• Title/Summary/Keyword: frequency delay

Search Result 1,294, Processing Time 0.031 seconds

The Study on development of a SAW SO$_2$ gas sensor (표면탄성파를 이용한 아황산 가스센서 개발에 관한 연구)

  • Lee, Young-Jin;Kim, Hak-Bong;Roh, Yong-Rae;Cho, Hyun-Min;Baik, Sung;,
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 1997
  • A new type SO$_2$ gas sensor with a particular inorganic thin film on SAW devices was developed. The sensor consisted of twin SAW oscillators of the center frequency of 54 MHz fabricated on the LiTaO$_3$ piezoelectric single crystal. One delay line of the sensor was coated with a CdS thin film that selectively adsorbed and desorbed SO$_2$, while the other was uncoated for use as a stable reference. Deposition of the CdS thin film was carried out by the spray pyrolysis method using an ultrasonic nozzle. The sensor could measure the concentration in air less than 0.25 parts per million of SO$_2$. Stability of the sensor turned out to be as good as less than 20ppm, recovery time after each measurement was as short as 5 minutes. Repeatability of the measurement was confirmed through so many reiterated experiments. Hence, the SAW sensor developed through this work showed promising performance as a microsensing tool of SO$_2$. Further work required to improve the performance of the sensor includes enhancement of the reactivity of the CdS thin film with SO$_2$ through appropriate dopant addition, an increase of the center frequency of the SAW device.

  • PDF

DNA Synthesis and Radiosensitivity in Synchronized Human Kidney Cells in Vitro (동화시킨 사람의 신장세포에 있어서의 DNA 합성과 방사선감수성)

  • Kang, Yung-Sun;Park, Sang-Dai;Lee, Chung-Keel
    • The Korean Journal of Zoology
    • /
    • v.14 no.4
    • /
    • pp.175-180
    • /
    • 1971
  • The effects of X-irradiation on the mitotic activity, the chromosome aberration and the DNA synthetic pattern in synchronized human kidney cells treated with 5-AU were measured in the present experiment. When 5-AU was added, mitotic activity was markedly suppressed. After removal of the cells from the chemical, its activity proceeded synchronouly and reached peaks at hours 10. In 5-AU+100R groups, it was observed the X-ray caused mitotic delay, the irregularity of the time when mitotic peak appeared and the inhibiton of mitotic activity. In the control group, chromosome aerrations per cell was 0.030, whereas 0.147 in 5-AU treated group. In 5-AU+100R and 5-AU+200R groups, chromosome aberrations per cell were 0.583 and 0.669 respectively and the average chromosome aberrations per cell per R was 0.0035. 5-AU increased the frequency of labeled metaphases together with labeling intensity, and this is thought to be due to the accumulation of cells by 5-AU at S stage. On the contrary, X-ray decreased the labeling intensity and the frequency of labeled metaphases.

  • PDF

A methodology for Identification of an Air Cavity Underground Using its Natural Poles (물체의 고유 Pole을 이용한 지하 속의 빈 공간 식별 방안)

  • Lee, Woojin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.566-572
    • /
    • 2021
  • A methodology for the identification and coordinates estimation of air cavities under urban ground or sandy soil using its natural poles and natural resonant frequencies is presented. The potential of this methodology was analyzed. Simulation models of PEC (Perfect Electric Conductor)s with various shapes and dimensions were developed using an EM (Electromagnetic) simulator. The Cauchy method was applied to the obtained EM scattering response of various objects from EM simulation models. The natural poles of objects corresponding to its instinct characterization were then extracted. Thus, a library of poles can be generated using their natural poles. The generated library of poles provided the possibility of identifying a target by comparing them with the computed natural poles from a target. The simulation models were made assuming that there is an air cavity under urban ground or sandy soil. The response of the desired target was extracted from the electromagnetic wave scattering data from its simulation model. The coordinates of the target were estimated using the time delay of the impulse response (peak of the impulse response) in the time domain. The MP (Matrix Pencil) method was applied to extract the natural poles of a target. Finally, a 0.2-m-diameter spherical air cavity underground could be estimated by comparing both the pole library of the objects and the calculated natural poles and the natural resonant frequency of the target. The computed location (depth) of a target showed an accuracy of approximately 84 to 93%.

Comparison of the Clinical Performance between Two Pulse Oximeters in NICU: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$ (신생아 중환자실에서 맥박산소측정기의 감지도 비교: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$)

  • Lee, Heun-Ji;Choi, Jang-Hwan;Min, Sung-Ju;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.245-249
    • /
    • 2010
  • Purpose: Numerous false alarms by pulse oximetry, which is widely used in neonatal intensive care unit, can delay response to true alarms. Masimo $SET^{(R)}$ was introduced lately, to overcome false alarms by motion. We compared the clinical performance of two devices (Nellcor $N-595^{(R)}$ and Masimo $SET^{(R)}$) for the evaluation of the false alarm frequency during usual motion artifacts and stable state. Methods: A total of 20 preterm infants weighing 1,000-2,500 g were enrolled in the study. The sensors of two devices were placed on the different feet on the same infants, and both devices were programmed to emit an alarm for episode of hypoxemia (SpO2$\leq$85%). The false alarms were defined as episodes of poor correlation with ECG heart rate, poor waveforms, and the absence of obvious signs of hypoxia. We compared the frequency of false alarms between the two devices. Results: The mean chronological age was 20.8 days and the mean body weight was 1,668 g on the study day. The frequency of total false alarm was significantly fewer for Masimo $SET^{(R)}$ pulse oximetry (48 in Nellcor $N-595^{(R)}$, 27 in Masimo $SET^{(R)}$) although the false alarm during usual motion artifacts was not significantly between two devices (32 in Nellcor $N-595^{(R)}$, 19 in Masimo $SET^{(R)}$). Conclusion: The Masimo $SET^{(R)}$ pulse oximetry has fewer false alarm rates and identified more true hypoxic events than Nellcor $N-595^{(R)}$ pulse oximetry. Therefore, it is useful for adequate oxygen therapy and helps to decrease unnecessary handling by clinicians and nurses.

Risk Factors of Primary Nocturnal Enuresis (일차성 야뇨증의 위험 요인)

  • Lee, Soo-Jin;Yang, Jung-An;Yoo, Eun-Sun;Seo, Jang-Wan;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.69-76
    • /
    • 2000
  • Purpose: The Pathogenesis of primary noctllrnal enuresis(PNE) is still controversial. Genetic factor and maturational delay of micturition reflex including arousal disorder, lack of nocturnal Arginine Vasopressin(AVP) release and functional bladder capacity have been suggested. We analyzed the risk factors of PNE. Methods: Fifty five children with PNE (20 enuretics diagnosed at school physical examination of the first grade students at Mok-Dong Elementary School and 35 enuretics (Age 6-7 year) diagnosed at Ewha Womans University Mok Dong Hospital) and 221 control students without PNE at school physical examination were included. Genetic, stress and developmental factors, arousability, water intake, urine volume, maximun voiding volume and daytime voiding dysfunction were compared. Results: 1) There was no significant difference between PNE and control group in sex ratio, birth order, percentage of working mothers, parental and child personality, age to start walking, school record and duration of sleep. 2) Family history in the PNE group was significantly higher than control group ($20.0\%\;vs\;2.7\%$)(P<0.05). 3) The difficulty in arousal in the PNE group was significantly more common than the control group ($70.9\%\;vs\;54.3\%$)(P<0.05). 4) Nocturnal water intake in the PNE group was significantly greater than the control group ($330{\pm}158.2\;mL\;vs\;235{\pm}129.5\;mL$). Nocturnal urine volume in the PNE group was significantly greater than the control group ( $390{\pm}61.5\;mL\;vs\;140{\pm}43.2\;mL$)(P<0.05). Daily water intake and daily urine volume did not significantly differ between the two groups. 5) Maximum urine volume per void in the PNE group was significantly lower than the control group ($107{\pm}35.9\;mL\;vs\;236{\pm}41.3\;mL$). Daytime voiding dysfunction in the PNE group was significantly more common than the control group ($80.0\%\;vs\;57.9\%$). The voiding frequency in the PNE group was significantly greater than the control group ($7.0{\pm}3.6\;vs\;5.4{\pm}1.6$)(P<0.05). Conclusion: In addition to genetic factors and maturational delay of micturition reflex (difficulty in arousal, nocturnal polyuria and decreased functional bladder capacity) nocturnal polydypsia was found to be the important risk factors fur PNE. So nocturnal fluid restriction should be encouraged as the first-line management of PNE.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Epidermal Condition of Women By Health Promotion Behavior (성인여성의 건강증진 행위에 따른 안면 피부 상태)

  • Lee, Jeong-Ran;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.2 no.2
    • /
    • pp.20-37
    • /
    • 2000
  • The purpose of this study was to investigate the relationships between the differentials in life styles and their effect on the epidermal facial tissue in order to provide a basis for health professionals so that they might better be able to maintain and promote healthy skin care and further delay the premature ageing of the epidermal facial tissue. The subjects consisted of 145 females of various ages who visited skin care room in cerming health promoting behaviors(Park In sook's Profile) and questions on their behavioral practices pertaining to personal skin care were used. The investigation also ess of the four parts of the epidermal facial tissue studied. All data collected wee entered into the SAS program and analyzed for frequency, percentages, the utilized Pusan. The study dates ranged from May 1, 1998 to May 30, 1998. The methods used for this investigation were a questionnaire survey consisting of general objective questions. The questions con a "skin analyzer" to measured levels of moisturizing hydrated, facial oils, and roughnmean, t-test, ANOVA, and Pearson Correlation Coefficients. The results of this study were as follows ; 1. Epidermal facial oil was at its highest levels in the chin area with additional decreasing levels in the forehead and nose regions. The least regions were those of the cheeks. The highest levels of hydration on the other hand started with the forehead followed by the area of the chin, the cheeks and the lowest level of epidermal facial hydration was in the region of the nose. 2. The average score of the performance in the health promoting behaviors variable was 139.51. The variables with the highest degree of the performance were rest and sleeping(35.71). The lowest degree was hiegenic life(23.44). 3. The relationship health promoting behaviors and epidermal condition was not correlated with oil, hydration and roughness of the skin surface. 4. Skin care behavioral characteristics related to epidermal condition were washing style and temperature of washing water. 5. General characteristics related to epidermal condition were occupation, education level, acne and melasma. In conclusion, this study showed that several factors were significant in the behavior of skin care. Clear knowledge of both internal and external factors which affect the epidermal condition will help women to pursue active and appropriate practices in their health behaviors and skin care.

  • PDF

An Agrometeorological Reference Index for Projecting Weather-Related Crop Risk under Climate Change Scenario (농작물의 기상재해 발생위험 판정기준 설정 및 지구 온난화에 따른 기준기상위험의 변화 전망)

  • Kim, Dae-jun;Kim, Jin-hee;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.3
    • /
    • pp.162-169
    • /
    • 2016
  • The agrometeorological reference index means 'the agrometeorological damage possibility' or the possibility of the normal year climate condition to damage the crop cultivation in a certain region. It is a reference used to compare the cultivation risk of a crop by region. The global climate warming is expected to increase the winter temperature. At the same time, the frequency of extreme weather events will also increase. Therefore, people pay attention to the potential of low temperature-induced damages (e.g., frost damage and injury) to fruit trees under the future climate condition. However, simple damage projection based on climate conditions does not help the climate change adaptation in the practical aspect because the climate change affects the phenology of fruit trees as well. This study predicted the phenology of the pear, peach, and apple trees by using the climate change scenarios of major regions. Furthermore, low temperature induced agrometeorological reference indices were calculated based on the effects of temperature on each plant growth stage to predict the damage possibility. It was predicted that the breaking rest would delay more in the future while the bud-burst date and flowering date will be earlier. In Daegu, Jeonju, and Mokpo, the breaking rest delayed more as time passed. The bud-burst date and flowering date of Seoul and Incheon regions were later than other regions. Seoul and Incheon showed a similar pattern, while Daegu and Jeonju revealed a similar pattern. Busan and Mokpo also showed a similar pattern. All regions were safe from the frost damage during the dormancy period. However, plants were vulnerable to frost damage between the breaking rest and the bud-burst period. Regions showed different frost damage patterns between the bud-burst period and the flowering period. During the bud-burst and flowering period, the risk level decreased in general, although the risk of some areas tended to increase.

Measuring Plate Thickness Using Spatial Local Wavenumber Filtering (국소 공간 웨이브넘버 필터링 기법을 이용한 평판 구조물 두께 측정)

  • Kang, To;Lee, Jeong Han;Han, Soon Woo;Park, Jin Ho;Park, Gyuhae;Jeon, Jun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.370-376
    • /
    • 2016
  • Corrosion on the surface of a structure can generate cracks or cause walls to thin. This can lead to fracturing, which can eventually lead to fatalities and property loss. In an effort to prevent this, laser imaging technology has been used over the last ten years to detect thin-plate structure, or relatively thin piping. The most common laser imaging was used to develop a new technology for inspecting and imaging a desired area in order to scan various structures for thin-plate structure and thin piping. However, this method builds images by measuring waves reflected from defects, and subsequently has a considerable time delay of a few milliseconds at each scanning point. In addition, the complexity of the system is high, due to additional required components, such as laser-focusing parts. This paper proposes a laser imaging method with an increased scanning speed, based on excitation and the measurement of standing waves in structures. The wavenumber of standing waves changes at sections with a geometrical discontinuity, such as thickness. Therefore, it is possible to detect defects in a structure by generating standing waves with a single frequency and scanning the waves at each point by with the laser scanning system. The proposed technique is demonstrated on a wall-thinned plate with a linear thickness variation.

The Evaluation of Lower Extremity Muscles in Combat shoes Custom Foot Orthotics (전투화 맟춤형 발보장구 착용 시 하지 근육 활동의 평가)

  • Suh, Sung-Hyeok;Kim, Ro-Bin;Cho, Young-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to examine the effects of customized foot orthotics on lower extremity muscle activity and fatigue during march in combat boots. Four volunteers with normal foot and five volunteers with excessive pronation foot among soldiers on service were fitted with foot orthotics. The electromyography signal from activity of low extremity muscles were collected with surface electromyography device during walking on the treadmill. The walk on the treadmill was performed with a speed of 4.5 km/h. The experiment design for reseach wes composed two experimentation. The first experiment was to examine the muscle activity of lower extremity between normal foot and excessive pronator foot during march. The second experiment was to examine the muscle activity of lower extremity between wearing orthotics and no wearing orthotics. These data were analyzed by the averaged integral EMG and the mean power frequency. The analyzed results were compared by independent T-test method and paired T-test method of SPSS(windows version 12.0). The result of the study were the muscle activity on pronator foot tend to increase during march but a statistically significant increase in muscle fatigue of vastus lateralis and fibularis longus. A statistically significant decrease in muscle activity of anterior tibialis and fibularis longus and fatigue occurred using the customized foot orthotics in volunteers with excessive pronation foot compared to volunteers with normal foot. Clinically, the application of orthotics for the soldiers with excessive pronation foot appears to delay muscle fatigue and prevent from variable foot injuries. This may contribute to enhancing fighting efficiency.