• Title/Summary/Keyword: fr-closed

Search Result 23, Processing Time 0.028 seconds

Some Fuzzy Continuous Mappings and Fuzzy Mildly Normal Spaces

  • Ahn, Y. S.;Choi, K. H.;Hur, K.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.3
    • /
    • pp.280-285
    • /
    • 2001
  • We introduce the new concepts of some fuzzy continuous and closed mappings and study their properties. Also we investigate the properties of fuzzy mildly normal spaces.

  • PDF

Efficacy of 12 Fr. Closed Thoracostomy Drainage in Management of Primary Spontaneous Pneumothorax (12 Fr. 흉관삽입술을 이용한 원발성 자연기흉의 치료)

  • 박상현;지현근;김응중;김건일;박종운;신윤철
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.983-986
    • /
    • 2004
  • Background: The indications of closed thoracostomy drainage in management of primary spontaneous pneumothorax is well known, but there is no special specification for the size to be inserted. Recently, various minimally invasive operational techniques have been introduced and researched. According to the trend, we tried to ascertain the efficacy of 12 Fr. chest tubes instead of the existing 24 Fr. chest tubes. Material and Method: Patients who were younger than 30 years old and diagnosed as primary spontaneous pneumothorax and treated with closed thoracostomy drainage were enrolled in this study. We retrospectively compared group A who were drained with 24 Fr. chest tubes from January to May 2003 with group B with 12 Fr. chest tubes from November 2003 to April 2004 on procedure time for closed thoracostomy drainage, duration of chest tube drain, duration of hospital stay, complication, and recurrence. Result: The male to female ratio was 16 : 3 in group A and 18 : 2 in group B. The mean age of patients of group A was 21.7$\pm$4.0 and group B was 20.0$\pm$3.7. The mean procedure time for closed thoracostomy drainage in group A (21.6$\pm$2.9 minutes) was significantly longer than group B (10.8$\pm$1.9 minutes)(p < 0.05). The mean duration of chest tube drain was 3.8$\pm$ 1.7 days in group A and 4.3$\pm$2.2 in group B, and the mean duration of hospital stay was 5.6$\pm$1.9 days in group A and 5.2$\pm$1.5 days in group B. There was no complication in both groups and 6 cases in group A (35%) and 5 cases in group B (25%) were operated because of recurrence and persistent air leakage. In conclusion, there was no statistical difference except for the procedure time for closed thoracostomy drainage between two groups. Conclusion: We concluded that there were no significant differences in efficacy between 12 Fr. chest tube and 24 Fr. chest tube in closed thoracostomy drainage for primary spontaneous pneumothorax and we found advantages of 12 Fr. chest tube in shortening procedure time because of easy and simple techniques.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • 윤헌주;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

ON SPACES IN WHICH COMPACT-LIKE SETS ARE CLOSED, AND RELATED SPACES

  • Hong, Woo-Chorl
    • Communications of the Korean Mathematical Society
    • /
    • v.22 no.2
    • /
    • pp.297-303
    • /
    • 2007
  • In this paper, we study on C-closed spaces, SC-closed spaces and related spaces. We show that a sequentially compact SC-closed space is sequential and as corollaries obtain that a sequentially compact space with unique sequential limits is sequential if and only if it is C-closed [7, 1.19 Proposition] and every sequentially compact SC-closed space is C-closed. We also show that a countably compact WAP and C-closed space is sequential and obtain that a countably compact (or compact or sequentially compact) WAP-space with unique sequential limits is sequential if and only if it is C-closed as a corollary. Finally we prove that a weakly discretely generated AP-space is C-closed. We then obtain that every countably compact (or compact or sequentially compact) weakly discretely generated AP-space is $Fr\acute{e}chet$-Urysohn with unique sequential limits, for weakly discretely generated AP-spaces, unique sequential limits ${\equiv}KC{\equiv}C-closed{\equiv}SC-closed$, and every continuous surjective function from a countably compact (or compact or sequentially compact) space onto a weakly discretely generated AP-space is closed as corollaries.

A NOTE ON SPACES WHICH HAVE COUNTABLE TIGHTNESS

  • Hong, Woo-Chorl
    • Communications of the Korean Mathematical Society
    • /
    • v.26 no.2
    • /
    • pp.297-304
    • /
    • 2011
  • In this paper, we introduce closure operators [${\cdot}$]c and [${\cdot}$]a on a space and study some relations among [${\cdot}$]c, [${\cdot}$]a and countable tightness. We introduce the concepts of a strongly sequentially closed set and a strongly sequentially open set and show that a space X has countable tightness if and only if every strongly sequentially closed set is closed if and only if every strongly sequentially open set is open. Finally we find a generalization of the weak Fr$\'{e}$chet-Urysohn property which is equivalent to countable tightness.

Relationship between Fraction of Cd in Paddy Soils near Closed Mine and Cd in Polished Rice Cultivated on the same Fields (광산인근 논토양의 카드뮴 존재형태와 쌀의 카드뮴의 함량과의 관계)

  • Kim, Won-Il;Park, Byung-Jun;Park, Sang-Won;Kim, Jin-Kyoung;Kwon, Oh-Kyung;Jung, Goo-Bok;Lee, Jong-Keun;Kim, Jeong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.3
    • /
    • pp.184-189
    • /
    • 2008
  • To assess the relationship between Cd fraction in paddy soils and Cd in polished rice, soils and rice were analyzed at the 3 Cd contaminated paddy fields near closed mines. Major Cd fractions of A field were organically bound (62.6%) and Fe-Mn oxide bound (25.3%) forms. In case of B field, major Cd fractions of B1 field were carbonate bound (46.3%) and Fe-Mn oxide bound (31.6%) form whereas B2 field were residual (54.3%) and carbonate bound (21.8%) form, respectively. It showed a huge difference of Cd fraction each other. 0.1M HCl extractable Cd in soil was positively correlated with Cd in rice. Specially, the ratios of 0.1M HCl extractable Cd against total Cd content in soils were 13.7%, 2.6%, and 0.45% in A, B1, and B2 fields, respectively. These ratio were largely affected with Cd uptake to rice grain. Also, exchangable, Fe-Mn oxide bound, and carbonate bound form, which are partially bioavailable Cd fraction to the plant, were positively correlated with Cd in rice while organically bound and residual form was not correlated. Multiple regression equation was developed with Rice Cd = -0.02861 + 0.07456 FR 1(exchangeable) + 0.00252 FR 2(carbonate bound) + 0.001075 FR 3(Fe Mn oxide bound) - 0.00095 FR 4(organically bound) - 0.00348 FR 5(residual) ($R^2=0.7893^{***}$) considering Cd fraction in soils.

Comparison of the Effect of the Fascial Distortion Model, Foam Rolling and Self-Stretching on the Ankle Dorsiflexion Range of Motion

  • Park, Seol;Kim, Ji-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.4
    • /
    • pp.238-244
    • /
    • 2020
  • Purpose: This study compared the effects of the fascial distortion model (FDM), foam rolling (FR), and self-stretching (SS) on the ankle dorsiflexion range of motion (ROM). Methods: Thirty subjects who had no more than 30° of ankle dorsiflexion ROM at the weight-bearing lunge test were recruited in this study. They were divided into three groups: (FDM, FR, and SS), and underwent each intervention for five minutes. Before and after the intervention, the ankle dorsiflexion ROM in the supine (the open-) and standing (the closed-kinetic chain) of the subjects were tested. The changes in the ROM between pre- and post-intervention and among the groups were analyzed. Results: All groups showed increased ankle dorsiflexion ROM after the intervention in both positions. In the position of the open kinetic chain, the changes in the ROM between pre- and post-intervention had significant differences among the groups, and the FDM was higher than the FR and SS. In the position of the closed kinetic chain, the ROM after the interventions and the changes in the ROM had significant differences among the groups, and FDM was higher than the FR (ROM after the intervention, the change in ROM) and SS (the change in ROM). Conclusion: These findings showed that FDM had more efficiency than the FR and SS as FDM had a stronger effect on increasing ankle dorsiflexion in a short, limited time. Clinicians who have limited time to treat their patients, particularly trying to increase ankle dorsiflexion ROM, should consider the application of FDM.

Comparison of Nutrient Replenishing Effect under Different Mixing Methods in a Closed-loop Soilless Culture using Solar Radiation-based Irrigation (적산 일사 제어법으로 관수하는 순환식 수경재배에서 배액 혼합 방식에 의한 재사용 양액 내 양분 조정효과 비교)

  • Ahn, Tae-In;Shin, Jong-Hwa;Noh, Eun-Hee;Son, Jung-Eek
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.247-252
    • /
    • 2011
  • Electrical conductivity, drainage, and irrigation amount of nutrient solution are important factors for determination of the mixing ratio of fresh and reused nutrient solutions in closed-loop soilless culture. Generally a fixed mixing ratio is applied in commercial scale greenhouses using solar radiation-based irrigation system. Although it ensures continuous supply of fresh nutrient solution in the mixing process, occasional discharge of the drainage is inevitably required. This study was conducted to compare the nutrient replenishing effect under different mixing processes and to investigate appropriate mixing process. For this experiment, a fixed mixing ratio (FR), modifiable mixing ratio (MR), and open-loop (OP) as control were applied. Mixing ratio was determined by a set value of EC for dilution of collected drainage in FR and the set values of 1.0 and $2.0dS{\cdot}m^{-1}$ were used as treatments (FR 1.0 and FR 2.0), respectively. In MR, mixing ratio was determined based on EC and volume of drainage within irrigation volume per event. The volume of drainage stored in the drainage tank tended to increase in FR 1.0. Although such trend was not observed in FR 2.0 and MR, the volume of drainage stored in MR was lower than that in FR 2.0. The ion balance of $Mg^{2+}:K^+:Ca^{2+}$ or $SO^{2-}_4:NO^-_3:PO^{3-}_4$ in the drainage and reused nutrient solution changed within a narrow range regardless of treatment.

SOME NECESSARY AND SUFFICIENT CONDITIONS FOR A FRÉCHET-URYSOHN SPACE TO BE SEQUENTIALLY COMPACT

  • Hong, Woo-Chorl
    • Communications of the Korean Mathematical Society
    • /
    • v.24 no.1
    • /
    • pp.145-152
    • /
    • 2009
  • In this paper, we introduce a new property of a topological space which is weaker than sequential compactness and give some necessary and sufficient conditions for a $Fr{\acute{e}}chet$-Urysohn space with the property to be sequentially compact.