• 제목/요약/키워드: four operation

검색결과 2,254건 처리시간 0.026초

4-레벨 하이브리드 하프 브리지 플라잉 캐패시터 인버터의 새로운 토폴로지 (A New Topology of Four-Level Hybrid Half-Bridge Flying-Capacitor Inverter)

  • 프리바디조나단;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.315-316
    • /
    • 2019
  • This paper proposes the operation scheme and control method for a four-level hybrid half-bridge flying-capacitor inverter (4L-HHBFCI). With in-phase disposition level-shifted modulation (IPD), the flying capacitor voltage ripple is less than 1% of the reference value, while the line-to-line voltage total harmonic distortion is 23.27% at unity modulation index. The performance and effectiveness of the proposed inverter operation have been verified by simulation results.

  • PDF

인공와우 이식 시기에 따른 모음의 음향음성학적 특성 (Acoustic Characteristics of Some Vowels Produced by the CI Children of Various Age Groups)

  • 김고은;고도흥
    • 음성과학
    • /
    • 제14권4호
    • /
    • pp.203-212
    • /
    • 2007
  • This study was to compare some acoustic characteristics of vowels produced by children with cochlear implant (CI) and the children with normal hearing. 20 subjects under ten years old were further classified into two groups (one group of CI children under four years old and the other group of CI children over four years old). For the normal hearing group, 20 subjects are participated in the experiment. Some acoustic parameters including fundamental frequency (F0) and formant frequencies (F1, F2) were measured in the two groups according to the age of cochlear implant operation. For the CI group, three comer vowels (/a/, /i/, /u/) were recorded five times in isolation and analyzed with Multi-Speech (Kay Elemetrics, model 3700), and two independent t-tests on their formant data were conducted using SPSS 11.5. The result showed that the implanted group over four years had a significant difference in F0 and F1 comparing with the implanted group under four years of age as well as the normal hearing group. Those values of the children with the implanted group under four years old were closer to those of the children with the normal hearing. As to the F2, there was no significant difference among implanted groups. However, it was shown that the vowel space for the implanted groups regardless the operation age indicated much smaller than that for the normal hearing children. This acoustic results suggest that CI surgery would be much more effective if it is done under the age of four years old.

  • PDF

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

일정한 토크 평균치를 가지는 유도전동기 직접토크제어기법 (Direct Torque Control Method of Induction Machine with Constant Average Torque)

  • 김정옥;조내수;최병태;김우현;임성운;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.31-34
    • /
    • 2003
  • There are several types of switching table for selection voltage vector in direct torque control of induction motor. In general, two-quadrant and four-quadrant operation switching table are used mostly. Two-quadrant operation has an advantage that reduced the torque ripples in comparison with four-quadrant operation, but it has the defect that is not constant average torque. Because the torque increasing slope size by non-zero voltage vector is different from the torque decreasing slope size by zero voltage vector as speed region. The main objective of this study is to maintain constant average torque using two-quadrant operation switching table. In proposed method, the torque increasing slope or decreasing slope are calculated before selected voltage vector is applied. Then, it is applied to zero voltage vector or non-zero voltage vector until the torque increasing slope and decreasing slope are equal. In total magnitude. Therefore it becomes to maintain average torque at whole operation speed. The validity of the proposed method is proven by simulated and experimental results.

  • PDF

온실가스배출 감소와 연료절감을 위한 최적 운용절차 방안에 관한 연구 (A Study of Optimized Operation for CO2 Emission and Aircraft Fuel Reduced Operation Procedures)

  • 황정현;이태광;황사식
    • 한국항공운항학회지
    • /
    • 제21권4호
    • /
    • pp.62-70
    • /
    • 2013
  • As the aviation industry looks to the future, fuel saving and $CO_2$ emission reduction play a dominant role in meeting the business challenges presented by global financial uncertainty. The IATA and International Government effort to save fuels, and then save 4 billion gallons of fuel burned, while reducing $CO_2$ emissions by 34 million tons. The various reduction methods adapted airlines and airports. We focused on optimized flight operation procedures for saving fuel and reduction emission cases. IATA and Canada government research reports focused on four methods that Engine Core Washing, Portable Water Management, Single Engine Taxi, APU limit operation. Apply to domestic airlines fuel data, Engine Core washing was saving more than Twenty-four thousand tons $CO_2$ emissions.

열병합발전시스템의 단기운전계획을 위한 수리적 모델 수립에 고나한 연구 (A Numerical Modelling of Cogeneration Systems for the Short-Term Operation Strategy)

  • 류승헌;이종범;김준현
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.721-729
    • /
    • 1994
  • In this paper an optimization of the industrial congeneration system which have a thermal storage tank is proposed for the short-term operation strategy. Short-term operation costs of topping cycle and bottoming cycle are calculated by using the proosed model of a thermal storage tank. Simulation result of four cases are compared and analyzed each other.By these simulations which are similar to real operation circumstances. the validity of the proposed model is verified.

시스템의 신뢰성(信賴性) 보증방법(保證方法)에 대(對)한 연구(硏究) (A Study on the Methods of Systems Reliability Assurance)

  • 이상용
    • 품질경영학회지
    • /
    • 제10권2호
    • /
    • pp.2-9
    • /
    • 1982
  • In principle the methods of increasing the reliability of complex system can be classified into the following four basic methods: (1) using the stand-by redundancy; (2) decreasing the failure rate of the system; (3) decreasing the time of continuous operation; (4) decreasing the mean repair time. Among the above four methods, it is generally known that the method of stand-by redundancy is the most effective general, to increase the reliability of systems. Therefor this paper aims to compare the gain in reliability which is achieved by applying stand-by redundancy with other methods, and to show the characteristics of each method From the comparison of the methods of increasing reliability, the following important facts are found: When the method of stand-by redundancy is used to increase the reliability of complex systems intended for long-term operation, a hight multiplicity of stand-by redundancy is required. Thus an increase of the reliability of complex system by applying stand-by redandancy is realized at the expense of characteristics such as weight, size, cost, increased complexity of operation conditions. And this property restricts its use in systems which are critical with respect to weight, size, cost or operation conditions. The method of stand-by redundancy is the most effective when this method is used to increase the reliability of complex systems intended for short-term operation, and the method of decreasing failure rate is the most effective when it is used to increase the reliability of systems intended for long-term use. The methods of increasing reliability discussed in this paper make it possible to make highly reliable systems. But it is not possible to make a highly reliable system using a single method of increasing reliability, even if it is the most effective one. Therefore it is recommended to use all or a majority of the above four methods by choosing it in accordance with the properties of the system under construction.

  • PDF

원발성 심장종양에 대한 외과적 치험 (Surgical Treatment of Primary Cardiac Tumor)

  • 차경태
    • Journal of Chest Surgery
    • /
    • 제24권7호
    • /
    • pp.701-711
    • /
    • 1991
  • We experienced 6 cases of primary cardiac tumor, all received operation for removal of tumor. Mean age was 43.8 years-old ranging from 17 years-old to 66 years-old. Five cases were female, one case was male. Five cases were benign, myxoma, all located within left atrium. One case was malignant, angiosarcoma within right atrium. All patient showed cardiac manifestations. One case was in NYHA functional class II, two were in III, three were in IV. Four patients showed constitutional symptoms, but no one showed evidence of embolic phenomenon. All case of myxoma showed cardiomegaly except one malignancy. Only one case was regular sinus rhythm, three were sinus tachycardia 8z two were atrial fibrillation. The most common site of tumor origin was fossa ovalis limbus[four of all]. Two of five myxomas received emergency operation, one patient died postoperatively. Lived four patients showed no evidence of recurrence[mean follow-up, 3,5 years], but one patient has Grade II /IV mitral regurgitation & in OPD follow-up now, One malignant case, 17 years-old cerebral palsy female, was angiosarcoma occupied most of right atrial chamber originated from anterior wall of right atrium, received emergency operation which was removal of mass & reconstruction of right atrium with artificial pericardial patch. This patient died on postoperative 36th day due to persistent LCOS[low cardiac output syndrome] with combined sepsis.

  • PDF

Transdural Nerve Rootlet Entrapment in the Intervertebral Disc Space through Minimal Dural Tear : Report of 4 Cases

  • Choi, Jeong Hoon;Kim, Jin-Sung;Jang, Jee-Soo;Lee, Dong Yeob
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권1호
    • /
    • pp.52-56
    • /
    • 2013
  • Four patients underwent lumbar surgery. In all four patients, the dura was minimally torn during the operation. However, none exhibited signs of postoperative cerebrospinal fluid leakage. In each case, a few days after the operation, the patient suddenly experienced severe recurring pain in the leg. Repeat magnetic resonance imaging showed transdural nerve rootlets entrapped in the intervertebral disc space. On exploration, ventral dural tears and transdural nerve rootlet entrapment were confirmed. Midline durotomy, herniated rootlet repositioning, and ventral dural tear repair were performed, and patients' symptoms improved after rootlet repositioning. Even with minimal dural tearing, nerve rootlets may become entrapped, resulting in severe recurring symptoms. Therefore, the dural tear must be identified and repaired during the first operation.

초등 수학에서 자연수와 분수의 사칙연산에 대한 개념 익히기 및 연산 사이의 연결 분석 (An Analysis of Mastering Concept and Connection with Operations in Natural Number and Fraction in Elementary School Mathematics)

  • 노은환;정상태;김민정
    • 한국초등수학교육학회지
    • /
    • 제19권4호
    • /
    • pp.563-588
    • /
    • 2015
  • 초등학교에서는 여러 가지 이유로 교수학적 변환이 불가피하다. 수학에서는 덧셈과 곱셈은 이항연산, 뺄셈과 나눗셈은 단항연산으로 다루고 있는 반면, 초등에서는 사칙연산 모두를 이항연산으로 취급하는 교수학적 변환을 시도한다. 그런데 사칙연산의 개념을 '익힌다는 것'은 개념이 어떻게 도입되는가가 더 중요하게 부각된다는 점에서 개념을 이해하는 것과는 다르다. 이에 본 연구에서는 자연수와 분수의 사칙연산을 개념 익히기(개념이 어떻게 도입되고 있는지와 연산 선택의 문제)와 연산 사이의 연결이라는 두 가지 관점으로 분석하여, 자연수와 분수의 사칙연산 지도와 관련된 몇 가지 시사점을 도출하였다. 분수의 나눗셈에서는 상황을 바탕으로 연산을 선택하지 않고 곧장 분수의 곱셈과의 연결을 시도했다는 것과 분수의 나눗셈을 그 자체로 이해하기 위해서는 5학년 2학기와 6학년 1학기에 걸쳐 제시되어 있는 분수의 나눗셈을 통합해야 한다는 것 등이 그것들이다. 이는 후속 교과서 개발 시 유용한 참고자료가 될 것으로 판단된다.