systems, we have found that the mean convergence time can be reduced by about 10% in comparison with the case when the SPGD algorithm is implemented alone. Furthermore, we analyzed a more realistic situation in which some additional phase noise was introduced in the same CBC system. As a result, it is shown that the proposed algorithm reduces the mean convergence time by about 17% for a 7-channel CBC system and 16-27% for a 19-channel system compared to the existing SPGD alone algorithm. We expect that for implementing a CBC system in a real outdoor environment where phase noise cannot be ignored, the hybrid CMA-ES/SPGD algorithm proposed in this study will be exploited very usefully.

The Study of Body Type According to Drop Value of Women in Their 20's and Gradient of Brassiere Cup Size (20대 성인 여성의 드롭치에 따른 체형 분류 및 브래지어 컵 사이즈 변화 연구)

  • Jeong, Jin-Ah;Choi, Hei-Sun;Choi, Jeong-Wook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.6
    • /
    • pp.887-895
    • /
    • 2014
  • The study provides baseline data on developing ready-to-wear clothes for adult females in their twenties who have finished shaping their bodies and have realized an ideal shape. We analyzed the data from females aged from 20 to 29 in "The $5^{th}$ Size Korea Survey" and "The $6^{th}$ Size Korea Survey", and sorted body shapes into several types according to drop values before analyzing and comparing the characteristics among groups. We also referred to the change by year in the size of upper inner wear. To classify body shapes, three drop values were assigned for bust girth - waist girth, hip girth - waist girth, hip girth - bust girth; through cluster analysis all data were classified into three body types. Type 1 is more like normal body shapes with small drop values at the bust girth - waist girth and well-build lower body. Type 2 is X-shaped body shaped like a fiddle with big drop values at all parts. Type 3 is Y-shaped body with a big drop value at the bust girth - waist girth and well-build upper body. Type 2, X-shaped body, has the majority of distribution in every year, which proved to be the most idealistic body shape. There was a change in the brassiere cup size. Korean ladies in their twenties have larger breasts. The body shapes of Korean females in their twenties are increasingly like those of westerners. Bust girth is a very critical element to set measurements and design patterns for upper wear; consequently, a change in the size of breasts should be considered.

Analysis of Organic Components and Osteoinductivity in Autogenous Tooth Bone Graft Material

  • Kim, Young-Kyun;Lee, Junho;Kim, Kyung-Wook;Um, In-Woong;Murata, Masaru;Ito, Katsutoshi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.353-359
    • /
    • 2013
  • Purpose: Extensive research is actively ongoing for development of an ideal bone substitute that meets the gold standard. Tooth was selected as a donor site for evaluation of potentials in bone substitutes based on its similar chemical compositions to alveolar bone. Previous studies have evaluated inorganic components of autogenous tooth bone graft material (AutoBT) and osteoconductivity. In continuation from the previous studies, the current study was conducted for analysis of organic components and evaluation of osteoinductivity of AutoBT. Methods: Forty-six extracted teeth were collected from actual patients (Korea Tooth Bank, R&D Institute). Extracted teeth were processed into AutoBT and implanted in dorsal subcutaneous muscular tissues of 15 athymic mice. Biopsy samples were harvested at two, five, and eight weeks. The Bradford assay, sodium dodecyl sulphate polyacrylamide gradient gel, and western blotting were performed for investigation of organic contents of AutoBT. Results: Histology analyses showed signs of new bone formation as early as two weeks. Results of the Bradford assay indicated the existence of noncollagenous proteins (NCP). 0.29% (2.89 mg/g) of proteins were extracted by weight in the root portion of AutoBT; 0.02% (0.029 mg/g) and 1.79% (17.93 mg/g) of proteins were measured by weight in crown and block-form of AutoBT, respectively. However, recombinant human bone morphogenetic protein-2 was not observed in AutoBT. Conclusion: Within the limitation of the current study, AutoBT induced new bone formation by NCP embedded in dentin.

Shape Optimal Design by P-version of Finite Element Method (p-Version 유한요소법에 의한 형상 최적화설계)

  • Kim, Haeng Joon;Woo, Kwang Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.729-740
    • /
    • 1994
  • In the shape optimal design based on h-version of FEM, the ideal mesh for the initial geometry most probably will not be suitable for the final analysis. Thus, it is necessary to remesh the geometry of the model at each stage of optimization. However, the p-version of FEM appears to be a very attractive alternative for use in shape optimization. The main advantages are as follows; firstly, the elements are not sensitive to distortion for interpolation polynomials of order $p{\geq}3$; secondly, even singular problems can be solved more efficiently with p-version than with the h-version by proper mesh design; thirdly, the initial mesh design are identical. The 2-D p-version model for shape optimization is presented on the basis of Bezier's curve fitting, gradient projection method, and integrals of Legendre polynomials. The numerical results are performed by p-version software RASNA.

  • PDF

Reconstructive Procedures Combined with or Without Prosthetic Valve Replacement for Cardiac Valvular Lesions (심장판막 질환 성형술에 대한 임상적 고찰)

  • Kim, Y.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.207-214
    • /
    • 1976
  • Operations for cardiac valvular disease has been progressed in various ways. Since 1949 when Lord Russel operated mitral stenosis by closed technique at Johns Hopkins Hospital then much progress has been achieved and that nowadays severely diseased cardiac valve has been replaced by prosthetic valve, which is almost ideal in hemodynamic aspect, but still it has many problems such as thromboembolism, destruction of red blood cell, pressure gradient, and disturbance of left ventricular function, so in case of delicate situations, valve replacement should be decided carefully. Besides prosthetic valve, there are some kinds of reconstructive procedures and these have been resulted in better prognosis than prosthetic valve replacement in selected cases. So, authors have reviewed 61 Cases of cardiac patients who have been operated reconstructive valvular surgery by cardiopulmonary bypass, at Yonsei University, from Jan. 1963 to Mar. 1976. Out of 61 cases, 9 patients were replaced by prosthetic valve and rest of the patients were operated upon in various reconstructive procedures such as commissurotomy, valvotomy, valvuloplasty, and annuloplasty. Twenty cases of congenital heart diseases with valvular lesion, which had been operated for valvular lesion were also included in this statistics. Out of 9 cases of prosthetic valvular replacement five cases of prosthetic valvular replacement was done combined with other reconstructive procedures after attempted valvuloplasty. Comparative prognosis of both procedures are somewhat variable by reporters, average 19% of mortality after reconstructive surgery and 38% of mortality after prosthetic valve replacement in long term results. Most common cause of death in postoperative period was low output syndrome in both cases. It seems that good preoperative evaluation and proper reconstructive surgery will afford good prognosis in selected cardiac valvular diseased patient.

  • PDF

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.

Rapid Detection Methods for Food-Borne Pathogens in Dairy Products by Polymerase Chain Reaction (PCR 방법을 이용한 우유 및 유제품에서 발생하는 식중독 균의 신속 검출법)

  • Kwak, Hyelim;Han, Seonkyeong;Kim, Eiseul;Hong, Yeun;Kim, Haeyeong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.31 no.2
    • /
    • pp.171-177
    • /
    • 2013
  • The dairy industry has consistently grown via the expansion of dairy-based food categories. Dairy product consumption is stable since the nutrient composition in dairy products is ideal for human health. However, dairy products are highly susceptible to food-borne pathogens. Controlling the safety of dairy products is thus important when considering the nutrient-rich matrix of this food category. Currently, immunoassays or molecular biology techniques have been used to evaluate the safety of dairy products in Korea. These methods are based on the detection of proteins and thus have low reproducibility and sensitivity. Recent techniques to detect food-borne pathogens have focused on genetic analyses. Rapid detection methods for food-borne pathogens in milk and dairy products using polymerase chain reaction (PCR) techniques, such as conventional PCR, real-time PCR, repetitive sequence-based (rep)-PCR, PCR-denaturing gradient gel electrophoresis (DGGE), and digital PCR, are reviewed in this article. The aim of this review was to contribute knowledge of the relationship between microflora and the quality of dairy products. This study will also assist in the immediate monitoring of food-borne pathogens in milk and dairy products when an outbreak related to this food category occurs.

  • PDF

The effects of the thickness variation on the propagation of Lamb waves in a composite plate (복합재 평판의 두께변화가 램파의 전파에 미치는 영향)

  • 한정호;김천곤
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.29-34
    • /
    • 2006
  • This study experimentally investigates the characteristics of Lamb wave propagating in a composite plate of varied thickness. In practical aerospace structures, there are so many parts that have varied thickness. Therefore, in order to employ the Lamb wave in a structural health monitoring of those parts, it is necessary to understand correctly the characteristics of Lamb wave for the structure with thickness variation. Thin surface-bonded piezoelectric transducers, which have great potential in integrated monitoring systems for structural health, were used to generate and receive Lamb waves. The predicted propagation velocity under the assumptions of ideal mode conversions was compared with the experimentally measured one. The validity of the results was supported by the frequency analysis of the signals. Consequently, the results show that the transient region is occurred when Lamb waves propagate across the region that thickness variation over some gradient exists.

New Protein Extraction/Solubilization Protocol for Gel-based Proteomics of Rat (Female) Whole Brain and Brain Regions

  • Hirano, Misato;Rakwal, Randeep;Shibato, Junko;Agrawal, Ganesh Kumar;Jwa, Nam-Soo;Iwahashi, Hitoshi;Masuo, Yoshinori
    • Molecules and Cells
    • /
    • v.22 no.1
    • /
    • pp.119-125
    • /
    • 2006
  • The rat is an accepted model for studying human psychiatric/neurological disorders. We provide a protocol for total soluble protein extraction using trichloroacetic acid/acetone (TCA/A) from rat (female) whole brain, 10 brain regions and the pituitary gland, and show that two-dimensional gel electrophoresis (2-DGE) using precast immobilized pH (4-7) gradient (IPG) strip gels (13 cm) in the first dimension yields clean silver nitrate stained protein profiles. Though TCA/A precipitation may not be "ideal", the important choice here is the selection of an appropriate lysis buffer (LB) for solubilizing precipitated proteins. Our results reveal enrichment of protein spots by use of individual brain regions rather than whole brain, as well as the presence of differentially expressed spots in their proteomes. Thus individual brain regions provide improved protein coverage and are better suited for differential protein detection. Moreover, using a phosphoprotein-specific dye, ingel detection of phosphoproteins was demonstrated. Representative high-resolution silver nitrate stained proteome profiles of rat whole brain total soluble protein are presented. Shortcomings apart (failure to separate membrane proteins), gel-based proteomics remains a viable option, and 2-DGE is the method of choice for generating high-resolution proteome maps of rat brain and brain regions.