• 제목/요약/키워드: fouling model

검색결과 87건 처리시간 0.024초

Happel Cell 모델을 이용한 막오염 지수 예측 (Prediction of Membrane Fouling Index by Using Happel Cell Model)

  • 박찬혁;김하나;홍승관
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.632-638
    • /
    • 2005
  • Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI) is an important parameter in design of the integrated RO/NF membrane processes for drinking water treatment. In this study, the effect of particle, membrane and feed water characteristics on membrane fouling index were investigated systematically. Higher fouling index values were observed when filtering suspensions with smaller particle size and higher feed particle concentration. Larger membrane resistance due to smaller pore size resulted in an increased membrane fouling index. The variations of feed water hardness and TDS concentrations did not show any impact on fouling index, suggesting that there were no significant colloidal interactions among particles and thus the porosity of particle cake layer accumulated on the membrane surface could be assumed to be 0.36 according to random packing density. Based on the experimental observations, fundamental membrane fouling index model was developed using Happel Cell. The effect of primary model parameters including particle size ($a_p$), particle concentration ($C_o$), membrane resistance ($R_m$), were accurately assessed without any fitting parameters, and the prediction of membrane fouling index such as MFI exhibited very good agreement with the experimental results.

열전달 촉진관내의 화울링 해석-2차원 리브붙이관에 Kern-Seaton 화울링 모델 적용 (Fouling in Enhanced Tubes-Extension of Kern-Seaton Fouling Model to Repeated Ribbed Tubes)

  • 김내현
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.289-298
    • /
    • 1992
  • Fouling is "a major unsolved" area in heat transfer research. Currently, fouling researches are performed in every directions-fundamental aspects, modeling and cumulating experimental data. In this study, an attempt was made to extend the knowledge in enhanced tube fouling. The Kern-Seaton fouling model which was originally proposed for smooth tube fouling was extended to repeated rib tubes. Key parameters-mass transfer coefficient and wall shear stress-were modeled for repeated rib tubes. Some critical points related with the enhanced tube fouling-uncertainties in the mass transfer rate, wall shear stress modeling, deformation of roughness shape during fouling-were discussed, and some quantitative evaluations were made.

  • PDF

열교환기 모델내 하천수와 시수의 Fouling 특성 비교 (A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model)

  • 성순경;서상호;노형운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

정유량 막여과 파울링 모델을 이용한 막여과 정수 플랜트 공정 진단 기법 (A process diagnosis method for membrane water treatment plant using a constant flux membrane fouling model)

  • 김수한
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.139-146
    • /
    • 2013
  • A process diagnosis method for membrane water treatment plant was developed using a constant flux membrane fouling model. This diagnosis method can be applied to a real-field membrane-based water treatment plant as an early alarming system for membrane fouling. The constant flux membrane fouling model was based on the simplest equation form to describe change in trans-membrane pressure (TMP) during the filtration cycle from a literature. The model was verified using a pilot-scale microfiltraton (MF) plant with two commercial MF membrane modules (72 m2 of membrane area). The predicted TMP data were produced using the model, where the modeling parameters were obtained by the least square method using the early plant data and modeling equations. The diagnosis was carried out by comparing the predicted TMP data (as baseline) and real plant data. As a result of the case study, the diagnsis method worked pretty well to predict the early points where fouling started to occur.

Membrane fouling in thermophilic membrane bioreactor with different sludge retention times

  • Ince, Elif;Ince, Mahir;Topaloglu, Alikemal
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.343-351
    • /
    • 2018
  • As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention time increases, membrane fouling rate decreases.

해석적 방법을 통한 압축기의 파울링 해석 (Prediction of Compressor Fouling Using an Analytic Method)

  • 송태원;김동섭;김재환;노승탁
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.176-183
    • /
    • 2000
  • The performance of gas turbines decreases as their operating hours increase. Compressor fouling is the main reason for this time-dependent performance degradation. Airborne particles adhere to the blade surface and results in the change in the blade shape. It is difficult to exactly analyze the mechanism of the compressor fouling because the growing process of the fouling is very slow and the dimension of the fouled depth is very small compared with blade dimensions. In this study, an analytic method to predict the motion of particles and their deposition inside axial flow compressors is proposed. The analytic model takes into account the blade shape and the flow within the blade passage. Comparison of simulation result with field data shows the feasibility of the model. Influence of the particle distribution on the compressor fouling is also examined.

  • PDF

Fouling behaviours of two stages microalgae/membrane filtration system applied to palm oil mill effluent treatment

  • Teow, Yeit Haan;Wong, Zhong Huo;Takriff, Mohd Sobri;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.373-383
    • /
    • 2018
  • Fouling by solids and microorganisms is the major obstacle limiting the efficient use of membrane wastewater treatment. In our previous study, two stages microalgae/membrane filtration system was proposed to treat anaerobic digested palm oil mill effluent (AnPOME). This two stages microalgae/membrane filtration system had showed great potential for the treatment of AnPOME with high removal of COD, $NH_3-N$, $PO_4{^{3-}}$, TSS, turbidity, and colour. However, fouling behavior of the membrane in this two stages microalgae/membrane filtration system was still unknown. In this study, empirical models that describe permeate flux decline for dead-end filtration (pore blocking - complete, intermediate, and standard; and cake layer formation) presented by Hermia were used to fit the experimental results in identifying the fouling mechanism under different experimental conditions. Both centrifuged and non-centrifuged samples were taken from the medium with 3 days RT intervals, from day 0 to day 12 to study their influence on fouling mechanisms described by Hermia for ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) filtration mode. Besides, a more detailed study on the use of resistance-in-series model for deadend filtration was done to investigate the fouling mechanisms involved in membrane filtration of AnPOME collected after microalgae treatment. The results showed that fouling of UF and NF membrane was mainly caused by cake layer formation and it was also supported by the analysis for resistance-in-series model. Whereas, fouling of RO membrane was dominated by concentration polarization.

해수전처리를 위한 침지식 정밀여과 멤브레인 시스템에서 Alginate 파울링의 이해 (Understanding Alginate Fouling in Submerged Microfiltration Membrane System for Seawater Pretreatment)

  • 장호석;권대은;김정환
    • 멤브레인
    • /
    • 제26권1호
    • /
    • pp.55-61
    • /
    • 2016
  • 저압 침지식 멤브레인을 이용한 해수 담수화 전처리에 있어서 유기 파울링은 막간 압력 증가로 인한 화학 세정 횟수의 증가 및 에너지 소비 증가 등 멤브레인 운전시 문제점들을 야기한다. 조류대응 해수전처리에서 조류가 배출하는 extracellular polymeric substances의 대표물질인 sodium alginate를 이용하여 침지식 여과에서 파울링 현상을 관찰하였다. 공기 폭기가 적용되지 않은 경우 순수한 aglinate 파울링은 농도가 증가하면서 증가하였다. 그러나 공기 폭기를 적용해 준 경우 alginate 파울링 감소는 매우 효과적이었다. 공기 폭기가 없는 경우 칼슘 농도의 증가에 따라 alginate 파울링은 감소하였다. 동일 조건에서 공기 폭기 시 높은 alginate 파울링 감소효과를 나타내었으나 NaCl 농도를 증가시킨 경우 칼슘 농도의 증가에 따라 파울링 제어를 위한 공기 폭기 효과는 감소하였다. 해수와 유사한 높은 NaCl과 칼슘 농도에서 고농도 sodium alginate의 경우 공기 폭기량 증가를 통해 초기 파울링을 감소시킬 수 있었으나 시간의 경과에 따라 상대적으로 낮은 폭기량에서의 파울링 감소 효과와 큰 차이는 없었다.

Investigation of Al-hydroxide Precipitate Fouling on the Nanofiltration Membrane System with Coagulation Pretreatment: Effect of Inorganic Compound, Organic Compound, and Their Combination

  • Choi, Yang-Hun;Kweon, Ji-Hyang
    • Environmental Engineering Research
    • /
    • 제16권3호
    • /
    • pp.149-157
    • /
    • 2011
  • Nanofiltration (NF) experiments were conducted to investigate fouling of Al-hydroxide precipitate and the influence of organic compound, inorganic compound, and their combination, i.e., multiple foulants. $CaCl_2$ and $MgSO_4$ were employed as surrogates of inorganic compounds while humic acid was used as surrogate of organic compound. The flux attained from NF experiments was fitted with the mathematical fouling model to evaluate the potential fouling mechanisms. Al-hydroxide fouling with a cake formation mechanism had little effect on the NF membrane fouling regardless of the Al concentration. The NF fouling by Al-hydroxide precipitate was deteriorated in presence of inorganic matter. The effect of Mg was more critical in increasing the fouling than Ca. This is because the Mg ions enhanced the resistances of the cake layer accumulated by the Al-hydroxide precipitate on the membrane surfaces. However, the fouling with Mg was dramatically mitigated by adding humic acid. It is interesting to observe that the removal of the conductivity was enhanced to 61.2% in presence of Mg and humic acid from 30.9% with Al-hydroxide alone. The influence of dissolved matter (i.e., colloids) was more negative than particulate matter on the NF fouling for Al-hydroxide precipitate in presence of inorganic and organic matter.

망간과 휴믹산에 의한 세라믹 막 오염의 제어를 위한 약품 스팀세정의 적용 (Chemically enhanced steam cleaning for the control of ceramic membrane fouling caused by manganese and humic acid)

  • 안선아;박철규;이진산;김한승
    • 상하수도학회지
    • /
    • 제35권6호
    • /
    • pp.425-436
    • /
    • 2021
  • In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, R c/R f increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.