• Title/Summary/Keyword: follow target mode

검색결과 10건 처리시간 0.054초

Application of a Dynamic Positioning System to a Maritime Autonomous Surface Ship (MASS)

  • Kim, Jeong-Min;Park, Hye Ri
    • 한국항해항만학회지
    • /
    • 제46권5호
    • /
    • pp.435-440
    • /
    • 2022
  • The development and introduction of a Maritime Autonomous Surface Ship (MASS) are some of the most important changes leading to the fourth industrial era in the maritime area. The term 'MASS' refers to a ship operating independently, without human intervention, to reduce maritime accidents caused by human errors. Recent UK findings MASS also noted that particularly the dynamic positioning system will be considered to apply as newly function to a MASS. The DP system, a ship system developed decades ago and used for specific purposes like offshore operations, provides various functions to facilitate the accurate movements of the vessel, and operators can make decisions within the DP system, in addition to the ordinary ship system. In this paper, it would like to present the connection and application method with the main technical elements of the DP system in connection with the main technology of the DP system to achieve the safe operation of a MASS. In particular, among various position reference systems, the capability plot function of DP system, and the "follow target" mode in the operation mode are attractive functions that can contribute to the safe operation of autonomous ships.

영상과 GPS 정보를 결합한 Follow-me Selfie 드론 (Visual-GPS combined Drone Follow-me Selfie Drone)

  • 도 딴 뚜안;안희준
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2017년도 추계학술발표대회
    • /
    • pp.134-137
    • /
    • 2017
  • Follow-me function of drones is new and attractive for selfie drone users, where the drone autonomously follows and capture the user. Currently the products use the difference between GPS's in the drone and user side mobile GCS, but the targeting accuracy is not satisfactory owing to the low accuracy of GPS data, often the order of ten meters. We designed a new follow-me mode algorithm that utilizes the accuracy of visual tracking algorithm and the reliability of GPS-based. The experiment shows that proposed follow-me can capture much accurately the target user in the center of video content than GPS-only methods, and recover the vision algorithm failure quickly in 5-10 seconds.

고차 시스템을 위한 근궤적을 따르는 시변 슬라이딩 모드 (Time-Varying Sliding Mode Following Root Locus for Higher-Order Systems)

  • 김가규;최봉열
    • 제어로봇시스템학회논문지
    • /
    • 제5권4호
    • /
    • pp.379-384
    • /
    • 1999
  • In this paper, we present a new time-varying sliding surface to achieve fast and robust tracking of higher-order uncertain systems. The surface passes through an initial error, and afterwards, it moves towards a predetermined target surface by means of a variable named by sliding surface gain and its intercept. Specifically, the sliding surface gain is determined so that its initial value can minimize a shifting distance of the surface and that the system roots in sliding mode can follow certain stable trajectories. The designed sliding mode control forces the system errors to stay always on the proposed surface from the beginning. By this means, the system remains insensitive to system uncertainties and disturbances for the whole time. To illustrate the effectiveness of the proposed method, the comparative study with conventional time-invariant sliding mode control is performed.

  • PDF

감도해석 및 순차적 선형계획법을 이용한 HDD 서스펜션의 형상 최적화 (Opimization of HDD Suspension Shape Using Sensitivity Analysis and Sequential Linear Programing)

  • 황창호;김동욱;이종수;박영필;박노철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.128-133
    • /
    • 2002
  • The main obstacle to high track density in HDD is the structural resonances of the suspension. The most critical mode is sway mode and second torsion mode, when a data is read and written. It is common fact that the effect of two modes is smaller when a thickness is bulky. But the stiffness of suspension is smaller, the slider can follow a disk better. Because these two fact are reciprocal, a compromise is needed. So we investigated another method to improve band width without changing of the thickness of suspension but with changing of the shape. In this paper, we use two method - Sensitivity analysis and SIP using ADS. And we obtained the optimized value close to target value.

  • PDF

입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프 (A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.149-158
    • /
    • 1996
  • 목적 : 선형가속기의 광자선을 이용한 두개내 소병변의 방사선수술에서 다중회전조사와 횡다중회전조사를 병용한 방사선 수술방법을 개발하고, 컴퓨터단층영상을 재구성한 방사선수술계획을 통해 선량분포를 비교하여 병변이외 정상조직의 선량을 줄이기 위한 선량변수를 구하였다. 대상 및 방법 : 선형가속기 6 MV 광자선을 이용하여 치료대 각과 선원지지체 회전 및 환자체위변위를 이용한 입체적 다중 및 횡다중회전조사를 조사하여 선량분포를 비교하였다. 입체적 선량분포와 횡단면, 시상면 및 관상면 치료대 영상재구성의 선량분포는 본 대학에서 개발한 방사선수술기구 및 소프트웨어 (Photon Knife)를 통해 이루어졌다. 입체적 다중회전조사에 의해 얻은 선량은 치료대 각이 20, 50, 120, 160 도, 각각의 선원지지체 회전각은 20-160도이며, 다중회전조사의 치료대각 30, 150도와 횡다중회전조사의 치료대각 30, 150도에 선원 회전각 20-160도를 입체조사하여 비교하였다. 결과 : 선형가속기를 이용한 방사선수술선량분포는 동일 콜리메이터에서도 치료대와 선원지지체 각에 따라 크게 변하였다. 입체횡다중회전조사를 시행한 경우 표적을 중심으로 전후방향의 선량분포는 다중회전조사만을 사용한 경우보다 선량기울기가 증가하여 정상뇌조직의 손상을 더 감소시킬 수 있음을 알 수 있었으며, 병변주위의 치명장기 위치에 따라 방사선 회전 방향을 적절히 정할 수 있다. 방사선수술의 입체선량과 주위 장기 및 표적의 On-Target 입체화는 방사선수술의 정확성, 복수개의 표적중심결정과 주위정상장기의 선량포함범위를 비교적 정확하게 보여줌을 알 수 있다. 결론 : 방사선수술선량계획의 입체화는 선량과 표적 및 주위장기의 선량범위를 입체적으로 정할 뿐만 아니라, 표적의 모양이 불규칙형일 때는 복수개의 표적중심결정에 필수적임을 알 수 있었다. 다중회전조사와 횡다중회전조사를 병합한 방사선수술은 표적주위의 치명정상장기의 손상을 줄이기 위해 총회전각의 변화없이 치명장기에 도달될 선량을 줄일 수 있으며, 25 mm 직경의 콜리메이터를 사용한 선량분포는 $80-50\%$의 간격이 $1.1\~3.0 mm$, $90\~50\%$$2.0\~3.0mm$를 나타내었다.

  • PDF

DEEP-South: 2nd phase of observations for small Solar System bodies

  • Kim, Myung-Jin;Choi, Young-Jun;Yang, Hongu;Lee, Hee-Jae;Kim, Dong-Heun;JeongAhn, Youngmin;Roh, Dong-Goo;Moon, Hong-Kyu;Chang, Chan-Kao;Durech, Josef;Broz, Miroslav;Hanus, Josef;Masiero, Joseph;Mainzer, Amy;Bauer, James
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.46.1-46.1
    • /
    • 2020
  • DEEP-South (DEep Ecliptic Patrol of the Southern Sky) team will start the 2nd phase of KMTNet observation in Oct 2020. The DEEP-South observation mainly consists of three survey modes: (1) Activity survey (AS) that aims at finding active phenomena of small Solar System bodies. (2) Light curve survey (LS) targets to discover and characterize light variations of asteroids. And (3) Deep drilling survey (DS) focuses on the objects beyond the orbit of Jupiter (Centaurus and trans-Neptunian objects) as well as near Earth asteroids. For asteroid family (AF) studies and target of opportunity (TO) observations for urgent photometric follow-up, targeted mode will also be used. DEEP-South team is awarded 7.0% of the telescope time at each site every year from Oct 2020 to Sep 2023 in the 2nd phase of KMTNet operation which corresponds to about 75 full nights a year for the network. In this presentation, we will introduce our survey strategy and observation plan.

  • PDF

식품중 발기부전 치료제 및 유사물질 함량에 관한 조사연구 (A Study on Contents of Anti-impotence drug/drug-like compounds in Food)

  • 홍해근;방선재;박광희;이인숙;박민정;박정화;김종찬
    • 환경위생공학
    • /
    • 제22권3호
    • /
    • pp.89-96
    • /
    • 2007
  • To determine 8 anti-impotence drug/drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil, aminotadalafil, pseudovardenafil and hongdenafil in foods, simultaneously, high performance liquid chromatography(HPLC) and liquid chromatography-mass spectrometry (LC/MS) were used. The HPLC/UV analysis was performed on a column of capcellpak $C_{18}$ with 0.1% sodium-1-hexansulfonate in 0.2M ammonium formate/acetonitrile as a mobile phase. Mass spectra of the compounds by LC/MS were investigated with SCAN mode(Mass range and Fragment voltage) and SIM(Selected Ion Monitoring) mode (Ion target and Fragment voltage). The results follow as; 1. The HPLC/UV analysis was detected from 5 out of 63 samples. The content of sildenafil was in the range of 32.80 ppm ${\sim}$ 60.13 ppm from 4 out of 5 samples. The contents of sildenafil, vardenafil, homosildenafil were in the range 47.14 ppm from 1 out of 5 samples. 2. The conformed result of LC/MS was equal of detected from 5 out of 63 samples in HPLC/UV analysis. An easily available, simultaneous determination of 8 standards in adulterated health related foods was established by using a combination of LC/MS methods.

가솔린 차량의 차대동력계 표준모드 별 추종성 분석 및 배출가스 특성에 관한 연구 (A Study on the the Follow-up Analysis and the Characteristics of Exhaust Gas by Standard Mode of Chassis Dynamometer of Gasoline)

  • 서동춘;박성영
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구에서는 배출가스 및 연비시험에서 드라이브 품질을 평가하기 위해서 가솔린 시험차량 1대를 선정하여 측정하고, 그 측정결과와 제작사가 제시한 값과 비교하여 허용오차 범위(연비-5%, 온실가스+5%, 이하 "허용오차범위")를 초과하는지 평가하였다. 측정결과의 평균값이 제시한 값과 유효한지 데이터를 분석하였다. 본 연구에서는 SAE J2951 평가방법을 기반으로 시험자간의 주행모드 추종성을 가지고 허용오차범위에 대한 데이터 확보를 위해 시험을 수행하였다. 시험차량은 2L급 가솔린차량을 선정하였다. 검증결과 주행 추종성은 고의적인 주행조건에서 전체 값이 커지고, 부드러운 주행조건 일 때, 값이 줄어드는 것을 확인하였다. 주행 추종성 분석결과 수치가 1에 가까울수록 정확하게 주행한 것이며, (-) 음의방향으로 분포하고 있는 가혹조건과 (+) 양의방향으로 분포하고 있는 완만한 조건이라 할 수 있다. 본 연구에서 수행된 시험의 분석을 시험자간 드라이브 추종성에 대한 기초 데이터를 확보하였고, 이러한 기초 데이터는 연비모드의 목표 속도 허용범위 내에서의 운전추종성에 대한 연비 상관성을 분석하였고, 향후 측정결과는 연비측정 모드별 배출가스 DB 확보 및 연비제도에 중요한 기초 자료로 활용될 것으로 사료된다.

사장교 케이블장력 계측장치의 현장적용성 분석 (Field Application Analysis of Cable Tension Measuring Device on Cable-Stayed Bridges)

  • 이현철
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.295-311
    • /
    • 2021
  • 본 연구에서는 사장교 케이블에 대한 장력계측장치의 현장적용성에 대한 실험을 수행하였다. 사장교 케이블의 장력을 추정하기 위해서 진동법을 이용하였으며 대상교량에 대해서 케이블의 가진을 통해서 모드특성을 분석하였고 케이블의 장력을 추정하기 위한 계측장치로는 GTDL360, NI Module, 9 Axes Motion Sensor등을 적용하였고 5개의 대상교량에 대해서 상기 계측장치들을 이용하여 케이블의 모드특성을 분석하여 케이블장력측정실험의 적정성을 평가하고 케이블의 장력을 추정하였다. 또한 5개의 대상교량에 대해서 수치해석을 실시하여 케이블의 고유진동수 및 케이블장력을 해석하였다. 현장 계측결과에 의한 케이블의 추정장력과 수치해석에 의한 케이블의 추정장력을 비교하여 현장계측방법의 적정성을 판단하였으며 분석결과 현장 계측에 의한 케이블의 계측장력과 해석에 의한 추정장력은 오차범위내에 있어서 상기 계측장치들을 현장에 적용하여도 무방할 것으로 판단된다. 현장실증교량의 가속도 기반의 케이블 추정장력과 수치해석에 의한 해석장력과의 값을 비교분석한 결과 값이 허용범위 내로 가속도 기반의 케이블 추정장력값은 적정한 것으로 판단된다. 또한, 현장적용성 분석결과 센서의 설치위치 및 기상조건의 제한 등 계측장치의 한계점이 존재하므로 추후 케이블 스마트 장력계측시스템에 관한 지속적인 후속연구가 필요할 것으로 판단된다.

PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가 (Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D)

  • 박선명;홍건철;이혁;김기;최춘기;석재동
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.111-114
    • /
    • 2010
  • 양전자 방출 단층촬영은 세포의 생화학적 변화에 따른 방사성의약품의 집적 정도를 영상화함으로서 암을 조기에 진단할 수 있는 검사방법으로 알려져 있다. 이러한 집적 정도는 여러 가지 원인에 따라 발생될 수 있는 것으로 $^{18}F$-FDG 주사량, 종양의 크기, 혈중 포도당 농도 등이 있다. 본 연구에서는 집적방사능과 2D와 3D 영상 획득이 방사능 농도(kBq/mL)에 미치는 영향에 대하여 평가하고자 한다. GE Discovery STe 16 PET/CT에서 1994 NEMA PET phantom을 이용하였으며, 배후방사능과 열소의 방사능 농도비가 1:2, 1:4, 1:8, 1:10, 1:20, 1:30 표준이 되도록 하여 2D와 3D로 영상을 획득하였다. 재구성 방법으로 2D와 3D 모두에서 반복연산법으로 반복횟수 2회, 부분집합 20을 적용하였다. 그리고 CT 감쇠보정법과 획득 시간은 10분으로 설정하였다. 또한 영상분석은 열소의 중심과 배후방사능에 동일한 관심영역을 설정 한 후 각 부분의 방사능 농도를 측정하여 비교 분석하였다. 설정된 관심영역의 배후방사능과 열소의 방사능 농도 비는 2D에서 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, 1:26.90, 3D는 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, 1:23.24 값을 얻었다. 또한 표준 방사능 농도비를 기준으로 한 백분율 차이(% Difference)는 2D에서 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, 11.06%로 최소 3.47%에서 최대 11.06% 차이가 있고 3D는 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, 22.69%로 최소 3.66%에서 최대 23.92%까지의 차이를 나타냈다. 방사능 농도가 증가할수록 실제 집적된 방사능 농도의 차이가 커짐을 알 수 있으며, 2D가 3D보다 평균 약 10.6% 높게 집적되어 방사능 농도 변화에 영향을 적게 받는 것으로 나타났다. 따라서 임상환자의 추적 검사에서 영상 획득 방법을 변화할 시 정확한 정량 평가를 위해서 이점을 고려하여 적용하여야 한다.

  • PDF