• Title/Summary/Keyword: gas monitoring

Search Result 1,029, Processing Time 0.027 seconds

Mobile Sensor Velocity Optimization for Chemical Detection and Response in Chemical Plant Fence Monitoring (사업장의 경계면에서 화학물질 감지 및 대응을 위한 이동식 센서 배치 최적화)

  • Park, Myeongnam;Kim, Hyunseung;Cho, Jaehoon;Lulu, Addis;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.41-49
    • /
    • 2017
  • Recently, as the number of facilities using chemicals is increasing, the amount of handling is rapidly increasing. However, chemical spills are occurring steadily, and if large quantities of chemicals are leaked in time, they are likely to cause major damage. These industrial complexes use information obtained from a number of sensors to detect and monitor leaking areas, and are used in industrial fields by applying existing fixed sensors to robots and drones. Therefore, it is necessary to propose a sensor placement method at the interface for rapid detection and response based on various leaking scenarios reflecting leaking conditions and environmental conditions of the chemical handling process. In this study, COMSOL was used to analyze the actual accident scenarios by applying the medium parameter to the case of chemical leaks. Based on the accident scenarios, the objective function is selected so that the velocity of each robot is calculated by attaching importance to each item of sensor detection probability, sensing time and sensing scenario number. We also confirmed the feasibility of this method of reliability analysis for unexpected leak accidents. Based on the above results, it is expected that it will be helpful to trace back the leakage source based on the concentration data of the portable sensor to be applied later.

The Estimation of Emission Factor of N2O and CH4 by Measurement from Stacks in the Waste Incinerators and Cement Production Plants

  • Choi, Sang-Min;Im, Jong-Kwon;Hong, Ji-Hyoung;Lee, Sue-Been;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.3
    • /
    • pp.217-226
    • /
    • 2007
  • The purpose of this study is to estimate the emission factor of $non-CO_2$ global warming gases such as $N_2O$ and $CH_4$ by measuring concentrations from stacks of waste incinerators and cement production plants. Based on the established monitoring methods, $N_2O$ concentration measured from stacks in incinerator were between 0.62 and $40.60\;ppm_v$ (ave. $11.50\;ppm_v$). The concentration of $N_2O$ was dependent on the incinerator types. However, the concentrations of $CH_4$ gas were between 2.65 and $5.68\;ppm_v$ (ave. $4.22\;ppm_v$), and did not show the dependency on the incinerator types. In the cement production plant, the concentration ranges of $N_2O$ from the stack were from 6.90 to $10.80\;ppm_v$ (ave. $8.60\;ppm_v$), and $CH_4$ were between 1.80 and $2.20\;ppm_v$ (ave. $2.60\;ppm_v$). Using measured concentrations, the emission amounts of $N_2O$ and $CH_4$ from stacks per year were calculated. The results were is 4.2 ton $N_2O/yr$ in the incinerators, and 53.7 ton $N_2O/yr$ in the cement facilities. The big difference is from the flow rate of flue gas in the cement facilities compared to the incinerators. By the same reason, the $CH_4$ emission amounts in cement plant and incinerator was found to be 339 ton $CO_2/yr$ and 34.1 ton $CO_2/yr$, respectively. Finally, the emission factor of $N_2O$ in the incinerators were calculated using the measured concentration and the amount of incinerated wastes, and was $42.5\sim799.1\;g/ton$ in kiln and stoker type, $11.9\sim79.9\;g/ton$ in stoker type, 90.1 ton/g in rotary kiln type, 174.9 g/ton in fluidized bed type, and 63.8 g/ton in grate type, respectively. Also, the emission factors of $CH_4$ were found to 65.2-91.3 g/ton in kiln/stoker type, 73.9-122 g/ton in stoker type, 109.5 g/ton rotary kiln, and 26.1 g/ton in fluidized bed type. This result indicates that the emission factor in incinerators is strongly dependent on the incinerator types, and matched with result of IPCC (International Panel on Climate Change) guideline.

A Study on CDM Possibility Assessment of Transport Sector (교통부문 청정개발체제(CDM) 사업화 가능성 평가)

  • Park, Jin Young;Kim, DongJun;Oh, Seung Hwoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.175-184
    • /
    • 2011
  • Transport sector takes charge of about 20 percent of energy consumption and GHG(Green House Gas) emission in Korea. One of the efficient strategy of reducing GHG is introducing CDM(Clean Development Mechanism), which is one of GHG reduction systems in Kyoto Protocol. Nowadays many tries have done to regist transport policies as CDM in transport sector, however, a lot of things should be investigated to regist CDM in advance. The aim of this paper is assessment of CDM possibility in transport sector. First of all, we review steps and criteria to CDM registration, and select 4 CDM possibility assessment index in transport sector: as follows additionality, methodology, emission calculation, and monitoring. Also, we analyze registed projects and methodologies in transport sector. To assess CDM possibility in transport sector, quantitative and qualitative assessments are carried out in this study. 18 transport policies are categorized as 4 groups and possibility of 18 transport policies are examined. Several policies can reduce GHG, however, they are not fit to regist as a CDM. On the contrary many transport policies have possibility to regist. In addition, we have done questionnaire survey, 'fuel change' policies have high possibility to CDM. However transport policies related to haman activity, like as TOD, have lower possibility. As a result, we can find that enough CDM possibility assessment should be carried out before CDM registration in transport sector.

Study on the Low Energy Sewage Management Based on Pre-sensing Technology and Automatic Blower Control (사전감지기술 및 송풍량 자동제어를 기반으로 한 저에너지 하수관리기술에 관한 연구)

  • Lee, Seungmyoung;Kim, Hanlae;Ki, Kyoungseo
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.592-603
    • /
    • 2019
  • This study is about the implementation of low energy sewage management technology through effective control of blower which consumes the most energy in sewage treatment. In calculating the amount of oxygen required for microorganisms, unlike the existing method using the operating index in the bioreactor or TMS data in the discharge port, the CODcr and NH4+-N concentration changes in sewage flowing into the sewage treatment plant were detected in advance before entering the bioreactor and the amount of air was controlled based on this. The pre-sensing was found to have a high correlation compared with conventional products. As a result of blower control, it was possible to save about 9.9% energy more than the manual control. Consequently, this study suggested the possibility of blower's real-time control combined with pre-sensing technology. Also, it is expected that the low energy sewage treatment can be applied to sewage treatment facilities dependent on operation by manpower, and it will contribute to the reduction of greenhouse gas emissions.

Comparison of the CO2 Emission Estimation Methods in a LNG Power Plant Based on the Mass Balance Approach (물질수지 방법을 고려한 액화천연가스 발전소에서의 온실기체 배출량 산정 방법 비교)

  • Kim, Hee-Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.235-244
    • /
    • 2013
  • Carbon dioxide emission estimation methods consist of four tiers according to the IPCC guideline. In this study, estimated results by tier 3 and tier 4 were compared with the theoretically calculated $CO_2$ emissions based on the mass balance approach for a gas fired power plant between March and May 2011. It was found that the relative differences were upto 17% between the measured emissions by tier 4 and theoretically estimated emissions, while the results of tier 3 were similar to those from theoretically estimated ones. The comparisons suggested the possibility of misestimation due to replacing missing, abnormal, or invalid data in continuous emissions monitoring system. When using only the data without those missing, abnormal, or invalid data, the relative differences decreased somewhat but still showed consistent differences depending on the stack. It is suggested that this differences might be due to the accuracy of the measurement instruments for the tier 4, especially, for the flow rate measurement instrument.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Development of Interlocking Signal Simulator for Verification of Naval Warship Engineering Control Logics (함정 통합기관제어체계의 제어로직 검증을 위한 연동신호 시뮬레이터 개발)

  • Lee, Hunseok;Son, Nayoung;Shim, Jaesoon;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1103-1109
    • /
    • 2021
  • ECS is a control device so that the warship can perform the mission stably by controlling and monitoring the entire propulsion system. As the recent provisions of the warship, it's propelling system is complicated than past, as the demand performance and mission of the warships are diverse. In accordance with the complicated propulsion system configuration, the demand for automatic control function of the ECS is increasing for convenient and stable propulsion system control for convenient and stable. As a result, verification of ECS stability and reliability is required. In this paper, we develop an interlocking signal simulator for verifying ECS control logic and communication protocol for warship with CODLOG propulsion systems. The simulator developed was implemented to simulate a signal of gas turbine, propulsion motors, diesel generator and 11 kinds of auxiliary equipment. The reliability of ECS was verified through the ECS communication program and the I/O signal static test with the simulator.

Determining the Aboveground Allometric Equations of Major Street Tree Species in Wonju, South Korea using the Nondestructive Stem Analysis Method (비파괴적 수간석해를 통한 원주시 주요 가로수 4수종의 지상부 상대생장식 개발)

  • Seungmin, Lee;Seonghun, Lee;Yewon, Han;Jeongmin, Lee;Yowhan, Son;Tae Kyung, Yoon
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.4
    • /
    • pp.502-510
    • /
    • 2022
  • In the national greenhouse gas inventory, a settlements category has never been included owing to the lack of activity data. Therefore, this study was conducted to obtain basic data for estimating biomass carbon storage in settlements. Nondestructive stem analysis with a laser dendrometer was performed on four major street tree species (Metasequoia glyptostroboides, Prunus armeniaca, Ginkgo biloba, and Acer buergerianum) in Wonju city, South Korea. Allometric equations of the aboveground volume were developed using five models, and allometric equations of crown area were developed with diameter at breast height (DBH) as an independent variable. The best performing allometric equations were aD2+bD+c for M.glyptostroboides and G. biloba, aD+bD2 for P. armeniaca, and a+bD2 for A. buergerianum. Regarding the allometric equations of crown area with DBH as an independent variable, G. biloba and A. buergerianum exhibited low coefficients of determination (R2), i.e., < 0.364, whereas M. glyptostroboides and P. armeniaca exhibited satisfactory R2 values, i.e., > 0.767, probably due to different street tree management practices. The allometricequations in this study will support the carbon inventory of settlements and urban tree monitoring in management practices.

Monitoring of Preservatives Produced Naturally in Vegetable Raw Materials (식물성 원료 중 천연유래 보존료의 함유량 조사)

  • Soo Bin Lee;Ji Sun So;Geum Jae Jeong;Hye Seon Nam;Jae Myeong Oh;Soon Ho Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.2
    • /
    • pp.152-162
    • /
    • 2024
  • In this study, we investigated the levels of the natural preservatives, benzoic acid, sorbic acid, and propionic acid, in raw unprocessed vegetables. Quantitative analysis of benzoic acid and sorbic acid was performed using high-performance liquid chromatography with a diode array detector (HPLC-DAD) and confirmed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Propionic acid was analyzed using a gas chromatography-flame ionization detector (GC-FID) and confirmed using gas chromatography-mass spectrometry (GC-MS). From a total of 497 samples, benzoic acid, sorbic acid, and propionic acid were found in 50 (10%), 8 (0.2%), and 61 samples (12.3%), respectively. The highest quantity of benzoic acid, sorbic acid, and propionic acid was found in peony root (1,057 mg/kg), nut-bearing torreya seeds (27.3 mg/kg), and myrrha (175 mg/kg), respectively. The background concentration range of naturally occurring preservatives in raw vegetables determined in this study could be used as standard inspection criteria to address consumer complaints and trade disputes.

A Study on Estimation of Air Pollutants Emission from Residential Wood Stove (주거용 화목난로의 대기오염 배출량 추정에 관한 연구)

  • Kim, Pil-Su;Jang, Young-Kee;Kim, Jeong;Shin, Yong-Il;Kim, Jeong-Soo;An, Jun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.276-285
    • /
    • 2010
  • Recently the Korean government has tried to cut down the $PM_{10}$ concentration by the Special Law for Air Quality Improvement. But the concentrations of $PM_{10}$ have exceeded the air quality standard at most monitoring stations. Primary $PM_{10}$ emitted from various sources and emission data have large uncertainty. The biomass burning is one of the major sources of $PM_{10}$ emission. The biomass burning is composed of wood stove usage, meat cooking and agricultural combustion etc.. Activity data and emission factors for the biomass burning are limited, and it is hard to calculate the air pollution emissions from these sources. In this study, we tried to estimate the air pollution emission from residential wood stove usage. The number of total wood stoves is estimated by the survey of wood stove manufacturer. And air pollution emission factors for the wood stove are investigated using the flue gas measurement by U.S. EPA particulate test method (Method 5G). As the results, the $PM_{10}$ and CO emission factors of wood stove are estimated as 7.7 g/kg-wood and 78.8 g/kg-wood respectively. The annual $PM_{10}$ and CO emissions from wood stove are calculated as 1,200~3,600 ton/year and 12,600~36,400 ton/year in Korea. It is confirmed that wood stove is the one of major sources of biomass burning, and the survey for activity data and the measurement for emission factors are needed for reducing the uncertainty of these emission data.