• Title/Summary/Keyword: flow level

Search Result 4,356, Processing Time 0.034 seconds

Numerical Study of Fluidic Device in APR1400 Using Free-Surface Model (자유수면모델을 활용한 APR1400 유량조절장치의 수치해석 연구)

  • Lim, Sang-Gyu;You, Sung-Chang;Kim, Han-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.767-774
    • /
    • 2012
  • A fluidic device (FD) has been adopted in the safety injection tanks (SITs) of APR1400. A flow control mechanism of the FD was used to vary the flow regime in the vortex chamber corresponding to the SITs water level. The flow regime in the vortex chamber has a different pressure loss from low to high in accordance with the SITs water level. Nitrogen at the top of the SIT could be released owing to inertia of discharge flow when changing from a high flow rate to a low flow rate. This phenomenon is important to design improvement perspective because it can affect the performance of the FD. This paper shows a result of a preliminary numerical study to obtain the transient data related to air release in the flow turn-down period using a two-fluid free-surface model provided from ANSYS CFX 13.0. In conclusion, there is no significant effect on the performance of the FD, though a small quantity of air is released during the flow turn-down period.

Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy (경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성)

  • Lim, Jeong-Hwan;Song, Jun-Hyeok;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

Analysis of submerged flow characteristics of the improved-pneumatic-movable weir through the laboratory experiments (개량형 공압식 가동보의 잠김흐름 특성 분석을 위한 실험연구)

  • Lee, Kyung Su;Jang, Chang-Lae;Lee, Namjoo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.615-623
    • /
    • 2016
  • This Study calculated the Submerged Flow Characteristics and Discharge coefficient by the rising angular change of the Improved-Pneumatic-Movable. According to the result, the smaller the ratio of weir height and weir length (L/W) or the weir standing angle, the bigger of the downstream head ($H_2$). The change of discharge reduction factor ($Q_s/Q_1$), by the hight from weir crest to downstream surface and the ratio form weir crest to upstream water height ($h_t/H$), was decreased when the $h_t/H$ closed to number 1. Although the weir water depth of the down-stream was shallower level than the up-stream, the velocity was faster then before. And the more the flow, the less the gab between the upper and lower reaches level. And when the same flow condition, the downstream head ($H_2$) was increased when the L/W was bigger. The Submerged Flow Discharge coefficient of Improved-Pneumatic-Movable weir was made by the upstream approach flow head and the upper lower stream flow condition, not by the physical data of Movable weir.

The Effects of STEAM Program on the Scientific Communication Skills and the Learning Flow of Elementary Gifted Students (STEAM 프로그램이 초등영재학생의 과학적 의사소통능력과 학습몰입에 미치는 영향)

  • Bak, Aerina;Kim, Yong Kwon
    • Journal of Korean Elementary Science Education
    • /
    • v.33 no.3
    • /
    • pp.439-452
    • /
    • 2014
  • The purpose of this study is to find out the effect of STEAM program on the scientific communication skills and the learning flow of elementary gifted students. The main findings of this study are as follows: First, STEAM program that mathematical, technical, engineering and art factors were combined based on basic concepts of science were developed. Seconds, the change in the scientific communication skills of experimental group applying STEAM program had statistically meaningful difference (p<.05). Third, the flow of experimental class improved, but it had no meaningful difference statistically (p>.05). But it is expected that continuing level adjusted STEAM program might have positive effect on improving the flow with the following three reasons: 1) The gifted students' flow level on learning before experiment was rather too high to expect short term effect. 2) It was hard for them to achieve flow experience because topic difficulties and students' capacities were not balanced. 3) topic commitments and autotelic behaviors of gifted students were observed during classes. Fourth, by the result of the student satisfaction questionnaire survey on this program, students actively participated in the STEAM program with interest and curiosity. As achieved self-directed problem solving, versatile communication activities and success experiences, their class satisfaction was high. Based on such results, it was expected that the gifted class applied of STEAM program could enhance scientific communication capacity of the elementary gifted students and would further positively influence flow of learning as well. In addition, it was considered to have integrated approach value to elementary gifted and talented education in the aspect that it could satisfy various educational demands of gifted students.

Flow Field Separating Technique in Bubbly Flow using Discrete Wavelet (이산 웨이블릿을 이용한 Bubbly flow의 유통분리기법)

  • Jo, Hyo-Jae;Doh, Deog-Hee;Choi, Je-Eun;Takei, Masahiro;Kang, Byung-Yoon
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.777-783
    • /
    • 2008
  • Nowadays wavelet transforms are widely used for the analyses of PIV velocity vector fields. This is bemuse the wavelet provides not only spatial information of the velocity vectors but also of time and frequency domains. In this study, a discrete wavelet trC1f1$form has been applied to real PIV images of bubbly flows. The vector fields obtained by a self-made cross-correlation PIV algorithm were used for the discrete wavelet transform The performances of the discrete wavelet transform is investigated by changing the level of power of discretization. The decomposed images by the wavelet multiresolution showed conspicuous characteristics of the bubbly flows according to the level changes. The high spatial bubble concentrated area could be evaluated by the constructed discrete wavelet transform algorithm, at which high leveled wavelets could play a dominant roles to reveal the flow characteristics.

Influence of Learning Presence of Non-Face-to-Face Class Experience in Nursing Students on Academic Achievement: Mediating Effect of Learning Flow and Moderated Mediation of Digital Literacy (비대면 수업 경험 간호대학생의 학습실재감이 학업성취도에 미치는 영향: 학습몰입의 매개효과와 디지털 리터러시의 조절된 매개효과)

  • Ryu, Eui Jeong;Jang, Keum Seong;Kim, Eun A
    • Journal of Korean Academy of Nursing
    • /
    • v.52 no.3
    • /
    • pp.278-290
    • /
    • 2022
  • Purpose: This study aimed to identify the mediating effect of learning flow and the moderated mediation effect of digital literacy on the effect of the learning presence of non-face-to-face class experience in nursing students on academic achievement. Methods: Participants were 272 nursing students from six universities in two different cities. A self-report questionnaire was used to measure learning presence, learning flow, digital literacy, and academic achievement. Analysis was performed using SPSS 26.0 and SPSS PROCESS Macro (4.0). Results: The mediating effect of learning flow on the effect of learning presence on academic achievement was 0.42, and the moderated mediation index of digital literacy was 0.17. Learning flow showed a mediating effect on the relationship between learning presence and academic achievement. Digital literacy had a moderated mediation effect on the relationship between learning presence and academic achievement that was mediated by learning flow. Conclusion: The intensity of the mediating effect of nursing students' learning presence on academic achievement through learning flow increases as the level of digital literacy increases. These results suggest that educational programs considering the level of learning presence, learning flow, and digital literacy are required to promote the academic achievement of nursing college students.

Additional Improvement and Evaluation of Exhaust Ventilation Systems at Small and Medium Sized Enterprise (중.소규모 사업장의 국소배기장치 설치 실태와 문제점 및 개선방안)

  • Lim, Seong-Keun;Park, Doo-Yong;Kim, Won-Ki;Kim, Soo-Geun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Objectives : The purposes of this study were to evaluate exhaust ventilation systems(EVSs) and to suggest problems and improvements. Methods : For 50 small and medium-sized enterprises, we carried out evaluation of EVSs. We evaluated hoods with smoke tester and measurement of capture velocity. In addition, we used several indicators for performance evaluation designed in this study. Results : 1. Based on the smoke flow pattern and the criteria of occupational health and safety act, 67.8% of hoods were rated 'good' level at smoke test whereas 26.3% were rated 'good' level at measurement of capture velocity. 2. 29.3% of hoods, of which ratio of measured actual air flow at hood(Qah) to required ideal exhaust air flow at hood(Qih) was 1 or more, were rated 'good' level. 3. The % of EVS, of which ratio of measured actual air flow at stack(Qast) to total required ideal exhaust air flow at hood(Qith) was 1 or more, was 29.0%. 4. For the ratio of measured Qast to existing air flow at fan(Qfan), only 5% of EVSs were 1 or more and 26.0% were 0.8 or more but less than 1.0. 5. For the ratio of measured Qast to total measured actual exhaust air flow at hood(Qath), 74.0% were 0.8 or more but less than 1.0. 6. The percentage of EVS, of which ratio of total measured Qath to existing Qfan was 0.8 or more, was 19.0%. 7. The percentage of EVS, of which ratio of total measured Qath to total required ideal exhaust Qith was 1 or more, was 26.0%. 8. For the comprehensive evaluation indicators designed in this study, 29.0% were 0.8 or more. Conclusions : We found that few exhaust local ventilations at small and medium-sized enterprises were rated 'good' level and that most exhaust local ventilations had 'poor' design and installation. Therefore, relevant professional manpower and enterprises have to construct exhaust local ventilation where it is needed, and technical guidance and economic support are needed to improve 'poor' exhaust local ventilation after self-evaluation.

A Study on Hydraulic Analysis using GIS-based RMA-2 and HEC-1 - For Stream Reach between Gongdo and Pyeongtaek Water Level Gauge Stations - (GIS 기반의 하천흐름해석모형 RMA-2와 유역유출모형 HEC-1을 이용한 하천의 수리학적 특성 분석 연구 - 공도·평택 수위관측소 구간을 대상으로 -)

  • Park, Min-Ji;Park, Geun-Ae;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.1
    • /
    • pp.124-135
    • /
    • 2007
  • The purpose of this study is to analyze the hydraulic behavior in a stream reach using SMS RMA-2 model with a series of dynamic boundary conditions of main stream and lateral flows simulated by WMS HEC-1 program. For the stream reach (10.5 km) between Gongdo and Pyeongtaek water level gauge stations of Anseongcheon, the model simulated two dimensional flow characteristics by applying dynamic flow conditions of rainfall frequencies of 50, 100, 500, and 1,000 years for the main stream and three tributaries. The temporal flow behavior successfully simulated and the results showed that the distribution of mean velocity and water level within the stream reach increased according to the increase of flow frequency. Especially, the flow velocity sensibly increased at the near downstream of lateral inflow as the width of main stream is narrower.

  • PDF

Level Dynamics and Control of the Solution in the High Temperature Generator of an Absorption Chiller (흡수식 냉온수기 고온재생기 액면 거동과 제어)

  • Shin, Young-Gy;Kwak, Min-Soo;Cho, Hyun-Wook;Nam, Sang-Chul;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.852-858
    • /
    • 2010
  • In an absorption chiller, solution is circulated by a solution pump with an inverter to vary flow rate depending on operating conditions. For optimal operation, the solution level in the high temperature generator should be kept constant. However, a sensor for measuring continuous level is not available because of varying solution concentration. Instead, level switches are used and hence feedforward control associated with limit checking is a common practice. In the study, inverter frequencies are estimated from a dynamic simulation model and pump performance. Designed frequencies are compared with those implemented in real chillers. It was found that the frequencies used in real chillers are larger than those needed in circulation flow rates. It was intended to prevent system shut-off caused by dry-out. However, it is necessary to minimize the excessive frequency setting in order to reduce frequent pump stops and the range of solution level for continuous pump operation.

The Optimal Power Flow Algorithm Considering Load Power Factor Limits (부하역률 제약조건을 고려한 최적 급전 알고리즘)

  • 김광욱;조종만;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.494-499
    • /
    • 2004
  • This paper presents to compute the power economic dispatch, an optimal power flow (OPF) computation algorithm, considering the load power factor limits constraint in developed. Efficient reactive power planning enhances economic operation as well as system security. Accordingly, an adequate level of power factor limits for the load busesshould be evaluated for economic operation. In this paper, the ranges of acceptable load power factors are portrayed as bandwidths of load power factor expressed as a function of load level. The load power factor limits are included and described into the OPF's objective function. The method Proposed is applied to IEEE 26 bus system.