• 제목/요약/키워드: glass-to-glass bonding

검색결과 382건 처리시간 0.023초

Spin-on Glass를 이용한 실리콘과 유리의 저온 접합 공정 (Low Temperature Bonding Process of Silicon and Glass using Spin-on Glass)

  • 이재학;유중돈
    • Journal of Welding and Joining
    • /
    • 제23권6호
    • /
    • pp.77-86
    • /
    • 2005
  • Low temperature bonding of the silicon and glass using the Spin-on Glass (SOG) has been conducted experimentally to figure out the effects of the SOG solution composition and process variables on bond strength using the Design of Experiment method. In order to achieve the high quality bond interface without rack, sufficient reaction time of the optimal SOG solution composition is needed along with proper pressure and annealing temperature. The shear strength under the optimal SOG solution composition and process condition was higher than that of conventional anodic bonding and similar to that of wafer direct bonding.

유리-유리 진공-정전 열 접합을 이용한 PDP의 Tubeless 패키징 공정 (PDP Tubeless Packaging Process Using Glass-to-Glass Vacuum-Electrostatic Bonding)

  • 주병권;이덕중
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권1호
    • /
    • pp.37-40
    • /
    • 2001
  • New package process for PDP was proposed based on the glass-to-glass vacuum-electrostatic bonding process and tubeless packaging concept derived from the previous study. Hermeticity and operating performance of PDP test panel through the seal-off process application and the possibility for practical use might be high if the process simplicity and productivity-related effort was sequentially carried out.

  • PDF

Tubeless Packaging된 Field Emission Display의 개발 (Development of Tubeless-Packaged Field Emission Display)

  • 주병권;이덕중;이윤희;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.275-280
    • /
    • 1999
  • The glass-to-glass electrostatic bonding process in vacuum environment was developed and the tubeless-packaged FED was fabricated based on the bonding process. The fabricated tubeless-packaged FED showed stable field emission characteristics and potential applicability to the FED tubeless packaging and vacuum in-line sealing.

  • PDF

광중합형 Glass Ionomer Cement의 표면처리 방법에 따른 복합레진과의 결합력에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN WITH THE VARIOUS SURFACE TREATMENTS OF LIGHT - CURED GLASS IONOMER CEMENTS)

  • 용승희;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.421-430
    • /
    • 1992
  • The purpose of this study was to evaluate the bond strength between the composite resin and light - cured glass ionomer cement base / liners treated by the several methods. The light - cured glass ionomer cement(Vitrebond / Cavalite) were injected into cavites prepared in acrylic plates. One hundred and twenty specimens were uniformly prepared and devided into 3 groups. For the first group, primer was not applied to glass ionomer cement. For the second group, no application of primer was undertaken and light - curing procedure to uncured glass ionomer cement surface which was covered by bonding agent was undertaken. After bonding composite resin to light - cured glass ionomer surface, the specimens, were stored in $37^{\circ}C$, 100% humidity for 1 hour. The following results were obtained : 1. The omission of application of a primer did not produce a significantly poorer bond strength. 2. Light - curing technique to uncured glass ionomer cement which was covered by bonding agent did not produce a significantly poorer bonding strength. 3. The bond strength of Cavalite to composite resin was significantly higher than that of Vitrebond. 4. There was no significant difference between two different types of composite materials(Silux-Plus / Herculite XR) when it was applied to bond to glass ionomer cement.

  • PDF

접합유리와 반응된 Fe-Hf-N/Cr/SiO2 박막의 연자기 특성 열화 (Degradation of Soft Magnetic Properties of Fe-Hf-N/Cr/SiO2 Thin Films Reacted with Bonding Glass)

  • 제해준;김병국
    • 한국재료학회지
    • /
    • 제14권11호
    • /
    • pp.780-785
    • /
    • 2004
  • The degradation mechanism of soft magnetic properties of $Fe-Hf-N/Cr/SiO_2$ thin films reacted with a bonding glass was investigated. When $Fe-Hf-N/Cr/SiO_2$ films were annealed under $600^{\circ}C$ without the bonding glass, the compositions and the soft magnetic properties of Fe-Hf-N layers were not changed. However, after reaction with the bonding glass at $550^{\circ}C$, the soft magnetic properties of the film were degraded. At $600^{\circ}C$, the saturation magnetization of the reacted film decreased to 13.5 kG, and its coercivity increased to 4 Oe, and its effective permeability decreased to 700. It was founded that O diffused from the glass into the Fe-Hf-N layers during the reaction and generated $HfO_2$ phases. It was considered that the soft magnetic properties of the $Fe-Hf-N/Cr/SiO_2$ films reacted with the bonding glass were primarily degraded by the formation of the Fe-Hf-O-N layer of which the Fe content was below 60 $at\%$, and secondarily degraded by the Fe-Hf-O-N layer above 70 $at\%$.

유리-유리 정전접합을 이용한 FED스페이서 기술 개발 (Development of spacer technology using glass to glass anodic bonding for FED)

  • 김민수;박세광;문권진;김관수;우광제;정성재;이남양
    • 한국진공학회지
    • /
    • 제8권4A호
    • /
    • pp.465-469
    • /
    • 1999
  • In this paper, spacer process for FED (Field Emission Display ) was developed with the glass to glass anodic bonding technology using Al film as an interlayer. Characteristics, current density-time curves and force of the anodic boding were measured on various thickness of Al film; 1000$\AA$, 2000$\AA$, 3000$\AA$, 4000$\AA$ and 500$\AA$. Holders for spacer were fabricated with photosensitive glass and (110) Si wafer by bulk micromachining. Spacers was formed on glass substrate by spacer glass to glass anodic bonding and an evacuated panel was fabricated to prove the potential of application for FED.

  • PDF

유리/실리콘 기판 직접 접합에서의 세정과 열처리 효과 (Effects of Wafer Cleaning and Heat Treatment in Glass/Silicon Wafer Direct Bonding)

  • 민홍석;주영창;송오성
    • 한국전기전자재료학회논문지
    • /
    • 제15권6호
    • /
    • pp.479-485
    • /
    • 2002
  • We have investigated the effects of various wafers cleaning on glass/Si bonding using 4 inch Pyrex glass wafers and 4 inch silicon wafers. The various wafer cleaning methods were examined; SPM(sulfuric-peroxide mixture, $H_2SO_4:H_2O_2$ = 4 : 1, $120^{\circ}C$), RCA(company name, $NH_4OH:H_2O_2:H_2O$ = 1 : 1 : 5, $80^{\circ}C$), and combinations of those. The best room temperature bonding result was achieved when wafers were cleaned by SPM followed by RCA cleaning. The minimum increase in surface roughness measured by AFM(atomic force microscope) confirmed such results. During successive heat treatments, the bonding strength was improved with increased annealing temperatures up to $400^{\circ}C$, but debonding was observed at $450^{\circ}C$. The difference in thermal expansion coefficients between glass and Si wafer led debonding. When annealed at fixed temperatures(300 and $400^{\circ}C$), bonding strength was enhanced until 28 hours, but then decreased for further anneal. To find the cause of decrease in bonding strength in excessively long annealing time, the ion distribution at Si surface was investigated using SIMS(secondary ion mass spectrometry). tons such as sodium, which had been existed only in glass before annealing, were found at Si surface for long annealed samples. Decrease in bonding strength can be caused by the diffused sodium ions to pass the glass/si interface. Therefore, maximum bonding strength can be achieved when the cleaning procedure and the ion concentrations at interface are optimized in glass/Si wafer direct bonding.

복합레진과 Glass Ionomer Cement수복물에 대한 Bracket의 접착전단강도 (THE SHEAR BOND STRENGTH OF TWO ADHESIVES BONDED TO COMPOSITE RESIN AND GLASS IONOMER CEMENT RESTORATIONS)

  • 한재익;이병태
    • 대한치과교정학회지
    • /
    • 제20권3호
    • /
    • pp.583-591
    • /
    • 1990
  • If the bond strength is sufficient to resist orthodontic force, orthodontic brackets can be bonded to restorations. Orthodontic brackets were bonded to composite resin and glass ionomer cement restorations with no-mix adhesive or glass ionomer cement. The shear bond strength of adhesives bonded to restorations was studied in vitro. Orthodontic brackets were bonded to 10 extracted natural teeth, 40 composite resin restorations and 40 glass ionomer restorations. The surfaces of composite resin restorations were roughened or applied with bonding agent (Scothbond) after surface roughening. The surfaces of glass ionomer cement restorations were conditioned with acid etching or applied with Scotchbond to etched surface. The adhesive was no-mix resin or glass ionomer cement. The shear bond strength was measured. The results were as follows: 1. Orthodontic brackets could be bonded to composite resin restorations effectively as they could be bonded to acid etched enamel with no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was not affected by bonding agent greatly. 2. The shear bond strength of no-mix adhesive bonded to acid etched glass ionomer cement restorations was sufficient to resist orthodontic force. However. the fracture risk of glass ionomer cement restorations was increased during debonding. The bonding agent couldn't increase the shear bond strength greatly. 3. The shear bond strength of glass ionomer cement bonded to glass ionomer cement restorations was lower than that of no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was greatly decreased by bonding agent. 4. The shear bond strength of glass ionomer cement bonded to composite resin restorations was too low to resist orthodontic force.

  • PDF

유리-유리 기판의 진공-정전 열 접합 특성 (Vacuum-Electrostatic Bonding Properties of Glass-to-Glass Substrates)

  • 주병권;이덕중;이윤희
    • 마이크로전자및패키징학회지
    • /
    • 제7권1호
    • /
    • pp.7-12
    • /
    • 2000
  • 유리 프릿과 유리 튜브를 사용하지 않고 FED, VFD와 PDP를 봉입할 수 있는 기반 기술로서, 진공 내에서 두 장의 sodalite유리 기판들을 정전 열 접합하는 공정을 연구하였으며, 대기 중에서 정전 열 접합한 기판 쌍들과 비교하여 접합 특성을 비교.분석하였다. 진공 분위기 내에서 비정질 실리콘 interlayer를 이용하여 접합된 유리 기판 쌍의 경우, 대기압의 경우와 비교할 때 동일한 접합 온도와 전압에서 접합 강도가 상대적으로 낮은 것으로 측정되었으며, 산소 분위기의 경우 접합 강도가 증가하였음을 확인하였다. XPS와 SIMS를 통한 비정질 실리콘 표면 및 유리기판 표면의 조성 변화 분석으로부터, 진공내에서 산소가 부족함으로써 정전 열 접합 과정에서 부가적으로 수반되는 실리콘 산화막이 불완전하게 형성된 것으로 해석 할 수 있다.

  • PDF

3중 접합 공정에 의한 MEMS 공진기의 웨이퍼레벨 진공 패키징 (Wafer-level Vacuum Packaging of a MEMS Resonator using the Three-layer Bonding Technique)

  • 양충모;김희연;박종철;나예은;김태현;노길선;심갑섭;김기훈
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.354-359
    • /
    • 2020
  • The high vacuum hermetic sealing technique ensures excellent performance of MEMS resonators. For the high vacuum hermetic sealing, the customization of anodic bonding equipment was conducted for the glass/Si/glass triple-stack anodic bonding process. Figure 1 presents the schematic of the MEMS resonator with triple-stack high-vacuum anodic bonding. The anodic bonding process for vacuum sealing was performed with the chamber pressure lower than 5 × 10-6 mbar, the piston pressure of 5 kN, and the applied voltage was 1 kV. The process temperature during anodic bonding was 400 ℃. To maintain the vacuum condition of the glass cavity, a getter material, such as a titanium thin film, was deposited. The getter materials was active at the 400 ℃ during the anodic bonding process. To read out the electrical signals from the Si resonator, a vertical feed-through was applied by using through glass via (TGV) which is formed by sandblasting technique of cap glass wafer. The aluminum electrodes was conformally deposited on the via-hole structure of cap glass. The TGV process provides reliable electrical interconnection between Si resonator and aluminum electrodes on the cap glass without leakage or electrical disconnection through the TGV. The fabricated MEMS resonator with proposed vacuum packaging using three-layer anodic bonding process has resonance frequency and quality factor of about 16 kHz and more than 40,000, respectively.