• 제목/요약/키워드: fundamental frequency component

검색결과 113건 처리시간 0.022초

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

헬리컬 기본교란과 축대칭 분수조화교란을 이용한 원형제트에서의 보텍스 병합 및 제트확산 (Vortex Pairing and Jet-Spreading in an Axisymmetric Jet under Helical Fundamental and Axisymmetric Subharmonic Forcing)

  • 조성권;유정열;최해천
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1610-1624
    • /
    • 1998
  • An axisymmetric jet is forced with two helical fundamental waves of identical frequency spinning in opposite directions and an additional axisymmetric sub harmonic wave. The subharmonic component rapidly grows downstream from subharmonic resonance with the fundamental, significantly depending on the initial phase difference. The variations of the subharmonic amplitude with the initial phase difference show cusp-like shapes. The amplification of the sub harmonic results in 'vortex pairing of helical modes'. Furthermore, azimuthal variation of the amplification induces an asymmetric jet cross-section. When the initial subharmonics is imposed with an initial phase difference close to a critical value, the jet-cross section evolves into a three-lobed shape. One lobe is generated by the enhanced vortex pairing and the other two lobes are generated by the delayed vortex pairing. Thus, it is confirmed that the initial phase difference between the fundamental and the subharmonic plays an important role in controlling the jet cross-section.

확장된 3차원 전류 좌표계에 의한 능동전력필터의 보상성능 평가 (Compensating Performance Evaluation of Active Power Filters Using the Expanded 3-D Current Coordinates)

  • 김정근;임영철;정영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.292-295
    • /
    • 2003
  • Conventional methods in time / frequency domain for evaluating the compensation performance of active power filters are not provided easy solutions. So, the authors have previously proposed 3-D current coordinates which is composed into active component, fundamental reactive component and distorted component of nonlinear loads current. This method has excellent performance, but can not evaluate the characteristics of nonlinear load current whether it is inductive or capacitive. Therefore, To overcome problems mentioned previously, this paper deals with the simple Average power theory and the expanded 3-D current coordinates for evaluating the compensation performance of active power filters. To confirm the validity, active power filters simulator is developed using C-language. From the simulation, results are discuss their utility.

  • PDF

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • 칸 레이안;최우진
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.231-239
    • /
    • 2018
  • The phase-locked loop (PLL) is widely used in grid-tie inverter applications to achieve a synchronization between the inverter and the grid. However, its performance deteriorates when the grid voltage is not purely sinusoidal due to the harmonics and the frequency deviation. Therefore, a high-performance PLL must be designed for single-phase inverter applications to guarantee the quality of the inverter output. This paper proposes a simple method that can improve the performance of the PLL for the single-phase inverter under a non-sinusoidal grid voltage condition. The proposed PLL can accurately estimate the fundamental frequency and theta component of the grid voltage even in the presence of harmonic components. In addition, its transient response is fast enough to track a grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2017
  • The Phase-Locked Loop (PLL) is widely used in grid-tie inverter applications to achieve the synchronization between the inverter and the grid. However, its performance is deteriorated when the grid voltage is not pure sinusoidal due to the harmonics and the frequency deviation. Therefore it is important to design a high performance phase-locked loop (PLL) for the single phase inverter applications to guarantee the quality of the inverter output. In this paper a simple method to improve the performance of the PLL for the single phase inverter is proposed. The proposed PLL is able to accurately estimate the fundamental frequency component of the grid voltage even in the presence of harmonic components. In additional its transient response is fast enough to track a change in grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

  • PDF

A DFT Based Filtering Technique to Eliminate Decaying dc and Harmonics for Power System Phasor Estimation

  • Oh Yong- Taek;Balamourougan V.;Sidhu T.S.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.138-143
    • /
    • 2005
  • During faults, the voltage and current signals available to the relay are affected by the decaying dc component and harmonics. In order to make appropriate and accurate decisions, most of the relaying algorithms require the fundamental frequency phasor information that is immune to decaying dc effect and harmonics. The conventional Fourier ph as or estimation algorithm is affected by the presence of decaying-exponential transients in the fault signal. This paper presents a modified Fourier algorithm, which effectively eliminates the decaying dc component and the harmonics present in the fault signal. The decaying dc parameters are estimated by means of an out-of-band filtering technique. The decaying dc offset and harmonics are removed by means of a simple computational procedure that involves the design of two sets of Orthogonal digital OFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying dc component. It was also compared with the conventional mimic plus the full cycle OFT algorithm. The results indicate that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus OFT algorithms over a wide range of decay rates. In all cases, the convergence to the desired value was achieved within one cycle of the power system frequency.

단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구 (A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters)

  • 황선환;황영기;권순걸
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

가변속 유도 전동기를 구동하기 위한 PWM인버터의 새로운 변조 방식 (A Novel Modulation Techniques for Driving a Variable-Speed Induction Motor)

  • 윤병도;전희종;김국진;정율기;손진근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.600-604
    • /
    • 1991
  • In this paper, an advanced PWM modulation strategy for driving a variable-speed induction motor is introduced. According to this method, the technique of efficiently eliminating harmonics component is achived. A switching pattern was computed making use of the near-proportionality of voltage and frequency in AC machines operating with constant flux. At low magnitudes and low frequencies of the foundamental, many more harmonics are eliminated than at high magnitudes and frequencies. In order to keep the inverter switching frequency constant over the output frequency range, chopping times diminishes as the frequency of the fundamental increases.

  • PDF

Design of a sub-harmonic dual-gate FET mixer for IMT-2000 base-station

  • Kim, Jeongpyo;Park, Jaehoon
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1046-1049
    • /
    • 2002
  • In this paper, a sub-harmonic dual-gate FET mixer for IMT-2000 base-station was designed by using single-gate FET cascode structure and driven by the second order harmonic component of LO signal. The dual-gate FET mixer has the characteristic of high conversion gain and good isolation between ports. Sub-harmonic mixing is frequently used to extend RF bandwidth for fixed LO frequency or to make LO frequency lower. Furthermore, the LO-to-RF isolation characteristic of a sub-harmonic mixer is better than that of a fundamental mixer because the frequency separation between the RE and LO frequency is large. As RF power is -30dBm and LO power is 0dBm, the designed mixer shows the -47.17dBm LO-to-RF leakage power level, 10dB conversion gain, -0.5dBm OIP3, -10.5dBm IIP3 and -1dBm 1dB gain compression point.

  • PDF

ESS의 전자 잡음 주파수 분석 및 제거 (Frequency Analysis and Reduction of Electronic Noise in ESS)

  • 안봉만;한병성;한운기;이영관;안현진
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.568-575
    • /
    • 2022
  • This paper is a study on frequency analysis and electronic noise reduction of energy storage system (ESS). We acquired 4 necessary data for about 2 minutes and 4 seconds using a sampling frequency of 10,000 Hz in ESS. Fast Fourier transform (FFT) was used for electronic noise analysis from the acquired data. As a result, it was confirmed that DC component, fundamental wave, second and higher harmonic component exist. For the attenuation of harmonics, low-pass filter (LPF) was applied. We confirmed that an attenuation of approximately 59.3% appears from the second harmonic. The presence of many harmonic components in the data of the ESS was expected to occur due to the insufficiency of optimization among the modules inside the ESS. Therefore, we propose that a national certification system for ESS should be introduced to settle down the issue properly.