• Title/Summary/Keyword: gamma ray dose

Search Result 481, Processing Time 0.026 seconds

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

Isolation of Gamma-Induced Rice Mutants with Increased Tolerance to Salt by Anther Culture

  • Lee, In-Sok;Kim, Dong-Sub;Hyun, Do-Yoon;Lee, Sang-Jae;Song, Hi-Sup;Lim, Yong-Pyo;Lee, Young-Il
    • Journal of Plant Biotechnology
    • /
    • v.5 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Doubled haploids have long been recognized as a valuable tool in plant breeding since it not only offers the quickest method of advancing heterozygous breeding lines to homozygosity, but also increased the selection efficiency over conventional procedures due to better discrimination between genotypes within any one generation. Salt tolerant mutants were obtained in rice the variety, 'Hawsungbyeo', through in vitro mutagenesis of in vitro cultured anther-derived calli. Various doses (30, 50, 70 and 90 Gy) of gamma ray were applied to investigate the effect of radiation on callus formation on medium containing 1% NaCl, green plant regeneration, frequency of selected doubled haploid mutants and of the salt tolerant screen. It was demonstrated that the dose of 30 and 50 Gy gamma rays had significant effects on callus formation, regeneration and selection of salt tolerance. No tolerant lines were obtained from non-mutagenized cultures. From gamma ray irradiated cultures, five tolerant lines ($M_2$generation) at germination stage and 13 tolerant lines ($M_3$genoration) at seedling stage were obtained. The frequency of salt tolerant mutants indicates that anther culture applied in connection with gamma rays is an effective way to improve salt tolerance.

A Study of the Thermoluminescent Properties of Korean Natural Quartz for Possible Use in Gamma-ray Dosimetry

  • Lee, Hee-Yong;Kim, Hi-Gyu;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.229-239
    • /
    • 1970
  • Various thermoluminescent properties of Korean natural quartz for possible use in ${\gamma}$-ray dosimetry has been studied. If the heating is exactly linear, ${\gamma}$-irradiated radiation sensitive (type 1) $\alpha$-quartz can yield a glow curve of single peak, hence glow peak height could be taken as a ${\gamma}$-dose for its dosimetry. Quartz crystal dosimeter exhibited the linearity of thermoluminescent intensity in the range from about 2$\times$10$^{3}$R to 2$\times$10$^{6}$ R, and also had an advantage of low fading because of the high peak temperature (300$\pm$4$0^{\circ}C$). The pulverized quartz sample having the grain size of 0.3<ø<0.9mm showed the linearity of T. L. intensity in the range from 50R to 2$\times$10$^3$R. Therapeutic application of the pulverized sample on the correct measurement of the absorbed dose in a body region of a cancer patient seems to be successful.

  • PDF

The Dielectric Properties due to the Temperature and Applied Voltage of Oriented Polypropylene Film Irradiated by $^{60}/Co-${\gamma}$$ ($^{60}/Co-${\gamma}$$선으로 조사된 이축연신 폴리프로필렌 필림의 온도 및 전압에 따른 유전특성)

  • 홍진웅;이수원;김왕곤
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 1994
  • In this paper, It is studied that the variation of the dielectric absorption of the specimen according to the change with $^{60}$ Co-${\gamma}$ ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiated oriented polypropylene film, we have observed dielectric properties within the temporature range of 30~130 ($^{\circ}C$) and voltage range of 100~250 (V). As for the dependency of temperature by tan $\delta$, the $\alpha$ peak which appears at high temperature increases accordingly to the increment of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The $\beta$ peak which appears the orientation by dipoles and molecular motions in the amorphous region at low temperature. For the dependency of voltage by tan $\delta$ at low temperature, the peak of the tan $\delta$ shifts accordingly to the increment of irradiation dose towards the high temperature region.

  • PDF

High Dose $^{60}Co\;{\gamma}$-Ray Irradiation of W/GaN Schottky Diodes

  • Kim, Jihyun;Ren, F.;Schoenfeld, D.;Pearton, S.J.;Baca, A.G.;Briggs, R.D.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.124-127
    • /
    • 2004
  • W/n-GaN Schottky diodes were irradiated with $^{60}Co\;{\gamma}-rays$ to doses up to 315Mrad. The barrier height obtained from current-voltage (I-V) measurements showed minimal change from its estimated initial value of ${\sim}0.4eV$ over this dose range, though both forward and reverse I-V characteristics show evidence of defect center introduction at doses as low as 150 Mrad. Post irradiation annealing at $500^{\circ}C$ increased the reverse leakage current, suggesting migration and complexing of defects. The W/GaN interface is stable to high dose of ${\gamma}-rays$, but Au/Ti overlayers employed for reducing contact sheet resistance suffer from adhesion problems at the highest doses.

Natural Beryl as a Thermoluminescent Dosimeter

  • Moon, P.S.
    • Nuclear Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.151-154
    • /
    • 1974
  • The possibility of using natural beryl thermoluminesence for gamma-ray dose measurement was investigated through the analysis of glow curves obtained with Co-60 gamma-ray irrediation. The natural beryl powder of 80-200 mesh has a good gamma-ray thermoluminescent response and stability at room temperature. The thermoluminescent response is linear from 10mR to 10$^3$R and can be measured up to 10$^{6}$ R.

  • PDF

Relationship between Crosslinking Processes and Mechanical Properties of UHMWPE for Artificial Joint (인공관절용 초고분자량폴리에틸렌의 가교결합 공정변수와 기계적 특성과의 상관관계)

  • Kim, H.M.;Kim, S.K.;Lee, J.D.;Yun, I.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1570-1574
    • /
    • 2008
  • Various mechanical test were conducted on conventional and crosslinked ultra-high molecular weight polyethylene(UHMWPE) all prepared from the same lot of medical grade GUR 1050 for artificial joint. The conventional materials were not irradiated and treated by heating. The cosslinked materials were irradiated with $25kGy{\sim}200kGy$ by gamma-ray andthen annealed or remelted. Gamma-ray irradiation and heat treatment process were found to significantly impact the crystallinity, and hence the mechanical behavior, of the highly crosslinked UHMWPE. The radiation dose and heating conditions were key predictors of the uniaxial yielding, plastic flow, and failure properties of conventional and highly crosslinked UHMWPE. The correlation model from experiments would be the basic information to enhance the were resistance of artificial joint liner.

  • PDF

Effect of Oxidants on Decomposition of Acetaminophen by Gamma Irradiation (Acetaminophen의 감마선 분해에 대한 산화제 영향)

  • Lee, Myunjoo;Ahn, Young Deok;Lee, Kyoung-hwon;Lee, O Mi;Kim, Tae-Hun;Jung, In-ha;Yu, Seungho
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.359-364
    • /
    • 2011
  • This study was aimed to investigate the effect of oxidants on biodegradability and decomposition of acetaminophen (ACT) by gamma ray. Three kinds of chemical, potassium persulfate, hydrogen peroxide and ferrous sulfate were selected as an oxidant. The absorbed dose was ranged from 0.2 to 10 kGy and the concentration of oxidants was from 0.1 to 10 mM and the initial concentration of acetaminophen was $30mg\;l^{-1}$ in this study. The concentration of ACT was gradually decreased corresponding to the increase of the absorbed dose. However, mineralization of ACT was not occurred by the increased of the absorbed dose. When the 10 mM of oxidants applied to the ACT aqueous solution, the concentration of ACT was rapidly decreased according to absorbed dose and the mineralization was observed in potassium persulfate. Biodegradability of ACT with potassium persulfate was higher than that of ACT without potassium persulfate in lower absorbed dose and decreased according to higher absorbed dose.

Adaptive Response Induced by Low Dose Ionizing Radiation in Human Lymphocytes (인체 말초 혈액 림프구에서 저선량 방사선 조사에 의해 유도되는 적응 반응)

  • Kim, Jeong-Hee;Lee, Kyung-Jong;Cho, Chul-Koo;Yoo, Seong-Yul;Kim, Tae-Hwan;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.97-102
    • /
    • 1995
  • Adaptive response induced by low dose ${\gamma}-ray$ irradiation in human peripheral lymphocytes was examimed. Human lymphocytes were exposured to low dose of ${\gamma}-ray$ (priming dose, 0.01Gy) followed by high dose (challenging dose, 1.5Gy) after various time intervals (4, 7, 20 hours). Frequencies of micronuclei were enumerated in both primed and unprimed groups. Maximum reduction in frequency of micronuclei was observed when challenging dose irradiation was followed by priming dose after 4hr incubation period. When challenging doses were irradiated 7 or 20hr after priming dose, frequencies of micronuclei were reduced slighty. However, these reduction were not statistically significant. In this study, human peripheral lymphocytes were irradiated at Go phase and they showed adaptive response induced by low dose radiation. Since micronucleus assay is relatively simpler and faster than other methods, it may be a good tool for evaluating radiation-induced adaptive responses.

  • PDF

SIMULATION OF SHIELDING EFFECTS ON THE TOTAL DOSE OBSERVED IN TDE OF KITSAT-1 (KITSAT-1 TDE의 차폐 효과에 의한 총 축적 방사능양 변화에 대한 연구)

  • 김성준;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.71-80
    • /
    • 2001
  • The threshold voltage shift observed in TDE (Total Dose Experiment) on board the KITAT-1 is converted into dose (rad($SiO_2$)) using the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute). Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  • PDF