Abstract
In this study, an experiment was carried out on the field applicability of tension measuring devices of the cables in cable-stayed bridges. The vibration method was used to estimate the tension of cables of cable-stayed bridge, and the mode characteristics of the cable were analyzed using a cable tension measuring device. GTDL360, NI Module, and 9 Axes Motion Sensorwere applied to estimate the cable tension of five target bridges. Numerical analysis of the five target bridges was conducted to analyze the natural frequency of the cable and cable tension. The estimated tension of the cable based on field measurements and estimated tension of cable by numerical analysis were compared with the estimated tension of the cable based on field measurements. The analysis showed that the measured tension of the cable based on field measurements was within the margin of error. Therefore, it is safe to apply these measuring devices to the site. As a result of comparing and analyzing the values of the acceleration-based cable estimation tension and numerical analysis of the field demonstration bridge, the acceleration-based cable estimation of tension is deemed appropriate within the allowable range. On-site applicability analysis revealed limitations of the measuring devices, such as the installation location of sensors and weather conditions, so continuous follow-up research on smart cable tension measuring systems is expected.
Keywords
Cable Tension; Field Measurement; Numerical Analysis; Cable-Stayed Bridge; 9Axes Motion Sensor;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim, B.H., Park, M.S., Lee, I.K., "Modal Parameter Extraction of Seohae Cable-stayed Bridge : I. Mode Shape", KSCE Journal of Civil and Environmental Engineering Research, Vol.28, No.5A, pp.631-639, 2008. https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200830265652213
2 Seoul City, Han River Bridge Online Safety Maintenance System Report, 2012. http://hbsafety25.eseoul.go.kr/open_content/system/introduce.html
3 Korea Expressway Corporation, Final research report of general program for super long span bridge R&D Project, 2016. https://scienceon.kisti.re.kr/srch/selectPORSrchReport.do?cn=TRKO201700000193
4 Korea Expressway Corporation, Technical Report for Special Bridges(Seo Hae, Young Jong and Bang Hwa Grand Bridges), 1998.
5 Shwarz, B. and Richardson, M., "Modal Parameter estimation from ambient response data", Proceeding of 19th IMAC, 2001. https://www.semanticscholar.org/paper/MODAL-PARAMETER-ESTIMATION-FROM-AMBIENT-RESPONSE-Schwarz-Richardson/56d13c4e127087b272a946a2750b89f33c76ea59#paper-header
6 Chlko, T. J., Haritos, N. and Gershkovich, V., "Non-linear curve fitting for modal analysis", Environmental Software, Vol.11, pp.9-18, 1996. DOI: https://doi.org/10.1016/S0266-9838(96)00016-0   DOI
7 Cornwell, P., Farrar, C. R., Doebling, S. W. and Sohn H., "Environmental Variability of Modal Properties", Experimental Techniques, Vol.23, pp.45-48, 1999. DOI: http://dx.doi.org/10.1111/j.1747-1567.1999.tb01320.x   DOI
8 Elliott, A. S. and Richardson, M. H., "Virtual Experimental Modal Analysis(VEMA)", Proceeding of 16th IMAC, 1998.
9 Ja Geul Yun, Jin Son, Seung-Pi Jang, "A Study on Tension Measurement for Cable-Supported Bridge", Proc. of the KSCE Conf., KSCE, pp.117-120, 1999.
10 T. Shimada, A Study on the Maintenance and Management of the Tension Measurment for the Cable of Bridge, Ph Dissertation, Kobe University, 1995.
11 Korea Expressway Corporation, Development of Monitoring-Based Maintenance System for Cable-Supported Bridges, 2011.
12 H. Zui, T. Shinke and Y. Namita, "Practical Formulas for Estimation of Cable Tension by Vibration Method", ASCE Journal of SE, Vol.122, No.6, pp.651-656, 1996. DOI: http://dx.doi.org/10.1061/(ASCE)0733-9445(1996)122:6(651)   DOI
13 Nam-Sik Kim, Woon Jeong, "Evaluation of Tension Force of Stay Cables Using Vibration Method", Journal of the KSNVE, KSNVE, Vol.12, No.12, pp.956-963, 2002. https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200211922274860   DOI
14 Lee, H.J., "Study on the Efficient Application of Vision-Based Displacement Measurements for the Cable Tension Estimation of Cable-Stayed Bridges", Journal of the Korea Academia-Industrial cooperation Society, Vol.17, No.9, pp.709-717,2016. https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO201631261655438   DOI
15 Jenny Lau, Jeroen Lanslots, Bart Peeters, Herman Van derAuweraer., Automatic modal analysis: reality or myths, 2007. http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.150.236
16 Park, Y.S., Choi, S.M., Lee, B.G., Kim, N.J., "Estimation of Stay Cable Tension Using String Vibration Theory", Journal of the Korea Society of Hazard Mitigation, Vol.9, No.2, pp.17-22, 2009. https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200916762902305
17 Lee, H.C., Kwon, K.M., Moon, C.Y., Jo, Y.H., "Measurement Equipment Development of Stability Evaluation for Joint Slope using Unmaned Aerial Vehicle", TUNNEL & UNDERGROUND SPACE, Vol.28, No.3, pp.193-208, 2018. https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO201820540192141   DOI
18 ABSignal, ModalVIEW - Operating Tutorial Version R2, pp.1-199, 2012. https://www.absignal.com
19 Jeong-In Shin., Damage Detection In Braced Steel Frame using Modal Analysis, 2017. https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=DIKO0014383551