• Title/Summary/Keyword: flux recovery

검색결과 197건 처리시간 0.023초

자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성 (Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권5호
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

감극결선용 자속구속형 전류제한기의 사고주기별 전압전류 특성 (Voltage-Current Characteristics According to Fault Period of Flux-Lock SFCL with subtractive polarity winding)

  • 한태희;황종선;조용선;박형민;남긍현;이나영;최효상;임성훈;정동철;최명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.101-102
    • /
    • 2006
  • We investigated the characteristics of flux-lock type superconducting fault current limiter (SFCL) by the fault cycles. Since the recovery characteristics of a superconducting element in the flux-lock type SFCL were dependent on the winding' direction between two coils, the analysis for the recovery characteristics of this type SFCL together with the current limiting characteristic is necessary to apply it to power system. As the fault cycles was increased from 1 cycle to 5 cycles, the initial limiting current ($I_{ini}$) and quench characteristic were mostly same. As the fault period increases, the recovery time of the superconducting element increases. The consumed energy and recovery characteristics in a superconducting element show the same tendency.

  • PDF

한외여과에 의한 다시마 정미성분 분리에 대한 연구 (Studies on the Separation of Taste Components from Sea Tangle (Laminaria japonica) Extract by Cross Flow Ultrafiltration)

  • 이호봉;이승렬;장영상;신재익
    • 한국식품과학회지
    • /
    • 제24권3호
    • /
    • pp.199-203
    • /
    • 1992
  • 한외여과를 이용하여 다시마 열수추출물로 부터 가용성 저분자량의 정미성분을 회수하는데 필요한 조건을 최적화하기 위해, 분리막 선정 및 온도, 압력, Flow rate의 영향을 고찰하였고 선정된 최적 조건하에서 한외여과와 Diafiltration을 실시하여 투과유량의 flux profile과 정미성분의 회수율을 비교하였다. 분리막은 소수성인 GR 51PP가 친수성인 FS 형태보다 높은 투과유량을 유지하였다. Flow rate의 증가에 따라서 투과유량도 증가하는 경향을 보였으나 3.7 l/min에서 한계값을 나타내었다. 한편, 압력이 높은 경우에는 Steady-state에서 투과유량이 감소하는 경향을 보였고 온도 증가에 따라서는 큰 변화는 없었다. 한외여과와 Diafiltration 실시에 따른 투과유량의 Flux profile과 전체 고형분과 정미성분의 회수율을 조사한 결과 한외여과를 실시한 경우가 비교적 높은 회수율을 보였으나 투과유량은 전반적으로 Diafiltration 보다 낮았다.

  • PDF

Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리 (Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • 제4권2호
    • /
    • pp.177-184
    • /
    • 1989
  • 항생물질 발효액의 균사체 분리에 있어서 Modified regenerated cellulose 막을 이용한 Cross-flow filtration으로 높은 Flux를 얻을 수 있었다. 막분리시 가급적 높은 유속, 높은 온도, 특정 균사체농도(약 20% PMV)에서 높은 Flux를 보여주었으며 Fouling 정도는 균사체 농도가 높을수록 또한 유속이 낮을수록 심각한 것으로 나타났다. 발효액을 농축 분리할 때의 Flux profile은 1단계 Sublayer형성에 의한 급속감소, 2단계 평형, 3단계 Fouling에 의한 급속감소의 세 구간으로 나눌 수 있었으며 Diafiltration의 적용으로 3단계의 Flux 감소 현상을 현저히 완화시킬 수 있었다. 한편 Diafiltration에 의한 항생물질 회수시 초기부터Diafiltration하는 것보다는 특정 PMV까지 농축시킨 후 Diafiltration하는 경우에 작업시간과 여액의 Volume을 최소화 할 수 있었으며 본 실험에서는 98%의 회수율을 얻기 위해서 Di-afiltration을 시작하는 Optimum PMV는 20%였다.

  • PDF

루우프형 2상 유동 열사이폰의 비등열전달 특성에 관한 연구 (A Study on the Characteristics of Boiling Heat Transfer of Two-Phase Loop Thermosyphons)

  • 조동현
    • 수산해양교육연구
    • /
    • 제26권3호
    • /
    • pp.639-646
    • /
    • 2014
  • A heat exchanger using two-phase loop thermosyphons was developed as a waste heat recovery system. An experimental study was carried out on the heat transfer characteristics of two-phase loop thermosyphons heat exchanger and the results from the experiments were used to see the possibility which the two-phase loop thermosyphons could be an alternate solution for waste heat recovery system. In the present work, R134a has been used as the working fluid and the filling rate do working fluid and heat flux have been used as the experimental parameters. The results show that the filling rate of working fluid and heat flux are very important factors for the operation of two-phase loop thermosyphons. The experimental results showed the provisional results as a waste heat recovery system.

세라믹 막여과의 성능향상을 위한 응집 전처리의 적용 (Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration)

  • 강준석;송지영;박서경;정아영;이정준;서인석;채선하;김성수;김한승
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

전압증가에 따른 자속구속형 초전도 한류기의 전류제한 및 회복특성 분석 (Analysis on Fault Current limiting and Recovery Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to Increase of Applied Voltage)

  • 최효상;오금곤;한태희;조용선;최명호;한영희;성태현
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.107-112
    • /
    • 2007
  • 자속구속형 초전도 한류기는 1차 권선과 초전도 소자가 직렬로 연결된 2차 권선을 갖는 변압기로 구성되어 있다. 이 초전도 한류기는 결선방향에 따라 감.가극 결선으로 나누어진다. 1차 권선과 2차 권선의 인덕턴스 비에 따라 자속구속형 초전도 한류기는 사고전류의 제한특성을 제어할 수 있다. 본 논문에서는 인가전압에 따른 자속구속형 초전도 한류기의 전압 전류 특성을 분석하였다. 감 가극 결선된 자속구속형 초전도 한류기의 인가전압을 증가시켰을 때, 초기에 제한되는 전류 및 초전도 소자의 ??치 시간은 증가하였다. 초전도 소자의 회복시간은 인가전압이 증가함에 따라 증가하였다. 그러므로 자속구속형 초전도 한류기의 회복특성은 초전도 소자의 소비전력이 증가하기 때문에 초전도 소자에서 소비되는 에너지에 크게 의존한다는 것을 확인할 수 있었다.

결선방향에 따른 자속구속형 전류제한기의 퀜치 회복 의존도 해석 (Analysis on Quench Recovery Dependence of A Flux-Lock Type SFCL According to the Winding Directions)

  • 정수복;조용선;최명호;최효상
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.113-117
    • /
    • 2008
  • 본 논문에서는 결선방향에 따른 자속구속형 전류제한기의 전류제한 및 회 특성에 대해 분석하였다. 자속구속형 초전도 한류기는 초전도 소자와 직렬로 연결된 2차 권선과 병렬로 연결된 1 2차 권선으로 구성되어 있다. 1 2차 권선의 결선방향에 따른 가극 결선과 가극 결선을 갖는 자속구속형 전류제한기를 저항형 전류제한기와 비교하여 분석하였다. 전류제한 및 회복특성은 1 2차 권선의 결선방향에 의존한다. 가극 결선을 갖는 자속구속형 전류제한기의 퀜치시간은 감극 결선이나 저항형 전류제한기보다 더 빠르다는 것을 확인하였다. 초전도 소자에서 소비되는 에너지는 $W= VIt=I^2Rt$으로 표현할 수 있다. 결선 방향에 따라 초전도 소자에서 소비되는 에너지의 차이는 초전도 소자에서 부담하는 전압의 차이 때문이라는 것을 확인할 수 있었다.

알루미늄 드로스로부터 알루미늄의 회수에 관한 연구 (A Study on the Recovery of Aluminum from Aluminum dross)

  • 김홍진;김용현;이병우;이광학
    • 자원리싸이클링
    • /
    • 제6권1호
    • /
    • pp.5-10
    • /
    • 1997
  • 알루미늄 드로스로부터 알루미늄 회수에 관한 연구를 행하였다. 알루미늄 드로스의 발생량이 가장 많은 중립(1.0~12.0mm)의 드로스를 시료로 하여 $850^{\circ}C$의 용해온도와 용해 2시간에서 염화나트륨과 염화칼륨의 첨가 영향은 40% 첨가시 약 76.9%로 최대 회수율을 얻었으며, 그 이상 첨가는 점성의 증가로 회수율에 별 영향을 미치지 않았다. 한편, 40%의 기본염용제에 NaF, $CaF_2$, $AlF_3$${Na}_{3}{AlF}_{6}$ 첨가시 5%에서 최대 회수율을 나타내었으며, 특히 5%의 빙정석 첨가시 약 83.5%의 최대 회수율을 얻을 수 있었다. 그러나 불화물을 5% 이상 첨가시에는 점성이 증가하여 알루미늄 회수율에 큰 영향을 미치지 않았다.

  • PDF

Membrane Filtration Technology for Drinking Water Treatment & Night Soil Treatment

  • Kato, Yasuhiko
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.155-170
    • /
    • 1998
  • 1. The flux for hydrophilic CA membrane is higher than that for hydrophobic PES membrane at any operating conditions. The difference in bpth fluxes becomes greater as the water recovery is lower. 2. Backwash pressure should be more than twice as high as filtration pressure in order to maintain the higher flux. Backwash frequency is independent of the flux when the UF is operated under the same water recovery. 3. The relatively lower crossflow velocity of around 0.1 m/s would be appropriate because of the lower energy consumption per treated water. 4. The membrane fouling occurring at high turbidity and high concentration of organic compounds in raw water can reduce the flux and increase the removal of the organic compounds. 5. It is confirmed by the pilot plant testing that the UF by using the CA membrane module was well applicable to the drinking water treatment.

  • PDF