• 제목/요약/키워드: flow control structure

검색결과 570건 처리시간 0.025초

형상기억합금을 이용한 난방용 온도조절 밸브 및 원격 제어장치 개발 (Development of Heat Control Valve Using SMA and Remote Controller for House Heating System)

  • 최정주;염정국
    • 한국기계가공학회지
    • /
    • 제9권2호
    • /
    • pp.6-11
    • /
    • 2010
  • For the purpose of reducing the energy consumption in the house heating, the various devices have been developed. One of these is to control the flow in the heat pipe and the flow control valve using shape memory alloy(SMA) spring is proposed in our study. The proposed house heating system is to save the gas consumption and the remote control system is designed for the convenience of using the proposed valve. The developed valve consists of SMA spring, disk, return spring, and regulation handle. The regulation handle is for supplying the additional hot water and is controlled by remote-control-motor. In order to design the remote control system, the Zigbee wireless communication protocol is used. The performance of the proposed valve structure is shown through the experimental result.

Design of I-PDA Controller Incorporating FFC for Flow Control Systems

  • Cahyadi, A.I.;Khuakoonratt, N.;Benjanarasuth, T.;Ngamwiwit, J.;Komine, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1007-1011
    • /
    • 2003
  • In this paper, a design of I-PDA controller by CDM to control a flow process whose structure is first order lag plus a dead time is introduced. The factor of dead time of the process is approximated by second order Pade approximation in order to get a third order system. The simulations show that both of the transient and steady state specifications can be fulfilled. However, the transient response of the I-PDA control system still has long rise time. Then, a feedforward controller (FFC) with two adjustable parameters and one derivative time is introduced into I-PDA control system for improving the speed of the system response. It is shown, from the simulation results, that the performance of the I-PDA control system with suitable FFC has shorter rise time and no overshoot, while settling time remains almost the same. The performance comparison of the proposed control system with the PI control system with and without FFC is also made.

  • PDF

PIV기법을 이용한 룸에어컨 주변 유동 분포 해석 (Analysis of Flow Distribution around Room Air Conditioner Using PIV Technique)

  • 이아미;한규일;김동원;라선욱;주재만;고한서
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.131-134
    • /
    • 2006
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure by various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan, and the relationship between the control of the eccentric vortex and the inlet and outlet angles has been confirmed in this study.

  • PDF

블레이드 앞전 3차원 형상 변형에 의한 터빈 캐스케이드 내의 이차유동 제어 (Secondary flow Control in the Turbine Cascade with the Three-Dimensional Modification of Blade Leading Edge)

  • 김정래;문영준;정진택
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1552-1558
    • /
    • 2002
  • The blade leading edge is modified to control the secondary flow generated in the turbine cascade with fence by intensifying the suction side branch of the horseshoe vortex. The incompressible Navier-Stokes equations are numerically solved with a high Reynolds number k-$\varepsilon$ turbulence closure model for investigating the vortical flows in the turbine cascade. The computational results of total pressure loss coefficients in the wake region are first compared with experiments for validation. The structure and strength of the passage vortex near the suction surface are examined by testing various geometrical parameters of the turbine blade leading edge.

비선형 슬라이딩 면을 이용한 온수난방 순환펌프 시스템의 온도 제어 (Temperature control for a hot water heating circulating pump system using a nonlinear sliding surface)

  • 안병천;장효환
    • 제어로봇시스템학회논문지
    • /
    • 제3권2호
    • /
    • pp.162-168
    • /
    • 1997
  • Digital variable structure controller(DVSC) is implemented to control the temperature for the hot water heating circulating pump control system. For the DVSC, a control algorithm is suggested, which using a nonlinear sliding surface and a PID sliding surface outside and inside of steady state error boundary layer, respectively. Smith predictor algorithm is used for the compensation of long dead time. The DVSC of the suggested algorithm yields improved control performance compared with the one of existing algorithm. The system responses with the suggested DVSC shows good responses without overshoot and steady state error inspite of heating load change. By decreasing sampling time, dead time and rise time are increasing, and system output noise by flow dynamics is amplified.

  • PDF

실시간 다중고장진단 제어기법에 관한 연구 (A Study on Real time Multiple Fault Diagnosis Control Methods)

  • 배용환;배태용;이석희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.457-462
    • /
    • 1995
  • This paper describes diagnosis strategy of the Flexible Multiple Fault Diagnosis Module for forecasting faults in system and deciding current machine state form sensor information. Most studydeal with diagnosis control stategy about single fault in a system, this studies deal with multiple fault diagnosis. This strategy is consist of diagnosis control module such as backward tracking expert system shell, various neural network, numerical model to predict machine state and communication module for information exchange and cooperate between each model. This models are used to describe structure, function and behavior of subsystem, complex component and total system. Hierarchical structure is very efficient to represent structural, functional and behavioral knowledge. FT(Fault Tree). ST(Symptom Tree), FCD(Fault Consequence Diagrapy), SGM(State Graph Model) and FFM(Functional Flow Model) are used to represent hierachical structure. In this study, IA(Intelligent Agent) concept is introduced to match FT component and event symbol in diagnosed system and to transfer message between each event process. Proposed diagnosis control module is made of IPC(Inter Process Communication) method under UNIX operating system.

  • PDF

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • 제32권5호
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

A Modular Bi-Directional Power Electronic Transformer

  • Gao, Zhigang;Fan, Hui
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.399-413
    • /
    • 2016
  • This paper presents a topology for a modular power electronic transformer (PET) and a control scheme. The proposed PET consists of a cascaded H-Bridge rectifier on the primary side, a high-frequency DC/DC conversion cell in the center, and a cascaded H-Bridge inverter on the secondary side. It is practical to use PETs in power systems to reduce the cost, weight and size. A detailed analysis of the structure is carried out by using equivalent circuit. An algorithm to control the voltages of each capacitor and to maintain the power flow in the PET is established. The merits are analyzed and verified in theory, including the bi-directional power flow, variable voltage/frequency and high power factor on the primary side. The experimental results validated the propose structure and algorithm.

초고층 주상복합구조물에 적용한 고강도 콘크리트의 배합설계 및 품질관리 시스템에 관한 연구 (A Study On the Mix Design and Quality Control System of High Strength Concrete for the Construct ion of High Rise Complex Structure)

  • 김선구;이상수;원철;박상준;김동석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.40-45
    • /
    • 2001
  • The purposes of this study were mix design and quality control of high strength concrete for the construction of high rise complex structure. Desired performances of this high strength concrete were slump flow 50$\pm$10cm, air content 4.5$\pm$1.5% and design strength 400kgf/$cm^2$. Experimental flow was that optimal mix design was selected in the indoor experiment and after that, producing test was done in the batcher plant. Excel lent results of experiment was obtained from binder content 475kg/$m^2$ with replacement ratio 10% of fly ash. The results of field application of high strength concrete was sufficiently satisfied both flowability and compressive strength.

  • PDF

Reformate 분리공정에서의 열복합 증류탑 제어구조에 관한 연구 (Study on Control Efficiency of Thermally Coupled Distillation Column for Reformate Fractionation Process)

  • 이주영
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3774-3778
    • /
    • 2012
  • Reformate 분리 공정에 대한 열복합 증류탑의 가능한 제어 구조를 조사하고 그 제어 성능을 검토하기 위하여 동적 모사를 수행하였다. Aspen HYSYS를 사용하여 $3{\times}3$ 제어구조를 적용하여 여러 가지 제어구조로 동적 모사한 결과 Reformate 분리 공정 주탑의 상부, 중간, 하부 제품 조성은 각각 reflux flow rate, 주탑에서 전처리탑 상부로 흐르는 liquid draw rate, vapor boilup rate로 제어되는 구조가 가장 운전 안정성이 확보됨을 확인하였다.