• 제목/요약/키워드: gamma-ray dose rate

검색결과 168건 처리시간 0.025초

Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정 (Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode)

  • 정만영;김덕진
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF

Assessment of the terrestrial gamma radiation dose in Korea

  • Choi, Seok-Won;Yun, Ju-Yong;Kim, Chang-Kyu;Rho, Byung-Hwan;Lee, Jong-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제30권4호
    • /
    • pp.161-165
    • /
    • 2005
  • The gamma-ray dose rates in air at 233 locations in Korea have been determined. The contribution to the gamma-ray dose rates in air due to the presence of $^{232}Th-series,\;^{238}U-series\;and\;^{40}K$ is as follows: 47.3% $(36\;nGyh^{-1})\;^{232}Th-series$ 14.5% $(11\;nGyh^{-1})\;^{238}U-series$ and 38.2% $(29\;nGyh^{-1})\;^{40}K$. The mean gamma-ray dose rate theoretically derived from $^{232}Th-series,\;^{238}U-series\;and\;^{40}K\;was\;76{\pm}17\;nGyh^{-1}$. This corresponds to an annual effective dose of $410\;{\mu}Sv$ and an annual collective dose of 18900 person-Sv for all provinces under study. The results have been compared with other global radiation dose.

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

고 선량율 감마선 조사에 따른 렌즈의 열화 (A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation)

  • 조재완;이준구;허섭;구인수;홍석붕
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

고선량율 감마선 환경하에서의 카메라 관측성능 (Monitoring Performance of Camera under the High Dose-rate Gamma Ray Environment)

  • 조재완;정경민
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1172-1178
    • /
    • 2012
  • In this paper, the gamma ray irradiation test results of the CCD cameras are described. From the low dose-rate (2.11 Gy/h) to the high dose-rate (150 Gy/h) level, which is the same level when the hydrogen explosion was occurred in the 1~3 reactor unit of the Fukushima nuclear power plant, the monitoring performance of the cameras owing to the speckles are evaluated. The numbers of speckles, generated by gamma ray irradiation, in the image of cameras are calculated by image processing technique. And the legibility of the sensor indicator (dosimeter) owing to the numbers of the speckles is presented.

적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석 (Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image)

  • 조재완;홍석붕;구인수
    • 제어로봇시스템학회논문지
    • /
    • 제17권12호
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.

고 선량 감마선 조사에 따른 고휘도 LED의 가시광 무선 데이터 전송 (VLC Wireless Data Transmission of High Luminance LED Irradiated by the High Dose-Rate Gamma-Ray)

  • 조재완;최영수;홍석붕
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.996-1000
    • /
    • 2010
  • In order to apply VLC (visible light communication) in harsh environment of nuclear power plant in-containment building, the high luminance LEDs, which are key components of the VLC system, have been gamma irradiated at the dose rate of 4 kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced coloration effect in the high luminance LED bulb made of acryl or plastic material was observed. In the VLC wireless data transmission experiment using the high luminance LEDs irradiated by high dose rate gamma-ray, the radiation induced coloration effect of the high luminance LED bulb extended the communication distance compared to non-irradiated LEDs.

저선량 감마선 조사가 파종자의 발아에 비치는 영향 (The Acceleration of Germination in Welsh Onion Seed Irradiated with the Low Dose ${\gamma}-ray$ Radiation)

  • 이은경;김재성;이영근;이영복
    • 한국환경농학회지
    • /
    • 제17권4호
    • /
    • pp.346-351
    • /
    • 1998
  • 방사선 hormesis 효과를 알아보기 위하여 저선량의 방사선을 조사한 후 파종자의 발아양상을 비교하였다. 흥농종묘(주)에서 분양받은 1997년산 '온천'파종자는 대조구에 비해 저선량의 방사선이 조사구에서 약 10%정도 증가된 발아율 양상을 보였으며, 기내배양에서도 마찬가지로 8 Gy 조사구에서 약 10%정도 증가되는 것을 알 수 있었다. 중앙종묘(주)로부터 분양받은 1992년산 '석창외대'파종자의 경우 대조구에서는 약 42.7%의 발아율을 보인 반면 4Gy가 조사된 처리구에서는 약 78.0%까지 발아율이 증가하는 것으로 나타났다. 전반적으로 최적의 비옥토양에서 보다는 비경작지에서 방사선 유익효과가 증가되는 양상을 보였다. 흡습지에서의 발아율 양상은 대조구의 발아율이 22%로 매우 저조한 반면, 1 Gy 조사구에서는 38%까지 발아율이 증가되어 약 16%정도 증가율을 보였다. Paper towel을 이용한 발아율 실험에서 역시 1Gy 조사구에서 발아율이 증가되는 경향을 보였는데 역시 대조구에 비해 1 Gy 조사구에서 약 10% 정도 증가하는 양상을 보였다. 발아율이 증가되었던 저선량 방사선 조사구의 전기전도도를 조사해 본 결과 대조구에 비해 낮아지는 경향을 보였다. 결론적으로 1Gy에서 10Gy정도의 저선량 방사선 수준에서 파종자의 발아율 증가효과가 나타나는 것으로 사료된다.

  • PDF

중성자(中性子) 및 감마선(線)에 대한 선량율(線量率) 환산인자(換算因子) 계산(計算) (Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors)

  • 권석근;이수용;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제6권1호
    • /
    • pp.8-24
    • /
    • 1981
  • This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute(ANSI) N666. These data are used to calculated the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from $2.5{\times}10^{-8}$ to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoetiergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be a useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions.

  • PDF

기내$\gamma$-선 처리에 의한 감(Diospyros kaki Thunb.) 돌연변이 유기 (Induction of Mutants by Irradiation of $\gamma$-Ray on In vitro Shoots of Persimmon)

  • 고갑천
    • 식물조직배양학회지
    • /
    • 제27권2호
    • /
    • pp.143-148
    • /
    • 2000
  • 감 돌연변이 획득을 위해 기내배양 신초에 ${\gamma}$-선을 조사하여 변이유기를 위한 적정 선량, ${\gamma}$-선 조사 식물체의 기내 발근 및 생육 특성을 조사한 결과는 다음과 같다. 감 돌연변이 유기를 위한 적정한 조사 선량 (LD$_{50}$)은 서촌조생 품종에서 1 krad와 2 krad사이이었고, 일목계차랑 품종은 1 krad이었다. ${\gamma}$-선을 조사한 신초를 1차,2차, 3차에 걸쳐 계대배양하는 각 기간의 기내 생육상태를 보면 ${\gamma}$-선량이 증가할수록 기내에서 생장한 신초의 길이가 감소하였으며, 신초의 정아가 가장 장애를 많이 받았다. 서촌조생 품종에서 신초의 37.5~58.3% 정도가 발근되었고 발근율은 2 krad 처리에서는 가장 낮았다. ${\gamma}$-선 조사선량이 높아지면 발근율과 뿌리의 발생수가 줄어들었다. 순화한 뒤 6주 동안 생장상에서 생육한 ${\gamma}$-선 조사 개체는 무처리 개체의 묘고가 6.0 cm인데 비해 2krad 처리개체는 평균 묘고는 2.6 cm에 불과하였다. 또한 발생한 가지의 수도 무처리에서는 1.0개인데 비해 2krad에서는 1.8 개로 많았다. 온실 생육시에서 ${\gamma}$-선 처리선량이 높았던 개체는 처리되지 않았거나 낮았던 개체에 비해 묘고가 작고 분지수가 많았으며, 생육상태도 부진하여 생육 중에 33%정도만 생존하고 나머지는 고사하였다.다.

  • PDF