• Title/Summary/Keyword: gamma-spectrometry

Search Result 208, Processing Time 0.032 seconds

Oxidation Products from the Mixture of $\alpha$-Tocopherol and ${\gamma}$-Tocopherol during Autoxidation of Methly Linoleate (Methyl Linoleate의 자동산화에 따른 $\alpha$-Tocopherol과 ${\gamma}$-Tocopherol 혼합계의 산화생성물)

  • 하귀현
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.3
    • /
    • pp.239-247
    • /
    • 1990
  • The oxidation products from the mixture of a-tocopherol (a-Toc) and γ-tocopherol)(γ-Toc) during autoxidation of methyl linoleate were isolated and identified. The sturctures of the oxida-tion products were characterized by UV, IR, 1H and 13CNMR and mass spectrometry 5-[2-(a-tocopherol-5'-yl)ethyl]-a-tocopherylquinone 5-[2-(a-tocopherol-5'-yl)ethyl]-8a-hydroxy-a-tocopherone and O-[8-(5-ethoxymethyl-7-methyltocol) methyl] a-tocopherol were obained from the mixture as the oxidation products derived from γ-Toc However oxidation product composed of both a-ToC and γ-Toc was detected in oxidation products of the misture. These results support the facts that at first oxidation of a-Toc proceeds during autoxidation of lipids and then γ-Toc decomposes after approximate consumption of a-Toc.

  • PDF

True coincidence summing correction factor for point source geometry with PHITS

  • Esra Uyar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4472-4476
    • /
    • 2023
  • In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/calculated in gamma-ray spectrometric studies.

Current Issues for the Material Balance Evaluation in NFFP

  • Na, Won-Woo;Park, Wan-Sou;Ahn, Seung-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.1447-1448
    • /
    • 2004
  • As the plants are classified as a bulk facility by the Agency's safeguards criteria, the Material Balance Evaluation is a good tool to timely detect diversion that will be accomplished through the creation of defects as small as bias defects. Through all evaluations made by the Agency, it Is strongly recommended to report SRD based on both weight and enrichment, maintain the reliable MUF declaration and improve the gamma spectrometry measurement procedure. These recommendations have been now applied and are going on.

  • PDF

Studies on the Essential Oil Components of Thymus magnus Nakai (섬백리향의 정유성분(精油成分))

  • Han, Dae-Suk;Kim, Kwang-Wook
    • Korean Journal of Pharmacognosy
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 1980
  • By means of prefractionation on a silicagel column and combination of GC-Mass spectrometry, the essential oil constituents of Thymus magnus Nakai were analysed. Ten terpenoid compounds, ${\gamma}-terpinene$, ${\alpha}-pinene$, ${\beta}-caryophyllene$, ${\beta}-bisabolene$, pcymene, 4-isopropyltropolone, thymol, carvacrol, terpinen-4-ol and Borneol, were identified by referring to the spectrums of their authentic specimens.

  • PDF

Development of Gas Chromatography/Mass Spectrometry for the Determination of Essential Fatty Acids in Food Supplemental Oil Products

  • Ahn, Seonghee;Yim, Yoon-Hyung;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.75-78
    • /
    • 2013
  • A gas chromatography/mass spectrometric (GC/MS) method was developed as a candidate reference method for the accurate determination of essential fatty acids (linoleic acid, ${\alpha}$- and ${\gamma}$-linolenic acids) in food supplemental oil products. Samples were spiked with three internal standards (stearic acid-$d_{35}$, $^{13}C_{18}$-linoleic acid, and $^{13}C_{18}$-${\alpha}$-linolenic acid). Samples were then subject to saponification, derivatization for methylation, and extraction by organic solvent. For GC/MS measurement, an Agilent HP-88 column, designed for the separation of fatty acid methyl esters, was selected after comparing with other columns as it provided better separation for target analytes. Target analytes and internal standards were detected by selected ion monitoring of molecular ions of their methyl ester forms. The GC/MS method was applied for the measurement of three botanical oils in NIST SRM 3274 (borage oil, evening primrose oil, and flax oil), and measurement results agreed with the certified values. Measurement results for target analytes which have corresponding isotope-labeled analogues as internal standard were calculated based on isotope dilution mass spectrometry (IDMS) approach, and compared with results calculated by using the other two internal standards. Results from the IDMS approach and the typical internal standard approach were in good agreement within their measurement uncertainties. It proves that the developed GC/MS method can provide similar metrological quality with IDMS methods for the measurement of fatty acids in natural oil samples if a proper fatty acid is used as an internal standard.

DETERMINATION OF THE TRANSURANIC ELEMENTS INVENTORY IN HIGH BURNUP PWR SPENT FUEL SAMPLES BY ALPHA SPECTROMETRY

  • Joe, Kih-Soo;Song, Byung-Chul;Kim, Young-Bok;Han, Sun-Ho;Jeon, Young-Shin;Jung, Euo-Chang;Jee, Kwang-Yong
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.673-682
    • /
    • 2007
  • The contents of transuranic elements in high-burnup spent fuel samples were determined. The activity amounts of $^{238}Pu,\;^{239}Pu,\;^{240}Pu,\;^{241}Am,\;^{244}Cm\;and\;^{242}Cm$ were measured by alpha spectrometry using $^{242}Pu\;and\;^{243}Am$ as tracers, respectively. A spike addition method for $^{237}Np$ was established by an alpha and gamma spectrometry using $^{239}Np$ as a spike after the optimum conditions for the measurements of $^{237}Np\;and\;^{239}Np$, respectively, were obtained. A separation system using anion exchange chromatography and diethylhexylphosphoric acid extraction chromatography was applied for the separation of these elements. This method was applied to high-burnup spent nuclear fuel samples $(40{\sim}60GWD/MTU)$. The contents of the transuranic elements were compared with those by ORIGEN-2 code. Measurements and the calculations of the contents of the plutonium isotopes $^{238}Pu,\;^{239}Pu\;and\;^{240}Pu$ agreed to within 10% on average. The contents of $^{237}Np$ agreed to within approximately 5% except for one instance of a calculation, while those of $^{241}Am,\;^{244}Cm\;and\;^{242}Cm$ showed higher values by approximately 19%, 35% and 14% on average, respectively, compared to the calculations according to the burnup.

Basic characterization of uranium by high-resolution gamma spectroscopy

  • Choi, Hee-Dong;Kim, Junhyuck
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.929-936
    • /
    • 2018
  • A basic characterization of uranium samples was performed using gamma- and X-ray spectroscopy. The studied uranium samples were eight types of certified reference materials with $^{235}U$ enrichments in the range of 1-97%, and the measurements were performed over 24 h using a high-resolution and high-purity planar germanium detector. A general peak analysis of the spectrum and the $XK_{\alpha}$ region of the uranium spectra was carried out by using HyperGam and HyperGam-U, respectively. The standard reference sources were used to calibrate the spectroscopy system. To obtain the absolute detection efficiency, an effective solid angle code, EXVol, was run for each sample. Hence, the peak activities and isotopic activities were determined, and then, the total U content and $^{234}U$, $^{235}U$, and $^{238}U$ isotopic contents were determined and compared with those of the certified reference values. A new method to determine the model age based on the ratio of the activities of $^{223}Ra$ and $^{235}U$ in the sample was studied, and the model age was compared with the known true age. In summary, the present study developed a method for basic characterization of uranium samples by nondestructive gamma-ray spectrometry in 24 h and to obtain information on the sample age.

Efficiency calibration and coincidence summing correction for a NaI(Tl) spherical detector

  • Noureddine, Salam F.;Abbas, Mahmoud I.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3421-3430
    • /
    • 2021
  • Spherical NaI(Tl) detectors are used in gamma-ray spectrometry, where the gamma emissions come from the nuclei with energies in the range from a few keV up to 10 MeV. A spherical detector is aimed to give a good response to photons, which depends on their direction of travel concerning the detector center. Some distortions in the response of a gamma-ray detector with a different geometry can occur because of the non-uniform position of the source from the detector surface. The present work describes the calibration of a NaI(Tl) spherical detector using both an experimental technique and a numerical simulation method (NSM). The NSM is based on an efficiency transfer method (ETM, calculating the effective solid angle, the total efficiency, and the full-energy peak efficiency). Besides, there is a high probability for a source-to-detector distance less than 15 cm to have pulse coincidence summing (CS), which may occur when two successive photons of different energies from the same source are detected within a very short response time. Therefore, γ-γ ray CS factors are calculated numerically for a 152Eu radioactive cylindrical source. The CS factors obtained are applied to correct the measured efficiency values for the radioactive volumetric source at different energies. The results show a good agreement between the NSM and the experimental values (after correction with the CS factors).

Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source

  • Badawi, Mohamed S.;Thabet, Abouzeid A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1421-1430
    • /
    • 2022
  • The computation of the solid angle and the detector efficiency is considering to be one of the most important factors during the measuring process for the radioactivity, especially the cylindrical γ-ray NaI(Tl) detectors nowadays have applications in several fields such as industry, hazardous for health, the gamma-ray radiation detectors grow to be the main essential instruments in radiation protection sector. In the present work, a generic numerical simulation method (NSM) for calculating the efficiency of the γ-ray spectrometry setup is established. The formulas are suitable for any type of source-to-detector shape and can be valuable to determine the full-energy peak and the total efficiencies and P/T ratio of cylindrical γ-ray NaI(Tl) detector setup concerning the truncated conical radioactive source. This methodology is based on estimate the path length of γ-ray radiation inside the detector active medium, inside the source itself, and the self-attenuation correction factors, which typically use to correct the sample attenuation of the original geometry source. The calculations can be completed in general by using extra reasonable and complicate analytical and numerical techniques than the standard models; especially the effective solid angle, and the detector efficiency have to be calculated in case of the truncated conical radioactive source studied condition. Moreover, the (NSM) can be used for the straight calculations of the γ-ray detector efficiency after the computation of improvement that need in the case of γ-γ coincidence summing (CS). The (NSM) confirmation of the development created by the efficiency transfer method has been achieved by comparing the results of the measuring truncated conical radioactive source with certified nuclide activities with the γ-ray NaI(Tl) detector, and a good agreement was obtained after corrections of (CS). The methodology can be unlimited to find the theoretical efficiencies and modifications equivalent to any geometry by essential sufficiently the physical selective considered situation.