• Title/Summary/Keyword: frequency of using

Search Result 31,371, Processing Time 0.073 seconds

The Important Frequency Band Selection and Feature Vecotor Extraction System by an Evolutional Method

  • Yazama, Yuuki;Mitsukura, Yasue;Fukumi, Minoru;Akamatsu, Norio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2209-2212
    • /
    • 2003
  • In this paper, we propose the method to extract the important frequency bands from the EMG signal, and for generation of feature vector using the important frequency bands. The EMG signal is measured with 4 sensor and is recorded as 4 channel’s time series data. The same frequency bands from 4 channel’s frequency components are selected as the important frequency bands. The feature vector is calculated by the function formed using the combination of selected same important frequency bands. The EMG signals acquired from seven wrist motion type are recognized by changing into the feature vector formed. Then, the extraction and generation is performed by using the double combination of the genetic algorithm (GA) and the neural network (NN). Finally, in order to illustrate the effectiveness of the proposed method, computer simulations are done.

  • PDF

Series Resonant ZCS- PFM DC-DC Converter using High Frequency Transformer Parasitic Inductive Components and Lossless Inductive Snubber for High Power Microwave Generator

  • Kwon, Soon-Kurl;Saha, Bishwajit;Mun, Sang-Pil;Nishimura, Kazunori;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.18-25
    • /
    • 2009
  • Conventional series-resonant pulse frequency modulation controlled DC-DC high power converters with a high-frequency transformer link which is designed for driving the high power microwave generator has the problem of hard switching commutation at turn-on and turn-off of active power switching devices. This problem is due to the influence of the magnetizing current of the high-frequency transformer. This paper presents a novel prototype for a high-frequency transformer using parasitic parameters with a lossless inductive snubber and a series resonant capacitor assisted series-resonant zero current switching pulse frequency modulated DC-DC power converter, which is designed using a high power magnetron for microwave ovens. In order to implement a complete and efficient soft switching commutation, the performance of the new converter topology is practically confirmed and evaluated in the prototype of a power microwave generator.

Thinning algorithm of hand-printed korean character using wavelet transform (웨이브렛 변환을 이용한 필기체 한글 문자의 세선화 알고리즘)

  • 길문호;유기형;박정호;최재호;곽훈성
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.745-748
    • /
    • 1998
  • Recently, image and voice processing part is using wavelet transform. We propose thining algorithm using wavelet tranform. Wavelet transform consists of low frequency and high frequency in the spatial and frequency domain. After the wavelet decomposition, more than 90 percents of energy are contained in lowest frequency band. Therefor, for images with large difference of gray value between foreground and background like character images, we can more accurately in the lowest frequency band. Lowest frequency band has wavelet transform significant coefficient(WTS) that is required for the thinning algorithm we proposed Paper [3][5][7][8] can not separate consonants and vowels of korean characters. Becuase korean characters have structural feature. This paper can separate consonants and vowels. Simulation executed low frequency image and data compression can reduce 1/4$^{n}$ with level n. we can redcue time complexity 3/8.

  • PDF

Zooplankton Biomass and Size Estimation Using a Multi-frequency Acoustic System (고주파 다주파 음향시스템을 이용한 동물성 플랑크톤의 크기별 생물량 추정)

  • Hwang, Bo-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.1
    • /
    • pp.54-60
    • /
    • 2008
  • High- and multi-frequency acoustic systems can measure a zooplankton patch successively and estimate the spatial distribution and abundance of zooplankton according to size using a multi-frequency inversion (MFI) method. This study measured zooplankton distribution to a depth of 150m using a multi-frequency acoustic system (TAPS-6), installed on a CTD system with a fluorometer and analyzed it using the MFI method. Simultaneously, zooplankton samples were collected by north pacific standard (NORPAC) net to confirm the species composition. The results showed that the combined method is valuable for estimating the zooplankton profile in detail and investigating the relationship between the zooplankton and phytoplankton profiles.

Frequency Analysis on KEPCO Power System Using Dynamic Load Shedding Model (동적부하차단 모델을 이용한 KEPCO 계통의 주파수 해석)

  • Jang, B.T.;Lee, S.Y.;Kim, K.H.;Chu, J.B.;Oh, H.J.;Cho, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.121-122
    • /
    • 2002
  • When a power system experiences a serious disturbance on insufficient power, the system frequency may drop. For system frequency will be maintain standard value, under_frequency relay will reconstruct balance of power and load by load shedding. Currently load shedding scheme is due to establishment plan by fixed scenario. Where compare current scheme with past scheme, system frequency should be recovered by load shedding using rate of frequency decline. This paper suggests the dynamic load shedding scheme by using the rate of change of frequency when The Korea Electric power system is happened the large disturbance.

  • PDF

Frequency Estimation Technique using Recursive Discrete Wavelet Transform (반복 이산 웨이브릿 변환을 이용한 주파수 추정 기법)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.76-81
    • /
    • 2011
  • Power system frequency is the main index of power quality indicating an abnormal state and disturbances of systems. The nominal frequency is deviated by sudden change in generation and load or faults. Power system is used as frequency relay to detection for off-nominal frequency operation and connecting a generator to an electrical system, and V/F relay to detection for an over-excitation condition. Under these circumstances, power system should maintain the nominal frequency. And frequency and frequency deviation should accurately measure and quickly estimate by frequency measurement device. The well-known classical method, frequency estimation technique based on the DFT, could be produce the gain error in accuracy. To meet the requirements for high accuracy, recently Wavelet transforms and analysis are receiving new attention. The Wavelet analysis is possible to calculate the time-frequency analysis which is easy to obtain frequency information of signals. However, it is difficult to apply in real-time implementation because of heavy computation burdens. Nowadays, the computational methods using the Wavelet function and transformation techniques have been searched on these fields. In this paper, we apply the Recursive Discrete Wavelet Transform (RDWT) for the frequency estimation. In order to evaluate performance of the proposed technique, the user-defined arbitrary waveforms are used.

A Novel Auxiliary Edge-Resonant Snubber-Assisted Soft Switching PWM High Frequency Inverter with Series Capacitor Compensated Resonant Load for Consumer Induction Heating

  • Ahmed Nabil A.;Iwai Toshiaki;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.95-103
    • /
    • 2006
  • In this paper, a novel prototype of auxiliary switched capacitor assisted voltage source soft switching PWM Single-Ended Push Pull (SEPP) series capacitor compensated load resonant inverter with two auxiliary edge resonant lossless inductor snubbers is proposed and discussed for small scale consumer high-frequency induction heating (IH) appliances. The operation principle of this inverter is described by using switching mode equivalent circuits. The newly developed multi resonant high-frequency inverter using trench gate IGBTs can regulate its output AC power via constant frequency edge-resonant associated soft switching commutation by using an asymmetrical PWM control or duty cycle control scheme. The brand-new consumer IH products which use the newly proposed edge-resonant soft switching PWM-SEPP type series load resonant high-frequency inverters are evaluated using power regulation characteristics, actual efficiency vs. duty cycle and input power vs. actual efficiency characteristics. Their operating performance compared with some conventional soft switching high-frequency inverters for IH appliances is discussed on the basis of simulation and experimental results. The practical effectiveness of the newly proposed soft switching PWM SEPP series load resonant inverter is verified from an application point of view as being suitable for consumer high-frequency IH appliances.

Single Phase Utility Frequency AC-High Frequency AC Matrix Converter Using One-Chip Reverse Blocking IGBTs based Bidirectional Switches

  • Hisayuki, Sugimura;Kwon, Soon-Kurl;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.125-128
    • /
    • 2006
  • This paper presents a novel type soft switching PWM power frequency AC-AC converter using bidirectional active switches or single phase utility frequency AC-high frequency AC matrix converter. This converter can directly convert utility frequency AC (UFAC, 50Hz/60Hz) power to high frequency AC (HFAC) power ranging more than 20kHz up to 100kHz. A novel soft switching PWM prototype of high frequency multi-resonant PWM controlled UFAC-HFAC matrix converter using antiparallel one-chip reverse blocking IGBTs manufactured by IXYS corp. is based on the soft switching resonance with asymmetrical duty cycle PWM strategy. This single phase UFAC-HFAC matrix converter has some remarkable features as electrolytic capacitor DC busline linkless topology, unity power factor correction and sine-wave line current shaping, simple configuration with minimum circuit components, high efficiency and downsizing. This series load resonant UFAC-HFAC matrix converter, incorporating bidirectional active power switches is developed and implemented for high efficiency consumer induction heated food cooking appliances in home uses and business-uses. Its operating performances as soft switching operating ranges and high frequency effective power regulation characteristics are illustrated and discussed on the basis of simulation and experimental results.

  • PDF

A Study on the Optimum Design of Charge Pump PLL for High Speed and Fast Acquisition (고속동작과 빠른 Acquisition 특성을 가지는 Charge Pump PLL의 최적설계에 관한 연구)

  • Woo, Young-Shin;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.718-720
    • /
    • 1999
  • This paper describes a charge pump PLL architecture which achieves high frequency operation and fast acquisition. This architecture employs multi-phase frequency detector comprised of precharge type phase frequency detector and conventional phase frequency detector. Operation frequency is increased by using precharge type phase frequency detector when the phase difference is small and acquisition time is shortened by using conventional phase frequency detector and increased charge pump current when the phase difference is large. By virtue of this multi-phase frequency detector structure, the maximum operating frequency of 694MHz at 3.0V and faster acquisition were achieved by simulation.

  • PDF

A comparison between digital algorithms for estimation of power system frequency (계통 주파수 추정을 위한 디지털 알고리즘 간의 비교)

  • Lee, B.H.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.276-277
    • /
    • 2006
  • Estimation of power system frequency is an important task because frequency deviation is a good indicator of the system abnormal operating conditions. The algorithms, curve fitting, technique using Taylor series, deviation of phasor angle of fundamental waveform using DFT (Discrete Fourier Transform) and Prony method, are tested under operation of the frequency relaying by using EMTP MODELS. The performance of methods is compared with the simulation results.

  • PDF