• 제목/요약/키워드: flow meter

검색결과 595건 처리시간 0.029초

차압을 이용한 터빈유량계 성능 진단 (Diagnosis on performance of turbine flowmeter using differential pressure in the meter)

  • 하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

오리피스 유량계의 헌팅 원인과 영향인자에 관한 해석적 연구 (The Numerical Analysis about the Hunting Factors of the Orifice Meter)

  • 신창훈;안승희;정종태;허재영;김우식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.150-157
    • /
    • 2005
  • Generally, the flow hunting is observed in almost all of the orifice meters but the intensity of the flow hunting is different at each metering system. So, we were getting some Questions as follows; why such a difference occurs and whether it influence to metering error rate or not. To investigate the flow hunting characteristics, we are trying to examine the flow characteristics around the orifice meter when the transient flow or pressure is generated at after the PCV(Pressure Control Valve) by 3D CFD method. And we have compared numerical results with experimental results at M - PCV station in order to clarify the relations with both the metering-pipeline diameter and flow rate. Finally, we can show some major factors influencing to the flow hunting and propose some correcting scheme of the flow hunting equation.

  • PDF

스플리터 단면형상변화에 따른 플라스틱 유량계의 유동진동특성 (Fluidic oscillation characteristics of plastic flow meter with the variation of cross-sectional shape of splitters)

  • 이성희
    • Design & Manufacturing
    • /
    • 제15권2호
    • /
    • pp.56-62
    • /
    • 2021
  • In this study, design technology of a non-mechanical flow meter using fluidic oscillation generated during the fluid flow in the chamber was investigated. To with respect to design a splitter, which is the most important factor in fluid oscillation, a transient flow simulation analysis was performed for three types of shapes and changes in inlet flow velocity. The oscillation characteristics with respect to the time in each case were compared, and it was confirmed that the SM03 model was the best among the presented models. In addition, the FFT analysis of the fluid oscillation results for the SM03 model was used to obtain a linear correlation between the flow velocity change and the maximum frequency, and a frequency of 20.957 (Hz/m/s) per unit flow velocity was obtained. Finally, injection molding simulation and molding experiment of the chamber with the designed splitter were performed.

유량측정 오차에 미치는 유동조건의 영 향 검출방법 연구 (An Identification Method of the Influence of Flow Conditions on the Flow Metering Error)

  • 이광복;최해만;백종승
    • 설비공학논문집
    • /
    • 제3권1호
    • /
    • pp.34-41
    • /
    • 1991
  • The effect of flow conditions on flow measurement is difficult to identify from the inherent characteristics of the flowmeters and flow standard system. A new experimental approach has been attempted to detect the turbine meter error due to inlet flow conditions. In this try not only the design of the turbine meter package but also the data analysis method was altered. It was found that k factor slope of the turbine meter responds to the change of flow conditions in the test line with higher sensitivity than the degree of the data scattering. The flow standard system of $0.1m^3/s$ was chosen for the investigation. The systematic and random error of the system were less than ${\pm}0.08%$ and ${\pm}0.13%$ respectively.

  • PDF

두 개의 컨덕턴스미터를 이용한 슬러그류의 기공률 및 기공률 전달속력 실시간 측정 (Real-time measurement of void fraction and its propagation speed of slug flow with two Conductance meters)

  • 김종록;안예찬;강덕홍;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1569-1573
    • /
    • 2004
  • Two ring-type conductance meters were manufactured to measure void fraction and its propagation speed in slug flow. The signal of conductance meter with two rings depends on liquid temperature. Therefore a conductance meter with separated probe designed by Coney (1973), which is independent of liquid temperature, was used and experimentally proved. The manufactured conductance meters showed a good repeatability and agreement with the analytical solution by Coney (1973). From time lag between two conductance meter, we could calculate the propagation speed of void fraction.

  • PDF

스크류유량계 개발에 있어서의 역공학 및 성능평가에 관한 연구 (Study on the reverse engineering and performance test in the development of screw flowmeter)

  • 김종윤;황종대;이상열;정윤교
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.132-137
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw type flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flow meter.

  • PDF

Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계 (The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters)

  • 김민철;권기범;임동현;송창석;정용석;장태원;유호대;정만홍
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권5호
    • /
    • pp.1000-1011
    • /
    • 1998
  • 연구배경: 기관지 천식 환자들과 만성폐쇄성폐질환의 진단이나 기도폐쇄 정도를 알기 위하여 통상적으로 노력성 호기곡선이나 최대호기류량곡선을 이용한 환기기능검사가 널리 이용되고 있다. 그러나 외래를 방문하는 환자들이나 자가 치료를 하는 환자들의 경과관찰에는 검사의 간편성으로 인해 peak flow meter를 이용한 peak expiratory flow(PEF)가 많이 이용된다. 이 경우 PEF의 변이성이 크기 때문에 절대값이나 증상이 없을 때의 최대값을 기준으로 비교하여 사용하기도 하는데 검사 판정의 객관성은 추정정상치가 가장 높을 것이다. 그러나 현재까지 국내에서는 최대호기류량곡선을 이용한 PEF(FEFmax)의 추정정상치의 보고는 다수 있으나 peak flow meter를 이용한 보고는 아직까지 없었다. 이에 실제 환자들이 스스로 쉽게 측정할 수 있는 PEF의 추정정상치를 산출하고 이 값이 $FEV_1$을 비롯한 다른 환기기능검사를 어느 정도 정확하게 예측할 수 있는 지를 조사 연구하였다. 방 법: 호흡기 증상이나 기왕 병력이 없는 건강한 남자 129명(나이 ; 19-74 세), 여자 125명(나이 ; 18-67세)을 대상으로 외래에서 mini-Wright peak flow meter(Clement Clarke International Ltd. England)를 이용하여 3 회 이상 PEF를 측정하였다. 아울러 Microspiro HI-501 portable spirometer(Chest Co., Japan)로 노력성호기곡선, 최대호기류량곡선을 측정 분석하여 $FEV_1$, FVC, $FEV_1/FVC$, $FEF_{25-75%}$, $FEF_{25%}$, $FEF_{50%}$, $FEF_{75%}$와 FEFmax를 구하여 각각의 추정정상치를 구하였고 PEF의 $FEV_1$ 및 FEFmax에 대한 설명력을 회귀분석을 통해 구하였다. 결 과: PEF(L/min)의 추정정상치는 남자가 -2.45$\times$Age(year) + 1.36 $\times$ Height(cm) + 427였고 ($R^2=0.28$), 여자에서는 -0.96 $\times$ Age(year) + 2.01 $\times$ Height(cm)+129였다($R^2=0.12$). 최대호기류량곡선에서 산출한 FEFmax는 PEF보다 납자에서는 $125{\pm}74.0$(L/min), 여자에서는 $118{\pm}52.2$(L/min) 적었다. PEF로 예측할 수 있는 $FEV_1$(ml)값은 남자에서 5.98 $\times$ PEF(L/min) + 303 이고 ($R^2=0.43$), 여자에서는 4.61 $\times$ PEF(L/min) +291 이었다($R^2=0.33$). 결 론: 건강한 성인 254명(남자 129명, 여자 125명)을 대상으로 peak flow meter로 측정한 PEF의 추정정상치를 연령과 신장을 변수로 하여 구하였다. 여기서 측정한 PEF로 $FEV_1$ 및 FEFmax를 어느 정도 예측할 수 있었다. 그리고 측정기계 및 방법에 따라서 PEF 값이 달라짐을 확인하였는데 이런 점을 유의한다면 PEF의 측정은 향후 환자 진료에 많은 도움이 될 것으로 생각한다.

  • PDF

천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구 (A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors)

  • 하영철;이철구;장승룡;이강진
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.83-89
    • /
    • 1998
  • 단열이 되어 있지 않은 천연가스 계략배관에서 배관 내$\cdot$외의 온도차로 인한 오리피스 유량계 오차를 정성적으로 실험하였다. 고려된 주요 인자는 유속과 대기온도이며 태양복사열도 일부 고려되었다. 실험결과 유량이 극히 작고, 배관 내$\cdot$외의 온도차가 큰 하절기 유동조건에서도 그다지 큰 오차는 발생하지 않는 것으로 분석되었다.

  • PDF

공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구 (A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders)

  • 김도태
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.