• Title/Summary/Keyword: front electrodes

Search Result 68, Processing Time 0.034 seconds

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

Thin Metal Electrodes for Semitransparent Organic Photovoltaics

  • Lee, Kyu-Sung;Kim, Inho;Yeon, Chang Bong;Lim, Jung Wook;Yun, Sun Jin;Jabbour, Ghassan E.
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.587-593
    • /
    • 2013
  • We demonstrate semitransparent organic photovoltaics (OPVs) based on thin metal electrodes and polymer photoactive layers consisting of poly(3-hexylthiophene) and [6,6]-phenyl $C_{61}$ butyric acid methyl ester. The power conversion efficiency of a semitransparent OPV device comprising a 15-nm silver (Ag) rear electrode is 1.98% under AM 1.5-G illumination through the indium-tin-oxide side of the front anode at 100 $mW/cm^2$ with 15.6% average transmittance of the entire cell in the visible wavelength range. As its thickness increases, a thin Ag electrode mainly influences the enhancement of the short circuit current density and fill factor. Its relatively low absorption intensity makes a Ag thin film a viable option for semitransparent electrodes compatible with organic layers.

Effect of Aluminum Fence-type electrode Design on Characteristics of AC-PDP

  • Lee, Seog-Young;Lee, Dong-Heon;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.408-411
    • /
    • 2008
  • In an attempt to enhance luminance efficiency and to reduce discharge delays of test panels with aluminum fence-electrodes, various designs of the electrodes were prepared by chemically etching the aluminum foils bonded to soda-lime glass substrate via anodic bonding process. The effects of fence design on luminance and discharge characteristics were investigated and compared with conventional ac-PDPs. These results showed a possibility of using fence-type aluminum electrode at front plates of ac-PDDs without sacrificing its performance.

  • PDF

New PDP cell structure for high luminous efficacy with low voltage driving

  • Jung, Hae-Yoon;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.480-484
    • /
    • 2006
  • We propose a new PDP cell structure named DIDE (Dual Ignition Discharge Electrodes) structure with a long electrode gap to realize a high luminous efficacy. Suggested DIDE structure basically has a long electrode gap $(200{\mu}m{\sim}400{\mu}m)$, nevertheless, because of auxiliary electrodes formed on the front panel, can be driven at relatively low voltage. The discharge characteristic of DIDE structure was much different from that of conventional structure, which was analyzed by IR emission images using IICCD (Image Intensified Charge Coupled Device). The study can explain some particular characteristics of DIDE structure. As a result, the long electrode gap and low voltage effect can be expected in DIDE structure, and a very high luminous efficacy of 7.5 lm/W has been achieved in monochrome green test panel adopting the new cell structure with Ne-Xe (12%) mixture at 400 torr.

  • PDF

Discharge Characteristics of AC PDP Cell as a parameter of PDP Cell structure (표면방전형 PDP Cell의 상,하판 구조에 따른 방전특성)

  • Park, Young-Chan;Chi, Sung-Won;Kim, Gyu-Seup;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1749-1751
    • /
    • 1997
  • AC PDP with surface micro discharge has a structure that all discharge electrodes are arranged on the front glass panel, and the rear glass panel merely serves as a cover glass to form the micro discharge space. The relationships between the dischage voltage and the structure among such as electrode width, distance between electrodes, discharge space gap, and dielectric layer width are investigated.

  • PDF

Bendable ac-PDP using Fence-Structured Electrodes on Polyethylene Terephthalate Substrate

  • Choi, Won-Yeol;Hong, Cho-Rong;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.593-596
    • /
    • 2007
  • A possibility of manufacturing bendable ac-PDP using aluminum electrode with anodic aluminum oxide dielectric material system on PET film substrate was explored. For this structure, PET film with fence-structured aluminum electrodes was used for front plate and PET film with barrier ribs of UV curable resin for the rear plate. The results demonstrate that it is feasible to manufacture the bendable ac-PDPs using those material system and are expected to expand the applications of plasma display panels.

  • PDF

New electron source and electron collection source for the internal electron circuit in FL tubes

  • Ozawa, Lyuji;Tian, Yakui;Kato, Masatoshi
    • Journal of Information Display
    • /
    • v.12 no.2
    • /
    • pp.69-75
    • /
    • 2011
  • A new electron source and an electron collection source were found for the closure of the internal electron circuit inside fluorescent lamp (FL) tubes. The sources are formed in front of the polarized electric-insulator particles on the metal electrodes at both ends of the FL tube. The appearance and disappearance of both sources are controlled by the electric voltages applied to the metal electrodes. The electrons and $Ar^+$ for the sources are generated by the ionization of the Ar atoms, and they return to the Ar atoms at the electron collection source. Thus, the Ar atoms are preserved in the FL tubes, ensuring a long operation life for such tubes.

Effect of Moisture on Cu(In,Ga)Se2 Solar Cell with (Ga,Al) Co-doped ZnO as Window Layer ((Ga,Al)이 도핑된 ZnO를 투명전극으로 가진 Cu(In,Ga)Se2 태양전지에 수분이 미치는 영향)

  • Yang, So Hyun;Bae, Jin A;Song, Yu Jin;Jeon, Chan Wook
    • Current Photovoltaic Research
    • /
    • v.5 no.4
    • /
    • pp.135-139
    • /
    • 2017
  • We fabricated two different transparent conducting oxide thin films of ZnO doped with Ga ($Ga_2O_3$ 0.9 wt%) as well as Al ($Al_2O_3$ 2.1 wt%) (GAZO) and ZnO doped only with Al ($Al_2O_3$ 3 wt%) (AZO). It was investigated how it affects the moisture resistance of the transparent electrode. In addition, $Cu(In,Ga)Se_2$ thin film solar cells with two transparent oxides as front electrodes were fabricated, and the correlation between humidity resistance of transparent electrodes and device performance of solar cells was examined. When both transparent electrodes were exposed to high temperature distilled water, they showed a rapid increase in sheet resistance and a decrease in the fill factor of the solar cell. However, AZO showed a drastic decrease in efficiency at the beginning of exposure, while GAZO showed that the deterioration of efficiency occurred over a long period of time and that the long term moisture resistance of GAZO was better.

Characteristics of Grounding Impedances of Carbon Compound Grounding Electrodes (탄소혼합물 접지전극의 접지임피던스의 특성)

  • Lee, Kang-Soo;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.54-60
    • /
    • 2011
  • This paper presents characteristics of frequency-dependent grounding impedance and transient grounding impedance for the carbon compound grounding electrode used in the installation of computerized electronic equipment and lightning protection system. The frequency-dependent grounding impedances were measured by applying sinusoidal currents in the frequency range from 100 [Hz] to 10[MHz], and the transient grounding impedances were examined by subjecting the impulse current with the front-time between 1~80[${\mu}s$]. As a result, the ground resistance of the carbon compound grounding electrode is less than that of another type grounding electrodes. The transient grounding impedance is relatively low and the conventional grounding impedance is rather lower than the ground resistance. The frequency-dependent grounding impedance of the carbon compound grounding electrode is capacitive and the grounding impedance is decreased with increasing the frequency of injected currents. Therefore in the case that the carbon compound grounding electrode is jointly used with large-scaled grounding electrodes, it is possible to reduce the high frequency grounding impedance of the integrated grounding electrode system.

Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition (부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구)

  • 차기철;손정민;김기진;최승훈
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF