• 제목/요약/키워드: geometric scattering

검색결과 43건 처리시간 0.024초

A NEW METHOD TO DETERMINE THE TEMPERATURE OF CMES USING A CORONAGRAPH FILTER SYSTEM

  • CHO, KYUHYOUN;CHAE, JONGCHUL;LIM, EUN-KYUNG;CHO, KYUNG-SUK;BONG, SU-CHAN;YANG, HEESU
    • 천문학회지
    • /
    • 제49권1호
    • /
    • pp.45-51
    • /
    • 2016
  • The coronagraph is an instrument that enables the investigation of faint features in the vicinity of the Sun, particularly coronal mass ejections (CMEs). So far coronagraphic observations have been mainly used to determine the geometric and kinematic parameters of CMEs. Here, we introduce a new method for the determination of CME temperature using a two filter (4025 Å and 3934 Å) coronagraph system. The thermal motion of free electrons in CMEs broadens the absorption lines in the optical spectra that are produced by the Thomson scattering of visible light originating in the photosphere, which affects the intensity ratio at two different wavelengths. Thus the CME temperature can be inferred from the intensity ratio measured by the two filter coronagraph system. We demonstrate the method by invoking the graduated cylindrical shell (GCS) model for the 3-dimensional CME density distribution and discuss its significance.

Novel Optical Properties of Si Nanowire Arrays

  • Lee, Munhee;Gwon, Minji;Cho, Yunae;Kim, Dong-Wook
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.179.1-179.1
    • /
    • 2014
  • Si nanowires have exhibited unique optical characteristics, including nano-antenna effects due to the guided mode resonance, significant optical absorption enhancement in wide wavelength and incident angle range due to resonant optical modes, graded refractive index, and scattering. Since Si poor optical absorption coefficient due to indirect bandgap, all such properties have stimulated proposal of new optoelectronic devices whose performance can surpass that of conventional planar devices. We have carried out finite-difference time-domain simulation studies to design optimal Si nanowire array for solar cell applications. Optical reflectance, transmission, and absorption can be calculated for nanowire arrays with various diameter, length, and period. From the absorption, maximum achievable photocurrent can be estimated. In real devices, serious recombination loss occurring at the surface states is known to limit the photovoltaic performance of the nanowire-based solar cells. In order to address such issue, we will discuss how the geometric parameters of the array can influence the spatial distribution of the optical field (resulting optical generation rate) in the nanowires.

  • PDF

완전도체 스트립 회절격자에 의한 E-분극 반사계수의 급속한 수염해 (The Fast Convergent Solution of E-Polarized Reflection Coefficient by a Perfect Conductor Strip Grating)

  • Uei-Joong Yoon
    • 한국전자파학회지:전자파기술
    • /
    • 제6권1호
    • /
    • pp.10-16
    • /
    • 1995
  • 완전도체 스트립 회절격자에 의한 E-분극 산문제를 모멘트법을 이용하여 해석하였다. E분극의 경우는 청도 되는 표면전류밀도가 모서리 양 끝에서 매우 높을 것으로 추측된다. 이때 스트립에 청도되는 표면전류밀도는 차수가 0인 Ultraspherical 다항식의 급수와 적절한 모서리 경계조건을 만족하는 함수의 곱의 급수로 전개하였다. 전류밀도와 반사계수에 대한수직결과를 기존의 다른 수틀과 비교하였다. 본 논문의 수치결과가 기존의 다른 수를 사용했을 때 보다 기하학적 반사계수의 경도가 매우 빠르게 향상됨을 보였다. 기하학적 반사계수에서의 급변점 위치는 입사각, 스트립 폭 및 스트립 주기를 변화시킴으로써 이동시킬 수 있었다.

  • PDF

코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성 (Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source)

  • 최태진;이호준;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.259-266
    • /
    • 1998
  • 코발트-60 근접조사선원을 대체할 Ir-l92 선원주변의 2차원적 선량분포를 얻기 위하여, 조사선량률과, 조직감쇠계수를 구하였다. 조직감쇠계수는 선원에서 20 cm 지점까지 실험식을 구하였다. ?보기 방사능은 조사선량상수를 사용하여 결정하였으며, 2.5mm 직경에 두께 2.5 mm 의 선원은 조직선량을 정하기 위해 선원을 4401 개로 분할하여 선원 자체의 흡수효과와 ?슐벽의 차폐 효과와 조직감쇠계수를 적용하였다. 조직감쇠계수는 4차식을 사용하여 1% 오차범위내에서 실험값을 얻을 수 있었으며, Meisberger 상수는 선원에서 많이 떨어질수록 오차가 커서, 10 cm 위치서 7%, 20 cm 에서 33%의 오차를 발견할 수 있었으나, 겉보기방사능과 선원모양 및 크기가 달라 다른 결과를 가져올 수 있다고 본다. 발표된 Ir-192 선원의 에너지스펙트럼을 이용한 선량률상수는 절삭에너지 10 keV인 경우 4.69 R$cm^2$/mCi-hr을 얻었으며 Air Kerma는 0.973 을 구하였다. 이 실험에서 고안 선원의 분할선원에 의한 선원자체흡수와 ?슐벽에 의한 감쇠는 실선원의 54.6%가 겉보기방사능으로 나타남을 알 수 있었으며, 선량계획에 이용하기 위해 단위 ?보기 방사능에 대한 2차원적 선량표를 준비함으로써 기하학적선량과 선량 비등방성을 쉽게 이용할 수 있도록 하였다.

  • PDF

효율적 다중경로 전파 예측을 위한 Ray-Tracing의 개선된 벡터 표현법 (An efficient multipath propagation prediction using improved vector representation)

  • 이상호;강선미;고한석
    • 한국통신학회논문지
    • /
    • 제24권12A호
    • /
    • pp.1974-1984
    • /
    • 1999
  • 본 논문은 정확한 전파 모델과 신속한 전파 예측 모델을 필요로 하는 다중 경로 현상을 효과적으로 획득하기 위해 효율적인 데이터 표현 구조를 제안한다. 본 논문은 ray tracing에서 사용되고 있는 VR(Vector Representation)을 향상시키기 위한 데이터 표현 구조로서, 빌딩과 같은 오브젝트를 표현하기 위해 CR(Circular Representation)을 이용하는 오브젝트 표현 방법을 제안한다. 제안된 CR은 건물의 중심에서 건물을 둘러싸도록 원을 그리는 형태이다. 본 구성에서 CR은 기하학적 구조를 위한 기본 빌딩 구조로서의 기능을 가지며, VR이 단독으로 사용되어 졌을 때 보다 더 많은 효율성을 증진시킨다. VR은 건물을 표현하기 위해 여러 개의 벽면 벡터를 필요로 하는 반면, CR은 하나의 원으로 표현된다. 결과적으로 제안된 방법에 의해 ray tracing에서 상당한 양의 계산 비용을 줄일 수 있다. 본 논문의 목표는 효율적인 ray tracing 예측 모델을 위해 데이터 구조화 시에 효율성을 얻기 위한 해결책으로서 CR을 제안하는 것이다. 본 논문은 제안된 방법에 의해 계산 부하량이 현저하게 줄어듬을 보인다. 또한 deterministic ray tracing 모델에서 CR의 계층? 구조의 수반 가능한 사용을 보인다. 시뮬레이션 결과는 계층적 octree 구조가 약 50% 계산 부하를 감소시키고 있는 반면 본 논문에서 제안된 CR은 분산된 물체의 수에 비례하여 계산 부하량을 현저하게 감소시킨다는 것을 나타낸다.

  • PDF

TOWARD A NEXT GENERATION SOLAR CORONAGRAPH: DEVELOPMENT OF A COMPACT DIAGNOSTIC CORONAGRAPH FOR THE ISS

  • Cho, K.S.;Bong, S.C.;Choi, S.;Yang, H.;Kim, J.;Baek, J.H.;Park, J.;Lim, E.K.;Kim, R.S.;Kim, S.;Kim, Y.H.;Park, Y.D.;Clarke, S.W.;Davila, J.M.;Gopalswamy, N.;Nakariakov, V.M.;Li, B.;Pinto, R.F.
    • 천문학회지
    • /
    • 제50권5호
    • /
    • pp.139-149
    • /
    • 2017
  • The Korea Astronomy and Space Science Institute plans to develop a coronagraph in collaboration with National Aeronautics and Space Administration (NASA) and to install it on the International Space Station (ISS). The coronagraph is an externally occulted one-stage coronagraph with a field of view from 3 to 15 solar radii. The observation wavelength is approximately 400 nm, where strong Fraunhofer absorption lines from the photosphere experience thermal broadening and Doppler shift through scattering by coronal electrons. Photometric filter observations around this band enable the estimation of 2D electron temperature and electron velocity distribution in the corona. Together with a high time cadence (<12 min) of corona images used to determine the geometric and kinematic parameters of coronal mass ejections, the coronagraph will yield the spatial distribution of electron density by measuring the polarized brightness. For the purpose of technical demonstration, we intend to observe the total solar eclipse in August 2017 with the filter system and to perform a stratospheric balloon experiment in 2019 with the engineering model of the coronagraph. The coronagraph is planned to be installed on the ISS in 2021 for addressing a number of questions (e.g., coronal heating and solar wind acceleration) that are both fundamental and practically important in the physics of the solar corona and of the heliosphere.

레이더 신호의 감쇠특성을 고려한 일체식 콘크리트 교량 바닥판의 상태평가 방법 고찰 (A Study on the Integrity Assessment of Bare Concrete Bridge Deck based on the Attenuation of Radar Signals)

  • 이지영;최재진;김홍삼;박고은;최명진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.84-93
    • /
    • 2016
  • 전자기파가 콘크리트 교량 바닥판을 통과할 때 에너지 손실 메카니즘에 의해 신호의 감쇠가 발생하며, 이는 콘크리트의 상대유전율과 전도도, 그리고 지리적 산란 손실의 영향에 따른 것으로 알려져 있다. 본 연구에서는 건전한 콘크리트에 대해서는 레이더파의 감쇠가 상부철근의 깊이와 선형관계에 있다는 점에 착안하여, 일체식 콘크리트 교량 바닥판에서 상태평가 지표로서의 레이더파의 신호감쇠를 실 교량에 적용하여 그 유용성에 대해 검토하였다. 연구결과, 손상된 콘크리트 교량 바닥판에서는 건전한 상태에 비해 상대적으로 큰 감쇠가 일어나며, 레이더 수신파의 총감쇠량에서 반사체의 깊이에 대해 선형적 관계인 부분을 제거하고 난 보정감쇠량은 일체식 콘크리트 교량 바닥판의 상태평가에 유용한 것으로 나타났다. 실제 공용 중인 손상 교량 바닥판에 적용한 결과, 제안된 방법은 교면에서 상부철근까지의 콘크리트 상태를 신뢰성 있게 평가할 수 있으며, 특히, 일체식 바닥판의 주손상요인인 상부철근의 부식환경을 간접적으로 평가할 수 있는 것으로 판단된다.

서울시 지하철 객차내에서의 미세먼지 농도 평가 (A Study of PM levels in Subway Passenger Cabins in Seoul Metropolitan area)

  • 노영만;박화미;이철민;김윤신;박동선;김석원
    • 한국산업보건학회지
    • /
    • 제17권1호
    • /
    • pp.13-20
    • /
    • 2007
  • This study was performed to investigate the concentrations of PM($PM_{10}$, $PM_{2.5}$, $PM_{1}$) and it's affecting factors in the subway from line 1 to line 8 in Seoul metropolitan area, from Sep. 1 to 30, 2005. PM concentrations were measured at the entrances and centers in subway passenger cabins by a light scattering equipment. And the affecting factors to PM were estimated based on the number of passenger, door open and close and running area etc. The geometric means of $PM_{10}$, $PM_{2.5}$ and $PM_{1}$ concentration in Seoul subway passenger cabins were $214{\mu}g/m^3$, $86.6{\mu}g/m^3$ and $27.0{\mu}g/m^3$, respectively. These mean concentrations in subway carriage were higher when it ran on an underground track than on a ground track. And running time(7AM-9AM, 11AM-13PM, 6PM-8PM) significantly influenced to the concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_{1}$. Daily profile of $PM_{10}$ and $PM_{2.5}$, $PM_{1}$ expressed as an 10 minutes average, showed similar variation pattern over day period. In correlation analysis, significant relations among $PM_{10}$, $PM_{2.5}$ and $PM_{1}$ were detected(p〈0.01). In particular, correlation coefficient between $PM_{10}$and $PM_{1}$ was highly significant(r=0.94). Further study is needed to identity the sources of PM in subway cabins and to compare pollutants concentration among subway lines.

인체기관지내의 입자펄스 확산 실험 (Dispersion of Particle Pulse in Human Lung Airway)

  • 이진원;이동엽;추경호
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.511-518
    • /
    • 1998
  • 세기관지의 구조와 이상유무의 신속 정확한 측정을 위해 세계적으로 활발히 연구되고 있는 에어로졸볼러스기법을 확립하기 위하여, 호흡과정 중 흡기에 공급된 입자펄스가 호흡의 진행에 따라 인체기관지내에서 대류분산된 결과로 호기중 입자농도의 증가된 분포폭을 측정하는 장치를 개발하고 이를 이용한 검증실험을 수행하였다. 개발된 장치는 인체에 무해한 sebacic acid를 이용하여 평균입경이 1 $\mu$m이고 기하표준편차가 1.2정도인 임자를 $10^{9}$개/cc 정도의 고농도로 발생하고, 솔레노이드밸브를 이용하여 호흡중의 원하는 시점에 정확히 짧은 펄스형태로 입자를 공급하며, 레이저광산란을 이용하여 흡기와 호기중의 입자농도의 시간변화를 측정한다. 흡기중의 농도분포는 매우 매끈한 분포를 보임으로써 발생장치와 측정장치의 정강작동은 잘 검증되었다. 농도의 시간변화 측정치로부터 계산된 분산도를 1차원 대류확산방정식 이론치 및 외국에서 보고된 실험결과와 비교한 격과, 입자도달깊이에 따른 분산도의 변화에 대한 정성적인 실험결과는 이론치와 상당히 잘 일치하고 기존의 결과보다도 견과의 산포가 개선되었다. 다만 아직도 산포가 상당히 남아있어 개선의 여지를 가지고 있으며, 외국 결과와의 분산도의 타이는 신체조건의 타이 등으로 파악되었다. 산포도의 개선을 위해서는 호흡시에, 특히 최고농도점 부근에서, 호흡유량이 일정하게 유지되어야만 불규칙 이차파형의 형성을 방지하여 측정결과의 해석에 오차를 줄일 수 있음을 확인하였다.

  • PDF

루프-루프 전자탐사자료의 효과적인 2.5차원 역산 (An efficient 2.5D inversion of loop-loop electromagnetic data)

  • 송윤호;김정호
    • 지구물리와물리탐사
    • /
    • 제11권1호
    • /
    • pp.68-77
    • /
    • 2008
  • 2.5차원 전자탐사 적분방정식의 확장된 Born 근사해 또는 국소 비선형 근사에 기초하여 루프-루프 전자탐사 역산 알고리듬이 개발되었다 송수신 배열은 수평 동일면(HCP) 또는 수직 동일면(VCP) 방식이고, 다중 주파수 및 다중 송수신 간격을 포함할 수 있으며 PC에서 작동된다. 안정적이고 고해상도를 유지하는 역산이 가능하도록 변수분해 행렬과 Backus-Gilbert 분산 함수 분석을 통해 감도 분포의 함수로서의 공간적으로 변화하는 최적 Lagrange 곱수 결정 알고리듬을 포함하였다. HCP와 VCP 배열 자료가 지하 전기비저항 구조에 따라 서로 다른 감도를 가짐에 따라 동시 역산에서 안정성과 해상도에 영향을 미치게 되므로, 계산값과 측정값 차의 분산에 따라 가중치를 적용하는 방식을 도입하였다. 모델링 코드의 정확성은 통상적으로 루프-루프 전자탐사에서 사용하는 주파수 및 송수신 간격 범위에서 유한차분법에 의해 계산된 결과와의 비교를 통하여 증명되었다. 개발된 역산 알고리듬은 먼저 반무한 공간내 전도체 및 저항체가 포함된 모델에 대한 계산자료에 적용되어 성능이 입증되었다. 현장자료에 적용하고 그 결과 영상을 전기비저항 탐사자료에 대한 역산 결과와 비교하여, 의미있는 지하구조의 영상을 얻을 수 있음을 확인하였다.