1 |
Task Force of the Eourpean Society of Cardiology and the North American Society of Pacing and Electrophysiology, “Heart Rate Variability: Standards of Measurement,” Physiological Interpretation, and Clinical Use, 93 1996.
|
2 |
C.Jing, et al, “The Research on Emotion Recognition from ECG Signal,” International Conference on Information Technology and Computer Science, pp. 497-500, 2009.
|
3 |
A.Haag, et al, “Emotion Recognition Using Bio-Sensors: First Steps Towards an Automatic System,” Proceedings of the Kloster Irsee Tutorial and Research workshop on Affective Dialogue Systems, pp.36-48, 2004.
|
4 |
Rigas, et.al, “A User Independent, Biosignal Based, Emotion Recognition Method,” Lecture notes in Computer Science, No.4511, pp.314-318, 2007
DOI
ScienceOn
|
5 |
A. C-W. Wong, et al, “A 1V Micropower Systemon-Chip for Vital-Sign Monitoring in Wireless Body Sensor Networks,” ISSCC Dig. Tech. Papers, pp.138-139, Feb., 2008.
|
6 |
J. Yoo, et.al, “A Wearable ECG Acquisition System With Compact Planar-Fashionable Circuit Board- Based Shirt,” IEEE Transactions on Information Technology in Biomedicine, Vol.13, pp.892-902, 2009.
DOI
ScienceOn
|
7 |
E.M. Spinelli, et.al, “A Transconductance Driven-Right-Leg Circuit,” IEEE Transactions on Biomedical Engineering, Vol.47, pp.1466-1470, 1999.
DOI
ScienceOn
|
8 |
S.N. Pocock, “Earth-free patient monitoring, Part 1: principles, practice and hazards,” Biomed. Eng., Vol.7, pp.21-25, 1972.
|
9 |
E.M. Spinelli, et.al, “Two-Electrode biopotential measurements: Power line interfere Analysis,” IEEE Transaction on biomedical engineering, Vol. 52, pp.1436-442, Aug. 2005.
DOI
ScienceOn
|
10 |
Fact sheet for obesity and cardiovascular disease: A report from the American Heart Association, 2009.
|
11 |
D. Jabaudon, et.al, “Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack,” Stroke, J.Amer. Heart Assoc., Vol.35, pp.1647-1651, May, 2004.
|
12 |
K.N.Leung and P.K.T.Mok, “A CMOS Voltage Reference based pm weighted for CMOS Low-Dropout Linear Regulators,” IEEE Journal of Solid-State Circuits, Vol.38, pp.146-150, Jan., 2003.
DOI
ScienceOn
|
13 |
D.E.Wood, et.al, “Comparative analysis of powr line interference between two-or three-electrode biopotential amplifiers,” Medical & Biological Engineering & Computing, Vol.33, pp.63-68, 1995.
DOI
|
14 |
N.V. Thakor, et.al, “Ground-free ECG Recording with Two Electrodes,” IEEE Transaction on biomedical engineering, Vol.BME-27, pp.699-704, Dec. 1980.
DOI
ScienceOn
|
15 |
K. Hachisuka, et al, “Development and performance analysis of an intra-body communication device,” in Int. Solid-State Sens., Actuators, Microsyst. Conf., pp.1722-1725, 2003.
|
16 |
George E. Bergey, et al, “Electrocardiogram recording with pasteless electrodes,” IEEE Trans. on Bio-medical Engineering, Vol.18, pp.206-211,1971.
DOI
|
17 |
Long Yan, et al, “A Two-Electrode 2.88nJ/Conv. Biopotential Acquisition System for Portable Healthcare Device,” Proc. Of the IEEE Asian Solide-State Circuit Conference (A-SSCC), pp.329- 332, Nov., 2008.
|
18 |
Refet Firat Yazicioglu, Chris Van Hoff, et.al, “A 60 uW 60 nV/srtHz Redout Front-End for Portable Biopotential Acquisition Systems,” IEEE Journal of Solid-State Circuits, Vol.42, pp.1100-1109, May., 2007.
DOI
ScienceOn
|
19 |
Christian C. ENZ and Gabor C. Temes, “Circuit Techniques for Reducing the Effects of Op-Amp Imperfections: Autozeroing, Correlated Double Sampling, and Chopper Stablization,” Proc. IEEE, Vol.84, pp.1584-1614, Nov., 1996.
DOI
ScienceOn
|
20 |
Datasheet of INA321, Simplified ECG Circuit for Medical Applications. Available : http://focus.ti.com/lit/ds/sbos168d/sbos168d.pdf
|
21 |
E.Rodriguez-Cruz, Hypertension : Overview-eMedicine. Available : http://emedicine.medscape.com/article/889877-overview
|