• 제목/요약/키워드: full-size structural performance test

검색결과 16건 처리시간 0.027초

격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가 (Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members)

  • 노명현;안동욱;주형중
    • 복합신소재구조학회 논문집
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

대형 망원경용 FSM(Fast Steering Secondary Mirror)을 위한 팁틸트 액츄에이터의 성능평가 (Performance Evaluation of the Tip-tilt Actuator in Fast Steering Secondary Mirror for Large Telescope)

  • 김호상;이동찬;이경돈;김영수
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.403-409
    • /
    • 2014
  • For ground-based telescope application, the performance assessment of tip-tilt actuator is important because the optical quality of telescope depends upon the windshake compensation ability of the fast steering secondary mirror. But it is difficult to measure the performance characteristics of the actuators due to the large size mirror and test facilities including the vacuum support and structural frame. In this paper, the full-scale tip-tilt test bed for the large size secondary mirror with diameter of 1m is built and the several tests are performed including the range, resolution and frequency response function. From the measurement results, it is shown that the tip-tilt actuator can successfully compensate the windshake with frequency of maximum 12 Hz and be a candidate for the Giant Magellan Telescope.

강재의 단면형상에 따른 내화피복두께 산정 연구 (Study on the Determination of Fire Protection Thickness based on Section Factor)

  • 정청운;지남용;권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

미국과 유럽의 풍력터빈 풍동실험 (Wind tunnel test of wind turbine in United States and Europe)

  • 장병희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.42-46
    • /
    • 2005
  • In spite of fast growing of prediction codes, there is still not negligible uncertainty in their results. This uncertainty affects on the turbine structural design and power production prediction. With the growing size of wind turbine, reducing this uncertainty is becoming one of critical issues for high performance and efficient wind turbine design. In this respect, there are international efforts to evaluate and tune prediction codes of wind turbine. As the reference data for this purpose, field test data is not appropriate because of its uncontrollable wind characteristics and its inherent uncertainty. Wind tunnel can provide controllable wind. For this reason, NREL has done the full scale test of the 10m turbine at NASA-Ames. With this reference data, a blind comparison has been done with participation of 18 organizations with 19 modeling tools. The results were not favorable. In Europe, a similar project is going on. Nine organizations from five countries are participating in the MEXICO project to do full scale wind tunnel tests and calculation with prediction codes. In this study. these two projects were reviewed in respect of wind tunnel test and its contribution. As a conclusion, it is suggested that scale model wind tunnel tests can be a complementary tool to calculation codes which were evaluated worse than expected.

  • PDF

보수성을 개선한 복합형 신축이음장치(HRS) 내구성 평가 (Durability Evaluation of Hybrid Expansion Joint System with Improved Replacement)

  • 이정우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.1-7
    • /
    • 2023
  • 기존 신축이음장치 교체 시간을 절감하고, 차선별 부분교체가 가능하도록 보수성을 개선한 신축이음장치 시스템(HRS)에 대하여 실물규모의 수직하중 피로시험과 윤하중 성능실험을 수행하여 내구성을 평가하였다. 수직하중 피로시험결과 레일형 신축이음장치의 최대응력은 170 Mpa이며, 이는 HRS 신축이음장치레일의 항복강도 355MPa의 약 47.8% 수준이다. 보수성을 개선한 HRS 신축이음장치의 수직하중 피로시험은 도로교설계기준에 따라 재하판의 크기와 하중을 설정하였고, 200만회 수직하중 피로시험과 윤하중 성능실험에 있어서 파괴거동을 나타내지 않았으며 그 내구성과 안전성을 확인하였다.

고강도 모르타르 충전식 철근이음의 구조성능에 관한 실험연구 (Structural Performance of High Strength Grout-Pilled Splice Sleeve System)

  • 김형기;안병익;남재현;박복만
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.516-524
    • /
    • 2001
  • 여러가지 철근이음 방법중에서 고강도 모르타르 충전식 철근이음은 철근위치의 오차를 쉽게 흡수하여 시공이 용이하고 또한 최근에 많이 사용되고 있는 대구경 철근에 대해서도 적용성이 양호하기 때문에 프리캐스트 공법의 철근이음 방법으로 매우 유효한 수단이 된다. 이에 본 연구에서는 모르타르 충전식 철근이음법의 적용범위를 보다 확장하기 위하여 슬리브에 매입되는 철근직경이 상이한 경우와 충전 모르타르 강도를 700kgf/$\textrm{cm}^2$대로 낮춘 경우의 모르타르 충전식 철근이음에 대한 단조 및 반복가력 구조성능 실험을 실시한 후에 기존 실험결과와의 비교 분석을 통하여 다음과 같은 결론을 얻었다. 충전 모르타르 압축강도가 증가할수록 전체적인 구조성능은 증가하는 경향을 나타내었고 충전 모르타르 압축강도가 700kgf/$\textrm{cm}^2$이상이고 철근정착길이가 6.5d 이상이면 A급(AIJ 철근이음 성능 판정기준) 이상의 구조성능을 보유하고 있는 것이 확인되었다. 또한 슬리브 양단에 매입되는 철근의 직경이 상이한 경우는 굵은 철근에 대응되는 슬리브를 사용해야 하고 매입되는 가는 철근은 굵은 철근보다 2단계까지 가는 것을 사용할 수 있다는 것이 확인되었다.

2층 RC 전단벽식 구조물의 내진성능에 대한 정적 실험 (Static Experiment for the Seismic Performance of a 2 Story RC Shear Wall System)

  • 이상호;오상훈;황원태;이경보;이한선
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.55-65
    • /
    • 2010
  • 본 실험 연구의 목적은 횡방향 정적가력을 통하여 2층 R.C 전단벽식 구조의 내진성능을 평가하는 것이다. 본 연구의 실험체는 대상 건물의 개구부를 가지는 T자형 벽체 1층과 2층의 일부분을 대상으로 실물크기의 3/5 크기정도로 축소하였고, 인방보의 유 무를 실험변수로한 2개의 실험체를 제작하여 횡방향의 정적가력 실험을 수행하였다. 인방보 유무에 따른 벽체의 구조적 성능 및 거동의 차이를 비교한 결과, 인방보가 있는 실험체가 인방보가 없는 실험체보다 최대내력과 연성능력 등의 내진성능이 우수한 것으로 판단되었다.

SRC기둥-H형단면과 U형단면으로 구성된 합성보 접합부의 반복가력실험 (Cyclic Loading Test on Connection of SRC Column-Composite Beam Consisting of H-Section and U-Section Members)

  • 김영주;배재훈;안태상;김진원;유홍식
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.263-275
    • /
    • 2014
  • 본 연구에서는 SRC 기둥-H형단면과 U형단면으로 구성된 합성보 접합부에 관해서 반복가력실험을 실시하였다. 합성보에 관한 핵심요소는 H형단면과 U형단면 간 용접접합부의 구조적 성능이다. 이 두 부재 접합부의 성능을 향상시키기 위해서는 수직스티프너와 사다리꼴 스티프너가 필요하다. 접합부의 반복적인 성능을 평가하기 위해서 5개의 실대형 실험체를 계획하였으며, 실험변수는 H형단면의 크기($H-500{\times}200{\times}10{\times}16$, $H-600{\times}200{\times}11{\times}17$), 스티프너와 상부근의 유무 및 용접접근공(WAH)의 유무 등이다. 실험결과, H-500 시리즈 및 H-600 시리즈 보가 있는 실험체의 회전각은 각각 4%와 3%로 나타났으며, 이는 특수모멘트골조와 중간모멘트골조에 요구되는 값이다. 실험결과는 스티프너와 상부근이 있는 실험체의 변형능력이 그렇지 않은 실험체에 비해서 우수한 결과를 보였다. 끝으로, 실험체의 에너지소산능력과 변형도 분포를 요약하였다.

중력하중을 받는 SRC기둥-합성보 접합부 실험 (Test of SRC Column-to-Composite Beam Connection under Gravity Loading)

  • 김영주;배재훈;안태상;장성훈
    • 한국강구조학회 논문집
    • /
    • 제26권5호
    • /
    • pp.441-452
    • /
    • 2014
  • 본 논문에서는 중력하중을 받는 SRC기둥과 합성보 접합부의 정적실험을 수행하였다. 합성보는 H형단면과 U형단면으로 구성되어 있다. 모두 5개의 실대형 실험체를 설계하여 실험변수, 즉, H형단면 크기, 스터드커넥터의 유무, 스티프너와 상부근의 유무 등이 접합부의 거동에 미치는 영향을 조사하였다. 또한 H형단면과 U형단면의 용접접합부의 구조성능을 초기강성, 내력 및 변형능력을 중심으로 기술하였다.