• 제목/요약/키워드: friction heat

검색결과 947건 처리시간 0.029초

서보모터방식 마찰용접을 이용한 TiAl 합금과 SCM440의 접합에 미치는 용접조건의 영향 (Effects on the Joining Condition of TiAl Alloy and SCM440 by Servo Motor Type Friction Welding)

  • 박종문;김기영;김경균;오명훈
    • 열처리공학회지
    • /
    • 제29권2호
    • /
    • pp.66-74
    • /
    • 2016
  • In this study, characteristics of TiAl alloy and SCM440 (Cr-Mo steel) have been investigated with the various joining condition by servo motor type friction welder. The experimental factors of friction welder used in this study are spindle revolution, friction speed, and distance, upset speed and distance, respectively. Servo motor type friction welder could be controlled by the level of oil pressure, and it could be performed by position control dependence of electrical energy. Mechanical properties and morphology of welded interface were characterized by various joining condition. This aroused due to the bond strength dependence on friction heat and size of the heat affected zone. Therefore, it is necessary to have enough friction heat and decreased heat affected zone for good friction welding between dissimilar metals. An optimum bond was obtained between TiAl alloy and SCM440 by controlling friction speed and distance. At the spindle revolution 4,000 rpm, friction speed 120 mm/min, friction distance 15 mm, the bond strength was found to be 312 MPa.

A2024 와 SM45C 마찰용접의 열전달 해석 (Heat Transfer Analysis of Friction Welding of A2024 to SM45C)

  • 이상윤;윤병수
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.65-70
    • /
    • 2001
  • The hear transfer mechanism initiating the friction welding is examined and a transient three dimensional heat conduc-tion model for the welding of two dissimilar cylindrical metal bars is investigated. The cylindrical metal bars are made of materials made of A2024 and SM 45C. Numerical simulations of heat flow are performed using the finite volume method. Respectively. Commercial FLUENT code is used in the heat flow simulation and maximum temperature and distribution of temperature are calculated. Temperature of friction welded joining face is compared with the temperature distribution measured by experiment and numerical simulation. The maximum temperature of friction welded joining face is lower than melting point of A2024-T6 aluminum alloy using insert metal. The temperature distribution of friction welded join- ing face with insert metal is more uniform than that of without inset metal.

  • PDF

Cu-Al 마찰용접 접합부 계면에서 열처리에 따른 금속간화합물 성장 (Growth of Intermetallic Compounds by Heat Treatment at Interface of Friction Welded Al-Cu System)

  • 김기영;최인철;;오명훈
    • 열처리공학회지
    • /
    • 제32권2호
    • /
    • pp.79-85
    • /
    • 2019
  • To investigate the influence of heat treatment on the growth intermetallic compounds (IMCs) at the joint interface of friction-welded Cu-Al, several heat treatments are performed at three different temperature with different times. The experiments reveal three different IMCs layers which are significantly influenced by atomic diffusion of Cu and Al with heat treatment conditions. Since the formation of these IMCs layers can affect mechanical properties of friction-welded Cu-Al interfaces, the relationship between the microstructure of IMCs layers and the tensile strength is analyzed according to heat treatment temperature and times.

확대 채널에서 확대율이 열전달과 마찰계수에 미치는 효과 (Effect of Divergence Ratio on Heat Transfer and Friction Factor in the Diverging Channel)

  • 오세경;이명성;정성수;안수환
    • 동력기계공학회지
    • /
    • 제17권1호
    • /
    • pp.64-70
    • /
    • 2013
  • The heat transfer and friction factor characteristics of turbulent flows in three stationary channels have been investigated experimentally to check out the effect of divergence ratio. These are a constant cross-sectional channel and two diverging channels with ratio of divergence(Dho/Dhi) of 1.16 and 1.49. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000 and the dimension of uniform cross-sectional test section is $100mm{\times}100mm$ at the cross section and 1,000 mm in length. The measurements of heat transfer coefficients and friction factors in the uniform channels were conducted as a reference. Because of the streamwise flow deceleration, the heat transfer and friction factor characteristics in the diverging channel were quite different from those of the constant cross-sectional channel. The effective friction factors and convective heat transfer coefficients increased with increasing the ratio of divergence of the channel.

VM사이클 히트펌프 기초 설계프로그램 (Basic Simulation for Vuilleumier Cycle Heat Pump)

  • 박병덕
    • 한국산업융합학회 논문집
    • /
    • 제3권3호
    • /
    • pp.265-273
    • /
    • 2000
  • Basic simulation program for Vuilleumier cycle heat pump was developed that can use precise VMHP design and analysis. VMHP system was divided 11 sections in simulation. Simulation was used adiabatic model analysis and that considered with heat transfer performance for heat exchanger, regenerator loss, conduction loss, shuttle loss, pumping loss and pressure loss by flow friction. Specially, friction loss of connection pipe between heat compression side and heat pump side, leakage of rod seal and piston seal was considered in the analysis.

  • PDF

구리와 알루미늄 이종금속 판재간의 전기저항가열 표면마찰 스폿용접 특성 (Characteristics of Electric Resistance Heated Surface Friction Spot Welding Process of Copper and Aluminum Dissimilar Metal Sheets)

  • 순샤오광;진인태
    • 한국기계가공학회지
    • /
    • 제21권8호
    • /
    • pp.99-109
    • /
    • 2022
  • In this study, an electric resistance-heated surface friction spot-welding process was proposed and tested for the spot-welding ability of copper and aluminum dissimilar metal sheets using electric resistance heating and surface friction heating. This process has welding variables, such as the current value, energizing cycles, rotational speed, and friction time. The current value and energizing cycle can affect the resistance heat, and the rotational speed of the rotating pin and friction time influence frictional heat generation. Resistance heating before friction heating has a preheating effect on the Cu-Al contact interface and a positive effect on preventing friction heat loss during the friction stage. However, because resistance preheating can soften the copper sheet and affect the contact stress and friction coefficient, it has difficulties that may adversely affect frictional heat generation. Therefore, the optimal combination of welding variables should be determined through simulations and experiments of the spot-welding process to determine the effects of electric resistance preheating on the suggested process. Through this procedure, it is known that the proposed spot-welding process can improve the welding quality during the spot welding of Cu-Al sheets.

회주철의 마찰용접 특성에 관한 연구 - 입열량 이론식을 중심으로 - (Friction Weldability of Grey Cast Iron - by the Concept of Friction Weld Heat Input Parameter -)

  • 정호신;방국수
    • Journal of Welding and Joining
    • /
    • 제32권3호
    • /
    • pp.95-101
    • /
    • 2014
  • Joining of grey cast iron by fusion welding has much difficulties for its extremely low ductility and low toughness because of the flake form of the graphite. And the brittle microstructure, i.e. ledeburite may be formed during fusion welding by its rapid cooling rates. By these kinds of welding problem, preheat and post heat treatment temperature must be increased to avoid weld crack or welding problems. In order to avoid these fusion welding problem, friction welding of cast iron was carried out for improving joint soundness, establishing friction welding variables. There is no factor for evaluating friction weldability in continuous drive type friction welding. In this point of view, this study proposed the parameters for calculating friction weld heat input. The results obtained are as follows ; 1. There was a close relationship between tensile strength and flash appearance of friction welded joint. 2. Tensile strength was decreased and flash was severely oxidized as increasing frictional heating time. 3. As increased forging pressure $P_2$, flash had a large crack and tensile strength was decreased. 4. As powdered graphite by rotational frictional force induced flat surface and hindered plastic flow of metal, tensile strength of welded joint was decreased. 5. Heat input for continuous drive type friction welding could be calculated by the factors of $P_1$, $P_2$ and upset distance(${\delta}$).

아이스 슬러리의 수송 및 냉열이용에 관한 연구 (A Study on Transport and Heat Utilization of Ice Slurries)

  • 길복임;이윤표;정동주;조봉현;최은수
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1065-1071
    • /
    • 2001
  • To investigate hydraulic and thermal characteristics of ice slurries in a circular tube, ice slurries were tested in a flow loop with a constant heat flux test section, for ranges of flow velocity, ice fraction and heat flux. Heat transfer coefficients and friction factors of ice slurries were calculated by measuring the outer wall temperatures of the test section and the pressure drops over the test section. Heat transfer coefficients of ice slurries were 9% higher than the heat transfer coefficients expected by Petukhov. Friction factors were about 4% lower than the friction factors expected by Petukhov. The effective thermal capacity of ice slurry with 12.8% ice fraction, was found to be about 3 times higher than the thermal capacity of water.

  • PDF

핀-관 열교환기의 난방운전 시 공기측 열전달 및 마찰특성 (Air-side Heat Transfer and Friction Characteristics of Fined-tube Heat Exchangers under Heating Condition)

  • 권영철;장근선;고국원;김영재;박병권
    • 공업화학
    • /
    • 제17권5호
    • /
    • pp.476-482
    • /
    • 2006
  • 본 연구에서는 핀-관 열교환기의 공기측 열전달 및 마찰특성을 조사하기 위하여 8종의 열교환기에 대하여 난방조건에서 실험을 수행하였다. 핀-관 열교환기의 성능 비교평가를 위하여 공기엔탈피식 칼로리미터를 이용하였다. 실험에 사용된 핀은 슬릿, 루버, 평판형이며, 관경은 7.0 mm, 열수는 1, 2, 3열 그리고 4종의 관회로에 대해 j 계수와 마찰계수를 획득하였다. 실험을 통해서 핀형상, 핀피치, 열수 그리고 관회로의 변화에 대한 핀-관 열교환기의 공기측 열전달 및 마찰거동을 조사하였다. 실험결과는 관회로의 구성이 열교환기의 열전달과 마찰과 관련이 있음을 보여주었다. 동일 핀피치의 열교환기의 경우에 저 Re 수에서는 1열의 열전달성능이 우수하나 Re 수가 증가할수록 j 계수의 거동은 역전함을 보였다. 그리고 2열의 열교환기에서 핀종류에 따라 공기측 열전달성능과 마찰계수가 다르게 나타남을 확인하였다.

Heat Transfer and Friction Behaviour in a Channel with an Inclined Perforated Baffle

  • Krishna Putra, Ary Bachtiar;Ahn, Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.70-76
    • /
    • 2008
  • The effects of the inclined perforated baffles on the distributions of the local heat transfer coefficients and friction factors for air flows in a rectangular channel were determined for Reynolds numbers from 23,000 to 57,000. Four different types of the baffle are used. The inclined baffles have the width of 19.8cm, the square diamond type hole having one side length of 2.55cm, and the inclination angle of $5^{\circ}$, whereas the corresponding channel width-to-height ratio was 4.95. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle, and the heat transfer performance of baffle type II (3 hole baffle) has the best value.