Abstract

Durability was evaluated by performing a full-scale vertical load fatigue test and a wheel load performance test on the HRS, which reduces the replacement time of the existing expansion joint and improves serviceability to allow partial replacement by lane. As a result of the vertical load fatigue test, the maximum stress of the rail-type expansion joint is 170 MPa, which is about 47.8% of the yield strength of the HRS expansion joint rail 355 MPa. The vertical load fatigue test of the HRS expansion joint with improved serviceability set the size and load of the load plate according to the road bridge design standards, did not show any fracture behavior in the vertical load fatigue test and the wheel load performance test 2 million times, and its durability and safety were verified.

기존 신축이음장치 교체 시간을 절감하고, 차선별 부분교체가 가능하도록 보수성을 개선한 신축이음장치 시스템(HRS)에 대하여 실물규모의 수직하중 피로시험과 윤하중 성능실험을 수행하여 내구성을 평가하였다. 수직하중 피로시험결과 레일형 신축이음장치의 최대응력은 170 Mpa이며, 이는 HRS 신축이음장치레일의 항복강도 355MPa의 약 47.8% 수준이다. 보수성을 개선한 HRS 신축이음장치의 수직하중 피로시험은 도로교설계기준에 따라 재하판의 크기와 하중을 설정하였고, 200만회 수직하중 피로시험과 윤하중 성능실험에 있어서 파괴거동을 나타내지 않았으며 그 내구성과 안전성을 확인하였다.

Keywords

Acknowledgement

본 연구는 국토교통부 국토교통기술촉진연구사업의 연구비지원(18CTAP-B132914-02) 및 대봉비엠텍(주)의 시험체 제공에 의해 수행되었으며 이에 감사드립니다.

References

  1. AASHTO. (2014), AASHTO LRFD Bridge design specifications.
  2. Dexter, R. J., Connor, R. J, and Kaczinski, M. R.(1997), Fatigue design of modular bridge expansion joints, NCHRP Report 402, National Academy press.
  3. Korea road Association. (2015), Korean Highway Bridge Design Code(Limit State Design), Sejong South Korea.
  4. Korea Standards Association. (2001), KS F 4425, Testing method for bridge expansion joint, Korean Standards Association.
  5. Yoo, S. W., (2018), An Experiment of Structural Performance of Expansion Joint with Rotation Finger, Journal of the Korea Institute for Structural Maintenance and Inspection, 22(6), 170-175.
  6. Na, J. S., Lee, T., Han, E. S., Sung, W. K., and Lee, J. S. (2017), Fatigue Durability Evaluation of Refraction Expansion Joints, Journal of the Korea Institute for Structural Maintenance and Inspection, 21(6),10-15.
  7. Kim, K. Y., Kim, Y. J., Ahn, D. G., and Kim, C. H. (2009), Evaluation of Fatigue Endurance on Expansion Joint Manufactured Fe-Mn Damping Alloy, Journal of Korean Society Civil Engineers, KSCE, 29(4D), 483-489.