• Title/Summary/Keyword: flux data

Search Result 1,553, Processing Time 0.023 seconds

Dependence of Energetic Electron Precipitation on the Geomagnetic Index Kp and Electron Energy

  • Park, Mi-Young;Lee, Dae-Young;Shin, Dae-Kyu;Cho, Jung-Hee;Lee, Eun-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.247-253
    • /
    • 2013
  • It has long been known that the magnetospheric particles can precipitate into the atmosphere of the Earth. In this paper we examine such precipitation of energetic electrons using the data obtained from low-altitude polar orbiting satellite observations. We analyze the precipitating electron flux data for many periods selected from a total of 84 storm events identified for 2001-2012. The analysis includes the dependence of precipitation on the Kp index and the electron energy, for which we use three energies E1 > 30 keV, E2 > 100 keV, E3 > 300 keV. We find that the precipitation is best correlated with Kp after a time delay of < 3 hours. Most importantly, the correlation with Kp is notably tighter for lower energy than for higher energy in the sense that the lower energy precipitation flux increases more rapidly with Kp than does the higher energy precipitation flux. Based on this we suggest that the Kp index reflects excitation of a wave that is responsible for scattering of preferably lower energy electrons. The role of waves of other types should become increasingly important for higher energy, for which we suggest to rely on other indicators than Kp if one can identify such an indicator.

An Application of K-$\varepsilon$ Turbulence Model for Predicting Effect of a Rectanguler Obstacle with Heat Flux in a Solt-Ventilated Enclosure on Air Flow

  • 최홍림;김현태;김우중
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.30-44
    • /
    • 1992
  • A modification of the TEACH-like computer program based on the k-$\varepsilon$ turbulence transport was applied for predicting air mixing patterns and temperature distributions in a rectangular, slot-ventilated enclosure having obstructions ; a rectangular obstacle with heat flux, solid walls separates the passage and the pig pens, and purlins beneath the ceiling. Air flow patterns were calculated for the cases with and without the purlin, extending 300mm beneath the ceiling. Comparisons of prediction data of Randall & Battams(1976) showed air flow pattern predicted well for the case without the purlin. Heat was accumulated at the corner of the left side of the solid wall and the right-upper region of the simulated pigs. However the air distribution pattern was completely different from data for the case with the purlin. The deviation from the observation may be attributed to the difference of the geometric configuation. Exploring the cause of the deviation should be conducted in a further study. Temperature stratification was also observed due to incomplete mixing. The obstruction in the route of the inlet air jet at inlet should be avoided since most of kinetic energy dissipates at the abstacle duet to impingement.

  • PDF

Estimation of the Nuclear Power Peaking Factor Using In-core Sensor Signals

  • Na, Man-Gyun;Jung, Dong-Won;Shin, Sun-Ho;Lee, Ki-Bog;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • The local power density should be estimated accurately to prevent fuel rod melting. The local power density at the hottest part of a hot fuel rod, which is described by the power peaking factor, is more important information than the local power density at any other position in a reactor core. Therefore, in this work, the power peaking factor, which is defined as the highest local power density to the average power density in a reactor core, is estimated by fuzzy neural networks using numerous measured signals of the reactor coolant system. The fuzzy neural networks are trained using a training data set and are verified with another test data set. They are then applied to the first fuel cycle of Yonggwang nuclear power plant unit 3. The estimation accuracy of the power peaking factor is 0.45% based on the relative $2_{\sigma}$ error by using the fuzzy neural networks without the in-core neutron flux sensors signals input. A value of 0.23% is obtained with the in-core neutron flux sensors signals, which is sufficiently accurate for use in local power density monitoring.

Corrections on CH4 Fluxes Measured in a Rice Paddy by Eddy Covariance Method with an Open-path Wavelength Modulation Spectroscopy (개회로 파장 변조 분광법과 에디 공분산 방법으로 논에서 관측된 CH4 플럭스 자료의 보정)

  • Kang, Namgoo;Yun, Juyeol;Talucder, M.S.A.;Moon, Minkyu;Kang, Minseok;Shim, Kyo-Moon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • $CH_4$ is a trace gas and one of the key greenhouse gases, which requires continuous and systematic monitoring. The application of eddy covariance technique for $CH_4$ flux measurement requires a fast-response, laser-based spectroscopy. The eddy covariance measurements have been used to monitor $CO_2$ fluxes and their data processing procedures have been standardized and well documented. However, such processes for $CH_4$ fluxes are still lacking. In this note, we report the first measurement of $CH_4$ flux in a rice paddy by employing the eddy covariance technique with a recently commercialized wavelength modulation spectroscopy. $CH_4$ fluxes were measured for five consecutive days before and after the rice transplanting at the Gimje flux monitoring site in 2012. The commercially available $EddyPro^{TM}$ program was used to process these data, following the KoFlux protocol for data-processing. In this process, we quantified and documented the effects of three key corrections: (1) frequency response correction, (2) air density correction, and (3) spectroscopic correction. The effects of these corrections were different between daytime and nighttime, and their magnitudes were greater with larger $CH_4$ fluxes. Overall, the magnitude of $CH_4$ flux increased on average by 20-25% after the corrections. The National Center for AgroMeteorology (www.ncam.kr) will soon release an updated KoFlux program to public users, which includes the spectroscopic correction and the gap-filling of $CH_4$ flux.

Design and Measurement of SFQ DFFC and Inverter (단자속 양자 DFFC와 Inverter의 설계와 측정)

  • 정구락;홍희송;박종혁;임해용;강준희;한택상
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.17-20
    • /
    • 2003
  • We have designed and measured a SFQ(Single Flux Quantum) DFFC and an Inverter(NOT) for superconducting ALU(Arithmetic Logic Unit) development. To optimize the circuit, we used Julia, XIC, and L meter for circuit simulations and circuit layouts. The Inverter was consisted of a D Flip-Flop, a data input, a clock input and a data output. If a data pulse arrives at the inverter, then the output reads ‘0’ (no output pulse is produced) at the next clock period. If there is no input data pulse, it reads out ‘1’(output pulse is produced). The DFFC was consisted of a D flip-Flop, an Inverter, a Data in, a Clock in and two outputs. If a data pulse arrives at the DFFC circuit, then the output2 reads ‘1’ at the next clock period, otherwise it reads out ‘1’ to output1. Operation of the fabricated chip was performed at the liquid helium temperature and at the frequencies of 1KHz.

  • PDF

Laminar Convective Heat Transfer in Vertical Square Duct with Variational Symmetric Heat Flux (비균일 대칭성 열Flux인 수직 사각 닥트내의 층류조합대류 열전달 효과)

  • 김시영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.18 no.1
    • /
    • pp.47-53
    • /
    • 1982
  • An analysis of convection, in a fully developed laminar steady flow through the vertical square duct under the condition of variational symmetric heat flux, is considered. Finite element solution algorithm by Galerkin's method with triangular elements and linear interpolation polynominals for the temperature and velocity profiles are derived for the vertical square duct. The comparison of temperature distribution due to variational symmetric heat flux in the duct were made with available the other data when the condition of peripheral heat flux were uniform and zero. Numerical values for the dimensionless temperatures and Nusselt numbers at selected Rayleigh numbers and pressure gradient parameters were obtained at a few nodal points for the vertical square ducts and effects of corner in the duct were investigated.

  • PDF

Measurements of Gases Emissions form Agricultural Soils and Their Characteristics with Chamber Technique: Emissions of NO and $N_2O$ (챔버를 이용한 농작지로부터의 기체배출량의 측정과 배출특성연구: 일산화질소(NO)와 아질산가스($N_2O$)의 배출량산정)

  • 김득수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.203-212
    • /
    • 2001
  • During the growing season from June to August, 2000, the soil NO and $N_2$O fluxes were measured to elucidate characteristics of soil nitrogen emissions from different types of intensively managed agricultural soils at outskirts of Kunsan City, located in the western inland of Korea, Flux measurements were made using a closed chamber technique at two different agricultural fields; one was made from upland field, and the other from rice paddy field. The flux data from upland field were collected for both the green onion and soybean field. Concentrations of NO and $N_2$O inside a flux chamber ar 15 minute sampling interval were measured to determine their soil emissions. Either polyethylene syringes of teflon air bags were used for gas samples of $N_2$O and NO. The analysis of NO and $N_2$O was made using a chemiluminesence NO analyzer and GC-ECD, respectively no later than few hours after sample collection at laboratory. The gas fluxes were varied more than one standard deviation around their means. Relatively high soil gas emissions occurred in the aftermoon for both NO and $N_2$O. A sub-peak for $N_2$O emission was observed in the morning period, but not in the case of NO. NO emissions from rice paddy field were much less than those from upland site. It seems that water layer over the rice paddy field prevents gases from escaping from the soil surface covered with were during the irrigation and acts as a sink of these gases. The NO fluxes resulted from these field experiments were compared to those from grass soil and they were found to be much higher. Diurnal and daily variations of NO and $N_2$O emission were discussed and correlated with the effects of nitrogen fertilizer application on the increase of the level of soil nitrogen availability.

  • PDF

APPLICATION OF REMOTE SENSING IMAGERY ON THE ESTIMATE OF EVAPOTRANSPIRATION OVER PADDY FIELD

  • Chang, Tzu-Yin;Chien, Tzu-Chieh;Liou, Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.752-755
    • /
    • 2006
  • Evaportranspiration is an important factor in hydrology cycle. Traditionally, it is measured by using basin or empirical formula with meteorology data, while it does not represent the evaportranspiration over a regional area. With the advent of improved remote sensing technology, it becomes a surface parameter of research interest in the field of remote sensing. Airborne and satellite imagery are utilized in this study. The high resolution airborne images include visible, near infrared, and thermal infrared bands and the satellite images are acquired by MODIS. Surface heat fluxes such as latent heat flux and sensible heat flux are estimate by using airborne and satellite images with surface meteorological measurements. We develop a new method to estimate the evaportranspiration over the rice paddy. The surface heat fluxes are initialized with a surface energy balance concept and iterated for convergent solution with atmospheric correct functions associated with aerodynamic resistance of heat transport. Furthermore, we redistribute the total net energy into sensible heat and latent heat fluxes. The result reveals that radiation and evaporation controlled extremes can be properly decided with both airborne and satellite images. The correlation coefficient of latent heat flux and sensible heat flux with corresponding in situ observations are 0.66 and 0.76, respectively. The relative root mean squared errors (RMSEs) for latent heat flux and sensible heat flux are 97.81 $(W/m^2)$ and 124.33 $(W/m^2)$, respectively. It is also shown that the newly developed retrieval scheme performs well when it is tested by using MODIS date.

  • PDF

Operational Water Temperature Forecast for the Nakdong River Basin Using HSPF Watershed Model (HSPF 유역모델을 이용한 낙동강유역 실시간 수온 예측)

  • Shin, Chang Min;Na, Eun Hye;Kim, Duck Gil;Kim, Kyunghyun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.673-682
    • /
    • 2014
  • A watershed model was constructed using Hydrological Simulation Program Fortran to predict the water temperature at major tributaries of Nakdong River basin, Korea. Water temperature is one of the most fundamental indices used to determine the nature of an aquatic environment. Most processes of an aquatic environment such as saturation level of dissolved oxygen, the decay rate of organic matter, the growth rate of phytoplankton and zooplankton are affected by temperature. The heat flux to major reservoirs and tributaries was analyzed to simulate water temperature accurately using HSPF model. The annual mean heat flux of solar radiation was estimated to $150{\sim}165W/m^2$, longwave radiation to $-48{\sim}-113W/m^2$, evaporative heat loss to $-39{\sim}-115W/m^2$, sensible heat flux to $-13{\sim}-22W/m^2$, precipitation heat flux to $2{\sim}4W/m^2$, bed heat flux to $-24{\sim}22W/m^2$ respectively. The model was calibrated at major reservoir and tributaries for a three-year period (2008 to 2010). The deviation values (Dv) of water temperature ranged from -6.0 to 3.7%, Nash-Sutcliffe efficiency(NSE) of 0.88 to 0.95, root mean square error(RMSE) of $1.7{\sim}2.8^{\circ}C$. The operational water temperature forecasting results presented in this study were in good agreement with measured data and had a similar accuracy with model calibration results.

Improvement of Convection by Pulsatile Blood Pump in High Flux Hemodialysis System (고 유량 혈액 투석 시스템에서 박동류 펌프에 대한 대류 향상에 관한 연구)

  • Choi, D.S.;Um, K.M.;Lee, J.C.;Lee, S.R.;Mun, C.H.;Choi, H.;Min, B.G.;Kim, H.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.376-383
    • /
    • 2008
  • High-flux dialysis treatment removes various toxins via diffusion as well as convection, which is induced by ultrafiltration and backfiltration. In this study, in vitro (Using the distilled water and the bovine's blood) comparison test was performed to determine whether utilization of a high flux dialyzer paired with different pumps would increase the efficiency of convection. At the same blood flow rates, a pulsatile pump and a roller pump were employed to propel the distilled water and bovine whole blood to a high flux dialyzer. Pressures at the dialyzer inlet and outlet in the blood circuit and in the dialysate circuit were measured, respectively. From these data, we calculated the transmembrane pressure and predicted the ultrafiltration and backfiltration rates developed by both pumps. Using the bovine's blood experiment, ultrafiltration and backfiltration rates were 1.6 times higher with the pulsatile pump than with the roller pump. We conclude that utilization of a pulsatile pump in high flux hemodialysis treatments increases ultrafiltration volume, compared with a roller pump under conditions of the same blood flow rate.