• 제목/요약/키워드: glass window

검색결과 225건 처리시간 0.021초

AN EVALUATION OF ENERGY PERFORMANCE IN SUPER HIGH-RISE APARTMENT HOUSING WITH EXTERIOR WINDOW TYPES

  • Sang-Ho Lee;Yong-Ho Park;Jong-Chan Lee
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1637-1642
    • /
    • 2009
  • This study evaluates the energy performance of super high-rise residential buildings with e-QUEST simulation and calculates the annual cooling and heating load. The result of this study have concluded that the most influential factor is the characteristics of the window and also suggest the most efficient window system from the result of calculation of different glasses' cooling and heating load. The result of this study shows that The most efficient method to enhance the energy performance is to use low reflective 3 pairs Low-E glass and Low-E coating(inside of outer glass) pair glass.

  • PDF

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho;Mun, Sun-Hye
    • Architectural research
    • /
    • 제15권4호
    • /
    • pp.201-206
    • /
    • 2013
  • Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

A Comparative Analysis of the Energy Load due to Window Area Ratio of Domestic Public Buildings

  • An, Kwang-Ho;Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.21-27
    • /
    • 2015
  • In the case of public buildings, fast communication and transparency in the administration and the public, as well as ensuring visibility and lighting performance using a glass curtain wall is symbolically expressed through the transparent glass skin. This study is a simulation in order to derive the basic data for the establishment of the improvement of the heating and cooling load analysis according to the window area ratio changes with respect to the high effectiveness of the government's large public building energy consumption analysis and green building certification system of guidelines was analyzed by a change in the energy load. Glass curtain wall is light and visibility, the symbolic meaning of communication, etc., but is widely used in a variety of characteristics, in terms of energy consumption being disadvantaged sheath plan should have been. Design, including the Atrium, is much less energy than energy consumption by the window area ratio. Thus, while compliance with design guide lines, the atrium and I like the burden of a large space ratio and energy load consists of only glass suggest that require more research on that given in the guidelines.

고속열차 객실 유리창 충격파손특성 비교 연구 (A Study on Impact Damage Characteristics of the Window Glass for High Speed Train)

  • 전창성;김영국;윤수환;권혁빈;박태원
    • 한국철도학회논문집
    • /
    • 제15권3호
    • /
    • pp.217-223
    • /
    • 2012
  • 고속열차 객실 유리창 타입에 따른 충격 파손 특성을 비교 연구하기 위하여 다양한 종류의 유리창 내충격시험 규격을 검토하였으며, 자갈 비산에 의한 유리창 파손 특성을 고려하여 내충격시험을 실시하였다. 외부 충격면이 일반유리, 반강화유리, 강화유리 모두 팁 끝이 뾰족한 낙하체에 대해 낮은 높이에서도 파괴가 잘 일어났고, 파괴될 때의 양상은 일반유리의 경우 선 파괴가 부분적으로 발생하였고, 반강화유리의 경우 선 파괴가 전체적으로 발생하였으며, 강화유리의 경우 전체적으로 입자가 잘게 부숴지며 파괴되었다. 낙하체 팁 형상을 뾰족한 것에서부터 뭉툭한 것으로 변화시킬 때 더 높은 높이에서 파괴가 일어남을 알 수 있었고, 그 정도는 일반유리보다 강화유리가 팁 끝이 뭉툭한 낙하체에 대해서 더 높은 강도를 가짐을 알 수 있었다. 유리창 보호용 필름이 적용되었을 때 강도 증가의 효과가 있었다. 실제 자갈을 자유 낙하시켜 파손 특성을 비교하였는데, 3가지 경우 모두에 대해서 보호필름이 적용되지 않았을 때는 파괴되었고, 보호필름을 적용하였을 경우에는 잘 파괴되지 않음을 확인할 수 있었다.

유리창의 레이저 탐지음에 대한 음성명료도 분석 (Speech Intelligibility Analysis on the Laser Detected Sound of the Glass Windows)

  • 김석현;이현우;김희동
    • 한국음향학회지
    • /
    • 제28권2호
    • /
    • pp.127-134
    • /
    • 2009
  • 본 연구에서는 다양한 두께의 유리창을 대상으로 레이저 원격 도청 가능성을 검토한다. MLS 신호음을 사용하여 유리창을 진동시키고 레이저 도플러센서로 진동음을 탐지한다. 탐지된 진동음으로부터 음성정보의 인식 수준인 음성명료도를 객관적으로 평가한다. 평가에는 변조전송함수에 근거하여 결정되는 음성전송지수를 사용한다. 또한, 외부 스피커와 유리창 교란기로 각각 교란파를 발생시켜, 배경소음과 도청방지기의 음성명료도에 대한 교란효과를 평가한다. 다양한 두께의 유리창을 대상으로 레이저 원격 도청음의 음성인식 수준과 국산 도청 방지장치의 도청방지 성능을 평가하는 데에 본 연구의 목적이 있다.

이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석 (Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating)

  • 김효중;박재성;신우철;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF

고속철도차량용 창문유리의 압력시험에 관한 연구 (A study on the Pressure Test of the Glass Window for High Speed Train)

  • 장대성;이원
    • 한국철도학회논문집
    • /
    • 제14권5호
    • /
    • pp.391-397
    • /
    • 2011
  • 본 논문에서는 차세대 고속전철에 적용하기 위하여 개발한 객차용 창문의 압력시험에 관하여 연구 하였다. 열차 외부에 가장 큰 압력변동이 발생하는 시점이 터널내부에서 2개편성의 열차가 최고 속도로 서로 교행해서 지나갈 때이며 이때 발생 가능한 압력값을 부가할 수 있는 시험장비를 개발하여 NFF 31-314의 기준에 따라 시험을 수행하고 평가 하였다.

한국 철도차량 창호유리의 기능적 변천에 대한 고찰 (A study on the functional transition of Korean rolling stock's window pane.)

  • 이흥재;장대성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.323-337
    • /
    • 2009
  • This paper researched the adiabatic characteristic, safety and sound insulation characteristic of rolling stock window pane type and transition process of korean train vehicle window glass, and also including investigating a hereafter course of development. The window pane have provided the romantic feeling and the external scenery of train travel to the passenger in period of korea 110 year railway history. From the adiabatic viewpoint, this paper reviewed heat conductivity(U-value) and solar factor according to window pane type, including the safety and sound transmission loss of window pane.

  • PDF

고속철도차량의 유리창 압력에 관한 연구 (A Study on the Window Glass Pressure for High-speed Train)

  • 권혁빈;장대성
    • 한국철도학회논문집
    • /
    • 제13권4호
    • /
    • pp.371-375
    • /
    • 2010
  • 분산형 고속철도차량의 유리창 강도조건을 설정하기 위하여 열차가 터널을 통과하는 동안의 압력변동이 수치적으로 모사되었다. 계산결과를 토대로 객실 내외의 압력차이가 계산되었고, 객실 유리창에 작용하는 하중의 크기가 도출되었다. 열차가 터널을 통과하는 동안의 압력장을 모사하기 위하여 축대칭 Navier-Stokes 방정식에 기반한 전산유체역학이 이용되었다. 차량 내부의 압력변동은 차내 압력변화율과 차 내외부 압력변동의 선형 관계식에 근거한 1차 차분식을 이용하여 계산되었다.

창호의 차음성능에 관한 실험적 연구 (An Experimental Study on Transmission Loss of Window)

  • 이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.241-246
    • /
    • 2001
  • This study considered the transmission loss and frequency characteristecs of window, and examined the transmission loss for each type of windows to design an optimized window for blocking external noise. Moreover this has detect the transmission loss which depending on the thickness and the types(single and fair glass) of window as several major factors of transmission loss design. With this result, this study suggests a window design guide for much silent condition which is below the level of noise standard recommended.

  • PDF