Efficiency calibration and coincidence summing correction for a NaI(Tl) spherical detector  

Noureddine, Salam F. (Physics Department, Faculty of Science, Lebanese University)
Abbas, Mahmoud I. (Physics Department, Faculty of Science, Alexandria University)
Badawi, Mohamed S. (Physics Department, Faculty of Science, Alexandria University)
Publication Information
Nuclear Engineering and Technology / v.53, no.10, 2021 , pp. 3421-3430 More about this Journal
Abstract
Spherical NaI(Tl) detectors are used in gamma-ray spectrometry, where the gamma emissions come from the nuclei with energies in the range from a few keV up to 10 MeV. A spherical detector is aimed to give a good response to photons, which depends on their direction of travel concerning the detector center. Some distortions in the response of a gamma-ray detector with a different geometry can occur because of the non-uniform position of the source from the detector surface. The present work describes the calibration of a NaI(Tl) spherical detector using both an experimental technique and a numerical simulation method (NSM). The NSM is based on an efficiency transfer method (ETM, calculating the effective solid angle, the total efficiency, and the full-energy peak efficiency). Besides, there is a high probability for a source-to-detector distance less than 15 cm to have pulse coincidence summing (CS), which may occur when two successive photons of different energies from the same source are detected within a very short response time. Therefore, γ-γ ray CS factors are calculated numerically for a 152Eu radioactive cylindrical source. The CS factors obtained are applied to correct the measured efficiency values for the radioactive volumetric source at different energies. The results show a good agreement between the NSM and the experimental values (after correction with the CS factors).
Keywords
Spherical NaI(Tl) detector; Effective solid angle; Efficiency transfer method; Numerical analytical method; Coincidence summing factors;
Citations & Related Records
연도 인용수 순위
  • Reference
1 M.I. Abbas, M.S. Badawi, I.N. Ruskov, A.M. El-Khatib, D.N. Grozdanov, A.A. Thabet, et al., Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 771 (2015) 110-114, https://doi.org/10.1016/j.nima.2014.10.056.   DOI
2 M.M. Gouda, M.S. Badawi, A.M. El-Khatib, M.M. Mohamed, A.A. Thabet, M.I. Abbas, Calibration of well-type NaI(Tl) detector using a point sources measured out the detector well at different axial distances, J. Instrum. 10 (2015), https://doi.org/10.1088/1748-0221/10/03/p03022.   DOI
3 D. Novkovic, M. Durasevic, A. Kandic, I. Vukanac, B. Seslak, Z. Milosevic, Coincidence summing corrections for point and volume 152 Eu sources, Appl. Radiat. Isot. 107 (2016) 138-144, https://doi.org/10.1016/j.apradiso.2015.10.015.   DOI
4 M.M. Gouda, A. Hamzawy, M.S. Badawi, A.M. El-Khatib, A.A. Thabet, M.I. Abbas, Mathematical method to calculate full-energy peak efficiency of detectors based on transfer technique, Indian J. Phys. 90 (2015) 201-210, https://doi.org/10.1007/s12648-015-0737-1.   DOI
5 M.S. Badawi, I. Ruskov, M.M. Gouda, A.M. El-Khatib, M.F. Alotiby, M.M. Mohamed, et al., A numerical approach to calculate the full-energy peak efficiency of HPGe well-type detectors using the effective solid angle ratio, J. Instrum. 9 (2014), https://doi.org/10.1088/1748-0221/9/07/p07030.   DOI
6 D. Al Oraini, Calibration of the absolute efficiency of well-type NaI(Tl) scintillation detector in 0.121-1.408 MeV energy range, Sci. Technol. Nuclear Install. (2018) 1-6, https://doi.org/10.1155/2018/6432380.   DOI
7 H.-X. Shi, B.-X. Chen, T.-Z. Li, D. Yun, Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector, Appl. Radiat. Isot. 57 (2002) 517-524, https://doi.org/10.1016/s0969-8043(02)00140-9.   DOI
8 Y. Mian, D. Jie, W. Shan, Y. Zhang, C. Ma, A nuclear density probe: isobaric yield ratio difference, Nucl. Sci. Tech. 26 (2015), S20503, https://doi.org/10.13538/j.1001-8042/nst.26.S20503.   DOI
9 M.I. Abbas, S. Noureddeen, Analytical expression to calculate total and full-energy peak efficiencies for cylindrical phoswich and lanthanum bromide scintillation detectors, Radiat. Meas. 46 (2011) 440-445, https://doi.org/10.1016/j.radmeas.2011.01.017.   DOI
10 J.C. Aguiar, An analytical calculation of the peak efficiency for cylindrical sources perpendicular to the detector axis in gamma-ray spectrometry, Appl. Radiat. Isot. 66 (2008) 1123-1127, https://doi.org/10.1016/j.apradiso.2007.12.007.   DOI
11 L. Moens, J. De Donder, L. Xi-lei, F. De Corte, A. De Wispelaere, A. Simonits, et al., Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries, Nucl. Instrum. Methods Phys. Res. 187 (1981) 451-472, https://doi.org/10.1016/0029-554x(81)90374-8.   DOI
12 A. El-Khatib, A. Thabet, M. Elzaher, M. Badawi, B. Salem, Study on the effect of the self-attenuation coefficient on γ-ray detector efficiency calculated at low and high energy regions, Nuclear Eng. Technol. 46 (2014) 217-224, https://doi.org/10.5516/net.04.2013.077.   DOI
13 M.S. Badawi, S.I. Jovanovic, A.A. Thabet, A.M. El-Khatib, A.D. Dlabac, B.A. Salem, et al., Calibration of 4π NaI(Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software, AIP Adv. 7 (2017), 035005, https://doi.org/10.1063/1.4978214.   DOI
14 A. Hamzawy, D.N. Grozdanov, M.S. Badawi, F.A. Aliyev, A.A. Thabet, M.I. Abbas, et al., New numerical simulation method to calibrate the regular hexagonal NaI(Tl) detector with radioactive point sources situated non-axial, Rev. Sci. Instrum. 87 (2016) 115105, https://doi.org/10.1063/1.4966990.   DOI
15 C.-Y. Yi, S.-H. Hah, Monte Carlo calculation of response functions to gammaray point sources for a spherical NaI(Tl) detector, Appl. Radiat. Isot. 70 (2012) 2133-2136, https://doi.org/10.1016/j.apradiso.2012.02.081.   DOI
16 A. Thabet, A. Dlabac, S. Jovanovic, M. Badawi, N. Mihaljevic, A. El-Khatib, et al., Experimental verification of gamma-efficiency calculations for scintillation detectors in ANGLE 4 software, Nucl. Technol. Radiat. Protect. 30 (2015) 35-46, https://doi.org/10.2298/ntrp1501035t.   DOI
17 S. Noureldine, M. Badawi, M. Abbas, A hybrid analytical-numerical method for efficiency calculations of spherical scintillation NaI(Tl) detectors and arbitrarily located point sources, Nucl. Technol. Radiat. Protect. 32 (2017) 140-147, https://doi.org/10.2298/ntrp1702140n.   DOI
18 H.M. Al-Arbawy, Study the effect of the shields movement and its thickness in detection efficiency by using scintillation detector NaI(Tl), Adv. Phys. Theor. Appl. 31 (2014) 53-57.
19 A. Hamzawy, New analytical approach to calculate the detector efficiencies of NaI(Tl) using coaxial and off-axis rectangular and parallelepiped sources, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 768 (2014) 164-169, https://doi.org/10.1016/j.nima.2014.09.013.   DOI
20 M.-C. Lepy, T. Altzitzoglou, M.J. Anagnostakis, D. Arnold, M. Capogni, A. Ceccatelli, et al., Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry, Appl. Radiat. Isot. 68 (2010) 1407-1412, https://doi.org/10.1016/j.apradiso.2010.01.012.   DOI
21 G. Giubrone, J. Ortiz, S. Gallardo, S. Martorell, M.C. Bas, Calculation of coincidence summing correction factors for an HPGe detector using GEANT4, J. Environ. Radioact. 158-159 (2016) 114-118, https://doi.org/10.1016/j.jenvrad.2016.04.008.   DOI
22 S.S. Nafee, M.S. Badawi, A.M. Abdel-Moneim, S.A. Mahmoud, Calibration of the 4π γ-ray spectrometer using a new numerical simulation approach, Appl. Radiat. Isot. 68 (2010) 1746-1753, https://doi.org/10.1016/j.apradiso.2010.02.013.   DOI
23 S. Byun, W. Prestwich, K. Chin, F. Mcneill, D. Chettle, Efficiency calibration and coincidence summing correction for a 4π NaI(Tl) detector array, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 535 (2004) 674-685, https://doi.org/10.1016/s0168-9002(04)01469-x.   DOI
24 A.M. El-Khatib, M.S. Badawi, M.A. Elzaher, A.A. Thabet, A study of the validity of the efficiency transfer method to calculate the peak efficiency using γ-ray detectors at extremely large distances, J. Theoret. Appl. Phys. 8 (2014), https://doi.org/10.1007/s40094-014-0120-1.   DOI
25 A.M. El-Khatib, B.A. Salem, M.S. Badawi, M.M. Gouda, A.A. Thabet, M.I. Abbas, Full-Energy peak efficiency of an NaI(Tl) detector with coincidence summing correction showing the effect of the source-to-detector distance, Chin. J. Phys. 55 (2017) 478-489, https://doi.org/10.1016/j.cjph.2016.11.013.   DOI