• 제목/요약/키워드: frequency of exceeding

검색결과 108건 처리시간 0.024초

산업장 소음의 강도 및 주파수 특성에 관한 조사연구 (The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites)

  • 김광종;차철환
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF

Probability of exceeding the serviceability limit of antenna masts

  • Kammel, Christian
    • Wind and Structures
    • /
    • 제4권4호
    • /
    • pp.353-366
    • /
    • 2001
  • With respect to serviceability, antenna masts should be designed so that wind-induced motion will not cause unacceptable lack of transmission for broadcasting users and wireless communication. For such antenna masts with directional radio transmission the serviceability limit state is predominantly governed by the tolerable change of the broadcasting angle of the mounted antenna assembly and therefore by the tip distortion of the mast. In this paper it will be shown that refinements of the present state of design of antenna masts are possible by using the statistics of extremes applied to extreme wind situations and by consideration of the statistical and reliability requirements given by the operator such as frequency and return period of passing the serviceability limit.

Probabilistic seismic evaluation of buckling restrained braced frames using DCFD and PSDA methods

  • Asgarian, Behrouz;Golsefidi, Edris Salehi;Shokrgozar, Hamed Rahman
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.105-123
    • /
    • 2016
  • In this paper, using the probabilistic methods, the seismic demand of buckling restrained braced frames subjected to earthquake was evaluated. In this regards, 4, 6, 8, 10, 12 and 14-storybuildings with different buckling restrained brace configuration (including diagonal, split X, chevron V and Inverted V bracings) were designed. Because of the inherent uncertainties in the earthquake records, incremental dynamical analysis was used to evaluate seismic performance of the structures. Using the results of incremental dynamical analysis, the "capacity of a structure in terms of first mode spectral acceleration", "fragility curve" and "mean annual frequency of exceeding a limit state" was determined. "Mean annual frequency of exceeding a limit state" has been estimated for immediate occupancy (IO) and collapse prevention (CP) limit states using both Probabilistic Seismic Demand Analysis (PSDA) and solution "based on displacement" in the Demand and Capacity Factor Design (DCFD) form. Based on analysis results, the inverted chevron (${\Lambda}$) buckling restrained braced frame has the largest capacity among the considered buckling restrained braces. Moreover, it has the best performance among the considered buckling restrained braces. Also, from fragility curves, it was observed that the fragility probability has increased with the height.

벤더형 모듈을 이용한 광대역 압전 하베스터 연구 (Study of Broadband Piezoelectric Harvester using the Bender-Type Module)

  • 김창일;권태형;여서영;윤지선;정영훈;홍연우;조정호;백종후
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.112-117
    • /
    • 2018
  • In this study, a bender-type piezoelectric energy harvester was fabricated and evaluated to compensate for the disadvantages of high-power generation only in the resonance frequency range of a piezoelectric harvester using a piezoelectric cantilever. The generated power was investigated according to various changes in the vibration environment. Compared with the piezoelectric cantilever module, the bender-type piezoelectric module showed a larger number of peak voltages. The primary peak voltage shifted toward the low frequency when the spring was coupled to the bender-type piezoelectric module. The harvester of the three bender-type modules had a vibration frequency exceeding 1 mW in the 34-45 Hz range and generated 3.112 mW of power at the vibration frequency of 38 Hz. The harvester of the six bender-type modules had a vibration frequency exceeding 1 mW in the 31-45 Hz range and generated 3.081 mW of power at the vibration frequency of 35 Hz.

Microstrip EHF Butler Matrix Design and Realization

  • Neron, Jean-Sebastien;Delisle, Gilles-Y.
    • ETRI Journal
    • /
    • 제27권6호
    • /
    • pp.788-797
    • /
    • 2005
  • This paper describes the design and realization of an extra high frequency band $8{\times}8$ microstrip Butler matrix. Operation at 36 GHz is achieved with a frequency bandwidth exceeding 400 MHz. The circuit is implemented on a bi-layer microstrip structure using conventional manufacturing processes. This planar implementation of a Butler matrix is a key component of a switched beam smart antenna with printed antenna elements integrated on-board. Conception details, simulation results, and measurements are also given for the components (hybrid couplers, cross-couplers, and vertical inter-connections) used to implement the matrix.

  • PDF

현이론을 이용한 사장교 케이블 장력산정 (Estimation of Stay Cable Tension Using String Vibration Theory)

  • 박연수;최선민;이병근;김민중
    • 한국방재학회 논문집
    • /
    • 제9권2호
    • /
    • pp.17-22
    • /
    • 2009
  • 사장교 케이블 장력 산정 방법에는 직접적인 방법과 간접적인 방법이 있는데 직접적인 방법은 정확성에 문제가 있을 뿐만 아니라 제한사항도 많다. 따라서 일반적으로 케이블 장력 추정은 간접적인 방법인 고유진동수를 이용하는 진동법을 사용하고 있다. 최근 시공된 사장교의 케이블에 대해 현이론을 이용한 진동법으로 케이블 장력을 산정해 그 결과를 다중진동모드를 이용한 진동법과 비교했다. 그 결과를 요약하면, 현이론 방법의 오차는 7차이하의 진동모드에서는 2%를 초과하지 않았다. 특히, 3차와 4차 진동모드의 오차는 1%를 초과하지 않았다. 그리고 진동모드의 차수가 증가하고 케이블 단면이 클수록 오차는 증가했고, 장력이 크고 케이블 길이가 길수록 오차는 낮아짐을 알 수 있었다. 즉 7차 이하의 진동모드에서 높은 정밀도를 갖는 다는 것을 알 수 있다.

1990~1995 서울ㆍ수도권 지역의 광화학 오염현상 (Indication of Photochemical Air Pollution in the Greater Seoul Area, 1990 to 1995)

  • 김영성
    • 한국대기환경학회지
    • /
    • 제13권1호
    • /
    • pp.41-49
    • /
    • 1997
  • Status of photochemical air pollution in the Greater Seoul Area (GSA) between 1990 and 1995 was assessed in terms of frequency distributions, number of days exceeding standards, average concentration and meteorological effects. In Seoul compared with other areas in Korea, daily maximum concentration was higher but average concentration was not so high due to lower daily minimum from April to October. The top 5th percentile was high especially in summer season. Average number of days exceeding 100 ppb at monitoring stations in GSA was highest in 1994, the hottest year, but it was only 4 days a year. Mean meteorological pattern of high ozone days could be summarized as low wind speeds, high temperatures, strong solar radiation, and low precipitation. Westerlies were more frequent on high ozone days and at Pangi station located in the eastside of GSA, both number of high ozone days and average concentration were high. Effect of precursor transport on the rise of ozone concentration was, however, not consistently important on the whole in GSA.

  • PDF

FLOODING PSA BY CONSIDERING THE OPERATING EXPERIENCE DATA OF KOREAN PWRs

  • Choi, Sun-Yeong;Yang, Joon-Eon
    • Nuclear Engineering and Technology
    • /
    • 제39권3호
    • /
    • pp.215-220
    • /
    • 2007
  • The existing flooding Probabilistic Safety Analysis(PSA) was updated to reflect the Korean plant specific operating experience data into the flooding frequency to improve the PSA quality. Both the Nuclear Power Experience(NPE) database and the Korea Nuclear Pipe Failure Database(NuPIPE) databases were used in this study, and from these databases, only the Pressurized Water Reactor(PWR) data were used for the flooding frequencies of the flooding areas in the primary auxiliary building. With these databases and a Bayesian method, the flooding frequencies for the flooding areas were estimated. Subsequently, the Core Damage Frequency(CDF) for the flooding PSA of the Ulchin(UCN) unit 3 and 4 plants based on the Korean Standard Nuclear Power Plant(KSNP) internal full-power PSA model was recalculated. The evaluation results showed that sixteen flooding events are potentially significant according to the screening criterion, while there were two flooding events exceeding the screening criterion of the existing UCN 3 and 4 flooding PSA. The result was compared with two kinds of cases: (1) the flooding frequency and CDF from the method of the existing flooding PSA with the PWR and Boiled Water Reactor(BWR) data of the NPE database and the Maximum Likelihood Estimate(MLE) method and (2) the flooding frequency and CDF with the NPE database(PWR and BWR data), NuPIPE database, and a Bayesian method. From the comparison, a difference in CDF results was revealed more clearly between the CDF from this study and case (2) than between case (1) and case (2). That is, the number of flooding events exceeding the screen criterion further increased when only the PWR data were used for the primary auxiliary building than when the Korean specific data were used.

Hidden Markov Chain 모형과 이변량 코플라함수를 이용한 가뭄빈도분석 (Drought Frequency Analysis Using Hidden Markov Chain Model and Bivariate Copula Function)

  • 전시영;김용탁;권현한
    • 한국수자원학회논문집
    • /
    • 제48권12호
    • /
    • pp.969-979
    • /
    • 2015
  • 본 연구에서는 가뭄의 특성분석에 유리하며, 확률론적 접근이 가능한 은닉 마코프 모델(HMM) 기반의 가뭄 분석 기법을 적용하였다. HMM 기반의 가뭄의 심도뿐만 아니라 지속시간을 동시에 평가할 수 있도록 코플라 함수 기반의 이변량 가뭄빈도해석 기법을 도입하여 우리나라의 2015년 가뭄 빈도를 평가하였다. 가뭄빈도분석 결과 최근 40년 자료를 기준으로 영동지방에 비해 영서지방이 전체적으로 가뭄이 발생할 경우 가뭄의 심도가 큰 것으로 평가되었다. 심한가뭄의 발생 비율의 경우에 철원의 경우 10%를 상회하는 등 임진강 유역에서 상대적으로 심한가뭄의 발생비율이 크다는 것을 확인할 수 있었다. 한강유역 일부지점에서는 2014/2015년의 가뭄 지속기간 및 심도의 결합재현기간이 1,000년이 넘는 가뭄이 발생하고 있는 것으로 평가되었다. 특히 북한강 및 임진강 유역에 심한 가뭄이 발생하고 있으며 전반적으로 100년 이상의 기왕최대가뭄을 나타내고 있는 것으로 판단되었다.

Investigation on Terahertz Generation by GaP Ridge Waveguide Based on Cascaded Difference Frequency Generation

  • Li, Zhongyang;Zhong, Kai;Bing, Pibin;Yuan, Sheng;Xu, Degang;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.169-173
    • /
    • 2016
  • Terahertz (THz) generation by a GaP ridge waveguide with a collinear modal phase-matching scheme based on cascaded difference frequency generation (DFG) processes is theoretically analyzed. The cascaded Stokes interaction processes and the cascaded anti-Stokes interaction processes are investigated from coupled wave equations. THz intensities and quantum conversion efficiency are calculated. Compared with non-cascaded DFG processes, THz intensities from 11-order cascaded DFG processes are increased to 5.48. The quantum conversion efficiency of 177.9% in cascaded processes can be realized, exceeding the Manley-Rowe limit.