• Title/Summary/Keyword: gas analysis

Search Result 9,150, Processing Time 0.042 seconds

0.1 MW Test Bed CO2 Capture Studies with New Absorbent (KoSol-5) (신 흡수제(KoSol-5)를 적용한 0.1 MW급 Test Bed CO2 포집 성능시험)

  • Lee, Junghyun;Kim, Beom-Ju;Shin, Su Hyun;kwak, No-Sang;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.391-396
    • /
    • 2016
  • The absorption efficiency of amine $CO_2$ absorbent (KoSol-5) developed by KEPCO research institute was evaluated using a 0.1 MW test bed. The performance of post-combustion technology to capture two tons of $CO_2$ per day from a slipstream of the flue gas from a 500 MW coal-fired power station was first confirmed in Korea. Also the analysis of the absorbent regeneration energy was conducted to suggest the reliable data for the KoSol-5 absorbent performance. And we tested energy reduction effects by improving the absorption tower inter-cooling system. Overall results showed that the $CO_2$ removal rate met the technical guideline ($CO_2$ removal rate : 90%) suggested by IEA-GHG. Also the regeneration energy of the KoSol-5 showed about $3.05GJ/tonCO_2$ which was about 25% reduction in the regeneration energy compared to that of using the commercial absorbent MEA (Monoethanolamine). Based on current experiments, the KoSol-5 absorbent showed high efficiency for $CO_2$ capture. It is expected that the application of KoSol-5 to commercial scale $CO_2$ capture plants could dramatically reduce $CO_2$ capture costs.

Long-term Prognosis and Physiologic Status of Patients Requiring Ventilatory Support Secondary to Chest wall Disorders (흉벽질환에 의한 급성호흡부전 환자의 생리적 특성과 장기적인 예후)

  • Yoon, Seok Jin;Jun, Hee Jung;Kim, Yong Joo;Lee, Seung Jun;Kim, Eun Jin;Cha, Seung Ick;Park, Jae Yong;Jung, Tae Hoon;Kim, Chang Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.3
    • /
    • pp.265-272
    • /
    • 2006
  • Background: Chest wall deformities such as kyphoscoliosis, thoracoplasty, and fibrothorax cause ventilatory insufficiency that can lead to chronic respiratory failure, with recurrent fatal acute respiratory failure(ARF). This study evaluated the frequency and outcome of ARF, the physiologic status, and the long-term prognosis of these patients. Methods: Twenty-nine patients with chest wall disorders, who experienced the first requirement of ventilatory support from ARF were examined. The mortality and recurrence rate of ARF, the pulmonary functions with arterial blood gas analysis, the efficacy of home oxygen therapy, and the long-term survival rate were investigated. Results: 1) The mortality of the first ARF was 24.1%. ARF recurred more than once in 72.7% of the remaining 22 patients, and overall rate of successful weaning was 73.2%. 2) Twenty-two patients who recovered from the first ARF showed a restrictive ventilatory impairment with a mean FVC and TLC of 37.2% and 62.4 % of predicted value, respectively, and a mean $PaCO_{2}$ of 57mmHg. Among the parameters of pulmonaty functions. the FVC(p=0.01) and VC(p=0.02) showed a significant correlation with the $PaCO_{2}$ level. 3) There were no significant differences between the patients treated with conservative medical treatment only and those with additional home oxygen therapy due to significant hypoxemia in the patients with recurrent ARF and the mortality. 4) The 1, 3, 5-year survival rates were 75%, 66%, and 57%, respectively, in the 20 patients who had recovered from the first ARF, excluding the two patients managed by non-invasive nocturnal ventilatory support. Conclusion: These results suggest that active ventilatory support should be provided to patients with ARF and chest wall disorders. However, considering recurrent ARF and weak effect of home oxygen therapy, non-invasive domiciliary ventilation is recommended in those patients with these conditions to achieve a better long-term prognosis.

Chemical Composition and Antiproliferative Activity of Supercritical Extract of Immature Citrus Peel in human cervical carcinoma HeLa cells (미성숙 감귤 과피 초임계 추출물의 성분 분석과 자궁암세포 성장억제효능)

  • Moon, Jeong Yong;Song, YeonWoo;Hyun, Ho Bong;KimCho, Somi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8836-8843
    • /
    • 2015
  • This study was performed to investigate the antiproliferative activities of supercritical extracts from phalsak(Citrus hassaku Hort ex Tanaka) and yeagam(Citrus iyo Hort. ex Tanaka) against human cervical carcinoma HeLa cells and the chemical compositions of the extracts. The anticancer properties of supercritical extracts were demonstrated using the MTT assay and Hoechst 33342 staining and the compositional analyses were conducted by using gas chromatography-mass spectrometry(GC-MS). The peel extracts of both species exhibited similar antiproliferative effect. The antiproliferative activity of the flesh extracts was not detected up to $400{\mu}g/mL$, whereas peel extracts of phalsak and yeagam reduced cell viability with 87.16% and 92.95% at $400{\mu}g/mL$, respectively. There was a dramatic increase of the apoptotic body formation in the cell treated with peel extracts while no apoptotic body formation detected in the cell treated with flesh extracts at 100, $200{\mu}g/mL$. By GC-MS analysis, 27 and 31 kinds of compounds identified in flesh and peel of phalsak, while 27 and 29 kinds of compounds were identified in flesh and peel of yeagam, respectively. 1,1,4,4-Tetramethyl-2-tetralone(20.86%), alloimperatorin(8.15%), limonene(11.23%), and auraptene(7.29%) were major in peel of phalsak, whereas limonene(22.19%), linalool(11.23%), and ${\gamma}$-sitosterol(9.12%) were major in peel of yeagam.

Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea (육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구)

  • Song J. I.;Yoo Y. H.;Jeong J. W.;Kim T. I.;Choi H. C.;Kang H. S.;Yang C. B.;Lee Y. Y.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventilation efficiency in an enclosed and conventional growing-finishing pig house. The experimental pigs were in winter and summer. The main results of the experiment are as follows : Then the air from planar slot inlet the pig house flow out through the sidewall outlet operated by exhaust fan(Gl). The second structure has an air input through the circular duct inlet are plated side the juncture of the entering wall and the air into the pig house flow out through the chimney and pit outlet are operated by exhaust fan(G2). Through the air into relay fan the pig house flow out through the curtains in sidewall(G3). Similarly, air comes in through the circular duct inlet are placed the air into the pig house flow out through the curtains in sidewall (G4). Air flow rate on the floor level which is the low part of pen and the living area of pigs in the G2 and G4 system during winter was measured at 0.2 to 0.3 m/s at the 0.5 to 0.6 m/s at the maximum ventilation efficiency. As for the results of detrimental gas(ammonia) concentration ratio analysis, while G2 and G4 system sustained of summer 13.3 $\~$ 16.6 ppm, winter 14.0 $\~$ 14.6 ppm level, Gl and G3 system sustained of summer 14.6 $\~$ 20.3 ppm, winter 20.3 $\~$ 25.0 ppm, and the latter one is lower than that of the G1 and G3 system.

  • PDF

The Polyneuropathy in Patients with Chronic Obstructive Pulmonary Disease (만성 폐쇄성 폐질환 환자들의 다발성 말초신경병변에 대한 연구)

  • Baek, Jong-Cheul;Myung, Jae-Il;Kang, Heon-Seok;Kim, Yeong-Rock;Youm, Houng-Roul;Ryeu, Hyung-Seun;Lee, Soong;Kim, Wan;Noh, Jean-Yee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.806-814
    • /
    • 1997
  • The incidence, type and distribution of polyneuropathy in patients with chronic obstructive pulmonary disease (COPD) were assessed and also analyzed the causative factors. Forty-four patients, mean age 66.1 years (42 male, 2 female), have been investigated with arterial gas analysis, pulmonary function test, clinical and electrodiagnostic studies. None of them had conditions known to affect the peripheral nervous system such as metabolic disorders or drugs. In a selected group of 44 patients, electrophysiological findings of polyneuropathy were found in 22 patients(50%), clinical polyneuropathy were diagnosed in 13 patients(9 patients were diagnosed by electrophysiological studies, 4 patients were normal by electrophysiological studies). These findings indicate that subclinical polyneuropathy(13 patients, 30%) more commonly occurs than clinical polyneuropathy(9 patients, 20%) in associated with COPD. In the patients with polyneuropathy, the lesions were predominant axonal degeneration, the changes were more involved in leg than arm, more frequently affected sensory fibers. We could not find etiologic factor to cause polyneuropathy in COPD patients.

  • PDF

A Study of Effect on Pulmonary Function of Pleural Effusion in Tuberculous pleurisy patients (결핵성 흉막염 환자에서 흉수가 폐기능에 미치는 영향에 대한 연구)

  • Yim, Jeong Yoon;Lee, Kee Hyun;Jung, Hye Kyung;Chang, Jung Hyun;Cheon, Seon Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.491-499
    • /
    • 1996
  • Background : Pleural effusion is a common disease in clinical practice but its effect on pulmonary function and altered pulmonary mechanics after removal of effusion are not still largely understood. Previous studies have shown that there is little or a relatively small improvement in pulmonary function and arterial blood oxygenation after therapeutic thoracentesis. The present study was designed to assess the effect on pulmonary function of pleural effusion and to test whether there was a significant improvement in pulmonary function and arterial oxygenation after thoracentesis and to observe long tenn effect after thoracentesis. Method : We examined flow-volume curve, body box and arterial blood gas analysis according to severity of effusion, present symptom, and symptom duration. Then, we measured changes of pulmonary function after thoracentesis and observed longterm effect after thoracentesis. Result: 1) Pleural effusion cause restrictive pulmonary insufficiency. Not only functional impairment of small airway but also large airway is provoked. 2) MMFR, FEV1, Raw, POz are earlier improved than FVC and TLC after thoracentesis and patients without complication have mild restrictive pulmonary insufficiency after longterm observation. 3) FVC, FEV1, & TLC are similarly restricted as severity of pleural effusion and po, is relatively decreased. 4) Cases with symptom duration 1 week or less and cases with dyspnea have more severe pulmonary insufficiency than others. 5) The flow volume curves show a relatively greater improvement in flow rates at large lung volumes than small airway. 6) Significant relationship is shown between first thoracentesis amount and changes of FEV1, FVC, TLC. Conclusion: Pleural effusion cause restrictive pulmonary insufficiency and not only functional impairment of small airway impairment but also large airway is provoked. Then, Pulmonary function is progressively improved after thoracentesis and remained mild restrictive pulmonary insufficiency after recovery.

  • PDF

Analysis of Physicochemical Characterization and Volatiles in Pure or Refined Olive Oils (국내 유통되는 퓨어 및 정제 올리브유의 이화학적 특성 및 향기 분석)

  • Nam, Ha-Young;Lee, Ju-Woon;Hong, Jang-Hwan;Lee, Ki-Teak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.11
    • /
    • pp.1409-1416
    • /
    • 2007
  • Seven selected commercial pure or refined olive oils were obtained from the market, and their physicochemical properties and volatile characterizations were investigated. Fatty acid profiles of the analyzed olive oils showed oleic $(61.2{\sim}74.7mole%)$, palmitic $(10.2{\sim}16.8mole%)$, linoleic $(9.4{\sim}18.0mole%)$, stearic $(1.9{\sim}3.0mole%)$, palmitoleic $(0.7{\sim}2.4mole%)$ and linolenic acid $(0.5{\sim}0.9mole%)$. According to Hunter#s color measurement, pure or refined olive oils showed $L^*$ value of $92.2{\sim}99.0$, $a^*$ value of $-22.2{\sim}-3.2$, and $b^*$ value of $18.5{\sim}55.0$. Their total phenol contents ranged from 1.9 to $13.3mg/100g$ while ${\alpha}-tocopherol$ content showed $7.91{\sim}13.88mg/100g$. Oxidation stability of the pure or refined olive oils were observed by Rancimat. The induction period ranged from 17.37 to 34.72 hr while their POV were $6.83{\sim}20.31meq/kg$ oil. Electronic nose and gas chromatograph-mass spectrometry with head-space solid phase microextraction were applied to identify and discriminate the volatile compounds and flavors in pure or refined olive oils, respectively.

The Optimal Pulse Oxygen Saturation in Very Low Birth Weight or Very Preterm Infants (극소 저체중 출생아에서 경피적 산소포화도의 적정 범위)

  • You, Sun-Young;Kang, Hye-Jin;Kim, Min-Jung;Chang, Mea-Young
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.320-327
    • /
    • 2011
  • Purpose: To determine the effect of changing practice guidelines designed to avoid hyperoxia or hypoxia in very low birth weight or very preterm infants. Methods: We analyzed a database of <1,500 g birth weight or <32 weeks of gestation infants who were born and admitted to the neonatal intensive care unit of Chungnam National University Hospital from January 2007 to July 2010. First, we defined the relationship between arterial partial pressure of oxygen ($PaO_2$) and pulse oxygen saturation ($SpO_2$). When we evaluated 96 pairs of $PaO_2$ and $SpO_2$ measurements, oxygen saturation was 90-94% at a $PaO_2$ of 43-79 mmHg on the oxyhemoglobin dissociation curve, according to pulse oximetry. Based on this observation, a change in practice was instituted in August 2008 with the objective of avoiding hypoxia and hyperoxia in preterm infants with targeting a $SpO_2$ 90-94% (period II). Before the change in practice, high alarms for $SpO_2$ were set at 100% and low alarms at 95% (period I). Results: Sixty-eight infants the met enrollment criteria and 38 (56%) were born during period II, after the change in $SpO_2$ targets. Demographic characteristics, except gender, were similar between the infants born in both periods. After correcting for the effect of confounding factors, the rates for mortality, severe retinopathy of prematurity, and IVH attended to be lower than those for infants in period II. No difference in the rate of patent ductus arteriosus needed to treat was observed. Conclusion: A change in the practice guidelines aimed at avoiding low oxygen saturation and hyperoxia did not increase neonatal complication rates and showed promising results, suggesting decreased mortality and improvements in short term morbidity. It is still unclear what range of oxygen saturation is appropriate for very preterm infants but the more careful saturation targeting guideline should be considered to prevent hypoxemic events and hyperoxia.

Comparison of Ventilation Efficiency in an Enclosed and Conventional Growing-Finishing Pig House (개방형과 무창형 육성비육돈사의 환기효율 비교)

  • Song, J.I.;Choi, D.Y.;Jung, J.W.;Yang, C.B.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.459-468
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventulation efficiency in an enclosed and conventional growing-finishing pig house. The main results of the experiment are as follows : In the established temperature was sustained at the level of summer 24.8${\sim}$29.1$^{\circ}C$, winter 17.9${\sim}$23.1$^{\circ}C$ during the experimental period of enclosed growing-finishing pig house, and conventional growing-finishing pig house was at the lovel of summer 24.7${\sim}$32.3$^{\circ}C$, winter 14.5${\sim}$18.2$^{\circ}C$ during the experimental period respectively. As for the results of dertimental gas(ammonia) concentration ratio analysis, while the conventional pig house sustained of summer 9.3${\sim}$16.9 mg/$\ell$ level, enclosed growing-finishing pig house sustained of summer 7.9${\sim}$16.1 mg/$\ell$, and the latter one is lower than that of the conventional growing-finishing pig house. Air flow rate on the floor level which is the low part of pen and the active area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.87 m/s at the 0.01 to 2.73 m/s at the maximum ventilation efficiency. As for breeding pigs in summer, the pigs from the conventional pig house weighed 100.2kg, on the other hand, the pigs from enclosed growing-finishing pig house weighed 107.3 kg ; the differnce between the two kinds was about 7 kg. This was because the most adequate environment, which was not influenced by the exterior atmosphere, was offered to the pigs from enclosed growing-finishing pig house, and all of this could reduce pigs stress effectively.

Estimation of Carbon Emission and Application of LCA (Life Cycle Assessment) from Barely (Hordeum vulgare L.) Production System (보리의 생산과정에서 발생하는 탄소배출량 산정 및 전과정평가 적용)

  • So, Kyu-Ho;Park, Jung-Ah;Lee, Gil-Zae;Ryu, Jong-Hee;Shim, Kyo-Moon;Roh, Kee-An
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.5
    • /
    • pp.722-727
    • /
    • 2010
  • This study was conducted to estimate the carbon footprint and to establish the database of the LCI (Life Cycle Inventory) for barely cultivation system. Barley production system was separated into the naked barley, the hulled barley and the two-rowed barley according to type of barley species. Based on collecting the data for operating LCI, it was shown that input of fertilizer was the highest value of 9.52E-01 kg $kg^{-1}$ for two-rowed braley. For LCI analysis focussed on the greenhouse gas (GHG), it was observed that carbon footprint were 1.25E+00 kg $CO_2$-eq. $kg^{-1}$ naked braley, 1.09E+00 kg $CO_2$-eq. $kg^{-1}$ hulled braley and 1.71E+00 $CO_2$-eq. $kg^{-1}$ two-rowed barley; especially two-rowed barley cultivation system had highest emission value as 1.09E+00 kg $CO_2$ $kg^{-1}$ barley. It might be due to emit from mainly fertilizer production for barley cultivation. Also $N_2O$ was emitted at 7.55E-04 kg $N_2O\;kg^{-1}$ barley as highest value from hulled barley cultivation system because of high N fertilizer input. The result of life cycle impcat assessment (LCIA), it was observed that most of carbon emission from barely cultivation system was mainly attributed to fertilizer production and cropping unit. Characterization value of GWP was 1.25E+00 (naked barley), 1.09E+00 (hulled barley) and 1.71E+00 (two-rowed barely) kg $CO_2$-eq. $kg^{-1}$, respectively.