• 제목/요약/키워드: fresh concrete

검색결과 660건 처리시간 0.062초

굳지 않은 콘크리트의 간극통과거동 (The Behavior of Fresh Concrete to Pass between Bars)

  • 오상균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.97-102
    • /
    • 2002
  • The ability to pass between bars is one of the most important performance of self-compacting concrete or high-flowability concrete since it determines the final filling capacity which influences the strength and durability of hardened concrete in structure. Therefore it has been evaluated by many researchers using different kinds of testing apparatuses. The assessments of passing ability, however, differ largely according to the style, the dimension and the criteria in apparatuses, and the value obtained from one apparatus cannot be converted those of the others. There needs a rheological approach to the better understanding of the passing behavior of fresh concrete between reinforcing bars, where the flow velocity of concrete becomes slow and the blockade sometimes occurs due to the interference between aggregates and reinforcing bars. Experimental works were conducted to clarity the effects of the clearance between reinforcing bars, the volume of aggregate and the rheological properties of matrix on the behavior from the rheological point view and showed the rational mix proportioning of concrete.

  • PDF

수중 불분리성 콘크리트의 부착 강도 특성에 관한 연구 (Bond Strength Properties of Antiwashout Underwater Concrete)

  • 김명식;김기동;윤재범
    • 콘크리트학회논문집
    • /
    • 제12권1호
    • /
    • pp.89-99
    • /
    • 2000
  • The objective of this study is to investigate the bond strength properties of antiwashout underwater concrete. The arrangement of bars (vertical bar, horizontal upper bar, horizontal lower bar), condition of casting and curing (fresh water, sea water), type of fine aggregate (river sand, blended sand(river sand : sea sand = 1:1), and proportioning strength of concrete (210, 240, 270, 300, 330kgf/$\textrm{cm}^2$)are chosen as the experimental parameters. The test results(ultimate bond stress) are compared with bond and development provisions of the ACI Building Code(ACI 318-89) and proposed equations from previous research(which was proposed by Orangun et. al). The experimental results show that ultimate bond stress of antiwashout underwater concrete which arranged bar on the horizontal lower, used the blend sand, and was cast and cured in the fresh water are higher that other conditions. The ultimate bond stress were increased in proportion to {{{{( SQRT {fcu }) }}3 2. From this study, rational analytic formula for the ultimate bond stress are to be from compressive strength of concrete.

조수에 의한 콘크리트 침식방지법에 관한 연구(ll) (Studies on Preventive Methods Against Concrete Corrosion by Sea Water (ll))

  • 고재군
    • 한국농공학회지
    • /
    • 제15권2호
    • /
    • pp.3018-3030
    • /
    • 1973
  • 이 연구는 해수작용에 대한 콘크리트의 내구성시험의 일환으로 각종 배합설계의 콘크리트에 대하여 1년간 실내에서 해수에 침지하여 압축강도와 부식율을 규명하고저 시도하였다. 각종 콘크리트의 배합설계에 있어서 보통시멘트만을 사용한 것, 혼화제로서 후라이애쉬, 포조리스, 빈솔레진 등을 각각 보통시멘트에 사용한 것, 그리고 포조란 시멘트만을 사용한 것 등으로 구분하고 각 콘크리트 공시체는 K.S 규정에 준하여 만들어 재령 7일 및 28일 양생하였다. 그리고 압축강도시험은 수중과 해수에 각각 1년간 침지한 것에 대하여 강도를 측정하고 부식율시험은 해수중에 1년간 침지한 것에 대하여 부식율을 측정하였다. 이와같은 콘크리트의 압축강도시험과 부식율 시험에 대한 결과를 요약하면 다음과 같다. (1) 압축강도에 있어서 보통콘크리트는 수중이나 해수중에 다 같이 다른 콘크리트의 강도보다 낮으므로 포조란시멘트나 혼화제인 후라이애쉬, 포조리스. 빈솔레진은 각각 그 효과가 인정되었다. (2) 포조란시멘트는 수중에서 강도가 다른 콘크리트보다 가장 높았으나 해수중에서는 후라이애쉬보다 낮은 강도를 나타내었다. 따라서 포조란시멘트는 해수중에서 보다 수중에서 강도상 효과가 있다는 것을 알 수 있다. (3) 후라이애쉬는 수중에서와 해수중에서 다 같이 장기강도에 있어서 높은 강도를 갖인 특성이 있다는 것을 나타내었고, 수중에서는 포조란시멘트에 비하여 강도가 낮었으나 해수중에서는 오히려 포조란 시멘트의 강도를 능가하고 있어 해수중에서는 포조란 시멘트보다 강도상 더욱 그 효과가 크다는 것을 알 수 있다. (4) 포조리스는 후라이애쉬와 포조란시멘트에 비해서 그 효과가 떨어지나 빈솔레진에 비해서는 강도상에 있어서 항상 그 효과가 인정되공 있다. (5) 빈솔레진은 포조란시멘트나 혼화제중에서 강도상 가장 그 효과가 낮으나 보통콘크리트에 비하면 그 효과는 수중이나 해수중에서 다 같이 인정되고 있다. (6) 콘크리트의 압축강와 흡수율과의 관계는 후라이애쉬를 제외하면 다른 재령에서와 같이 흡수율이 적을수록 압축강도는 증가되며 회기직선관계가 성립되었다. 그러나 후라이애쉬는 장기강도에서 그 특징이 현저히 나타나고 있어 다른 콘크리트의 흡수율에 비하여 현저히 높은 강도를 나타내고 있다. (7) 부식율에 있어서는 1년간 해수작용을 받었을 때 각 콘크리트의 유의적인 부식율이 인정될 수 없으며 외관상에서도 부식현상을 식별할 수 없었다.

  • PDF

신ㆍ구 콘크리트 접착제의 시공조건에 따른 성능 (Performance of Adhesives for Bonding Fresh Concrete to Hardened Concrete under Application Conditions)

  • 이찬영;심재원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 2002
  • In vertical construction joint, adhesives such as epoxy, acrylic, latex, etc. have been usually used for bonding fresh concrete to hardened concrete. In this study, performance of adhesives under various application conditions was investigated through tests for slant shear and flexural strength. From the results of the tests, it is found that superior bonding performance can be obtained under good surface preparation without adhesive when high strength concrete is used.

  • PDF

양생초기의 진동시간 제어에 따른 콘크리트의 강도 변화 (Variation of Concrete Strength according to Vibration Time Control for Fresh Concrete)

  • 송규황;김종수;김명식;장희석;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.675-678
    • /
    • 2003
  • Experimental results for variation of concrete strength according to vibration time control for fresh concrete were given. Vibration velocity, time before vibration and vibrating time were used as experimental parameters. Compressive strength, split tensile strength, ana bond strength were investigated and then fracture surfaces of split tensile strength specimen were observed. From the experimental results, it could be concluded that there may be no decrease in concrete strengths if time before vibration will be sustained at least for more than 3 hours.

  • PDF

초기재령 콘크리트의 응결특성 모델링 (Modeling of the Setting Characteristics of Early-age Concrete)

  • 조호진;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.391-396
    • /
    • 2002
  • The so called setting is defined as the onset of rigidity in fresh concrete. In the analysis of the early-age concrete behavior, we consider fresh concrete as a structural element immediately after mixing. But for the activation of real structural behavior of fresh concrete, it takes some time after the beginning of hydration reaction. So, the very early age deformations due to hydration heat and shrinkage which occur before the setting do not produce restraint stresses. In this paper, we propose a setting characteristic model based on the so called percolation theory. From the analysis using the model, the influence of curing temperature is investigated and analytical results are compared with experimental results. From the comparison, the validity of proposed model is verified. This model is also applied to evaluate stress development in a temperature-stress test machine (TSTM) specimen and then the effect of setting time on the stress development is discussed.

  • PDF

콘크리트 측압에 대한 더블 데크플레이트 벽체 거푸집의 안전성 평가 (Safety Assessment of Double Deck Plate Wall Formwork against Lateral Pressure of Fresh Concrete)

  • 이혜지;문주현;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.225-226
    • /
    • 2023
  • This study examined the lateral deformation of double deck plate wall formworks against the lateral pressure of fresh concrete and then compared with the construction specification.

  • PDF

Effect of metakaolin on the properties of conventional and self compacting concrete

  • Lenka, S.;Panda, K.C.
    • Advances in concrete construction
    • /
    • 제5권1호
    • /
    • pp.31-48
    • /
    • 2017
  • Supplementary cementitious materials (SCM) have turned out to be a vital portion of extraordinary strength and performance concrete. Metakaolin (MK) is one of SCM material is acquired by calcinations of kaolinite. Universally utilised as pozzolanic material in concrete to enhance mechanical and durability properties. This study investigates the fresh and hardened properties of conventional concrete (CC) and self compacting concrete (SCC) by partially replacing cement with MK in diverse percentages. In CC and SCC, partial replacement of cement with MK varies from 5-20%. Fresh concrete properties of CC are conducted by slump test and compaction factor tests and for SCC, slump flow, T500, J-Ring, L-Box, V-Funnel and U-Box tests. Hardened concrete characteristics are investigated by compressive, split tensile and flexural strengths at age of 7, 28 and 90 days of curing under water. Carbonation depth, water absorption and density of MK based CC and SCC was also computed. Fresh concrete test results indicated that increase in MK replacement increases workability of concrete in a constant w/b ratio. Also, outcomes reveal that concrete integrating MK had greater compressive, flexural and split tensile strengths. Optimum replacement level of MK for cement was 10%, which increased mechanical properties and robustness properties of concrete.

플라이애쉬를 혼입한 굳지않은 수중불분리성 콘크리트의 특성에 관한 연구 (The Characteristic of Fresh Properties of Antiwashout Underwater Concrete with Variation of Fly Ash)

  • 정병훈;최병우;장희석;김명식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.41-46
    • /
    • 2000
  • In recently, though the development of antiwashout admixture, if's possible to construct in underwater with the concrete which is improved segregation resistance of material, filling and self-leveling. It is generally to use this method with Europe and Japan as the central figure, and also the construction case is reported in korea. There's some advantages to add the fly ash in plain concrete. The objective of this study is to find the characteristics of fresh underwater antiwashout concrete which is followed by the blend rate of fly ash.

  • PDF

경화 전 콘크리트의 염소이온 신속측정 페이퍼 센서 개발에 관한 실험적 연구 (Rabid detection of chloride ions in fresh concrete using a chromium-free paper-based analytical device (µPAD) )

  • 카르틱 수비아;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.123-124
    • /
    • 2023
  • This study successfully developed a chromium-free paper-based analytical device (µPAD) for chloride detection in fresh concrete. The sensing materials were chemically synthesized and coated to the paper through drop casting. The fabricated µPAD was thoroughly tested with various concentrations of chloride ions. Upon interaction with the µPAD, the chloride ions in the solution react with a chromium-free silver compound, exhibiting a specific coloring height proportional to the absolute chloride concentration. The height of the color change during a reaction can vary based on the chloride concentration, which allows for predicting the chloride concentration in a solution. The results reveal that µPAD has extraordinary precision in identifying chloride in fresh concrete, which highlights its immense potential for future applications.

  • PDF