• 제목/요약/키워드: flow cell

검색결과 3,119건 처리시간 0.034초

Orostachys japonicus DW and EtOH Extracts Induce Apoptosis in Cholangiocarcinoma Cell Line SNU-1079

  • Choi, Eun Sol;Lee, Jang Hoon
    • 대한한의학회지
    • /
    • 제36권4호
    • /
    • pp.19-34
    • /
    • 2015
  • Objectives: This study was performed to investigate the anti-tumor effect of O. japonicus extracts on intrahepatic cholangiocarcinoma cell line SNU-1079. Methods: Cholangiocarcinoma SNU-1079 cells were treated with various concentrations of O. japonicus DW and EtOH extracts ($0-300{\mu}g/ml$) for 24, 48 or 72 h. Cell viability was evaluated through a PMS/MTS assay, and the apoptosis rate was examined through ELISA assay and flow cytometry analysis. The mRNA expression of apoptosis- and cell cycle progression-related genes (Bcl-2, Mcl-1, Bax, Survivin, Cyclin D1, and p21) was evaluated using real-time PCR, and the caspase activity was examined using immunoblot analysis. Results: O. japonicus extracts inhibited cell proliferation and increased apoptosis rate in both ELISA assay and flow cytometry analysis. O. japonicus extracts decreased Bcl-2, Mcl-1, Survivin, and Cyclin D1 mRNA expression and increased Bax mRNA level. O. japonicus extracts also increased Caspase-3 activation. Overall, O. japonicus DW extracts were more effective than EtOH extracts. Conclusions: O. japonicus inhibited cell proliferation and induced apoptosis in SNU-1079 cells via mitochondria -mediated intrinsic pathway, which leads to Caspase-3 activation. The results indicate that O. japonicus is a potential therapeutic herb with anti-tumor effect against intrahepatic cholangiocarcinoma.

3차원 CFD 시뮬레이션을 활용한 고분자전해질 연료전지 스택의 매니폴드 크기 최적화 (Optimal Sizing of the Manifolds in a PEM Fuel Cell Stack using Three-Dimensional CFD Simulations)

  • 정지훈;한인수;신현길
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.386-392
    • /
    • 2013
  • Polymer electrolyte membrane (PEM) fuel cell stacks are constructed by stacking several to hundreds of unit cells depending on their power outputs required. Fuel and oxidant are distributed to each cell of a stack through so-called manifolds during its operation. In designing a stack, if the manifold sizes are too small, the fuel and oxidant would be maldistributed among the cells. On the contrary, the volume of the stack would be too large if the manifolds are oversized. In this study, we present a three-dimensional computational fluid dynamics (CFD) model with a geometrically simplified flow-field to optimize the size of the manifolds of a stack. The flow-field of the stack was simplified as a straight channel filled with porous media to reduce the number of computational meshes required for CFD simulations. Using the CFD model, we determined the size of the oxidant manifold of a 30 kW-class PEM fuel cell stack that comprises 99 cells. The stack with the optimal manifold size showed a quite uniform distribution of the cell voltages across the entire cells.

외부온도가 수송용 메탄올연료전지 성능에 미치는 영향 (Effects of environmental temperature on the performance of direct methanol fuel cell for vehicles)

  • 한창화;최지선;정대승;한상훈;이중희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.176-179
    • /
    • 2009
  • The performance of direct methanol fuel cells is affected by operating conditions such as, methanol feeding temperatures, methanol concentrations, and methanol flow rates during the operation in different environmental conditions. In this study, effects of the environmental temperature on performance of direct methanol fuel cells have been investigated in order to test a applicability of direct methanol fuel cell to the vehicle. The environmental temperature (ET) was varied from $-20^{\circ}C$ to $+30^{\circ}C$. The inside fuel cell temperature (CT) during test at various operating conditions was monitored and the performance of fuel cell was measured in the I-V polarization curve. With increasing the ET, the performance of the fuel cell was significantly improved and the CT also almost linearly increased. However, at below $0^{\circ}C$ ET, the DMFC showed very poor performance and needed to control CT or methanol feeding temperature (MFT), methanol flow rate(MFR) to obtain enough power of the vehicle.

  • PDF

고온 고분자전해질 연료전지 박판형 분리판의 유로 설계 및 스택 성능 평가 (Flow Field Design and Stack Performance Evaluation of the Thin Plate Separator for High Temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김지홍;김민진;김진수
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.442-449
    • /
    • 2018
  • Research on High temperature polymer electrolyte fuel cell (HT-PEMFC) has actively been conducted all over the world. Since the HT-PEMFC can be operated at a high temperature of $120-180^{\circ}C$ using phosphoric acid-doped polybenzimidazole (PBI) electrolyte membrane, it has considerable advantages over conventional PEMFC in terms of operating conditions and system efficiency. However, If the thermal distribution is not uniform in the stack unit, degradation due to local reaction and deterioration of lifetime are difficult to prevent. The thin plate separator reduces the volume of the fuel cell stack and improves heat transfer, consequently, enhancing the cooling effect. In this paper, a large area flow field of thin plate separator for HT-PEMFC is designed and sub-stack is fabricated. We have studied stack performance evaluation under various operating conditions and it has been verified that the proposed design can achieve acceptable stack performance at a wide operating range.

분뇨처리장 방류수정화 갈대습지셀의 초기운영단계 질산성질소 제거 (NO3-N Removal of A Reed Wetland Cell Constructed for Purifying Effluent from A Night Soil Treatment Plant During Its Initial Operating Stage)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제7권5호
    • /
    • pp.100-106
    • /
    • 2004
  • $NO^3$-N removal was examined from July 2002 to December 2002 of a surface-flow constructed treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and one distribution pond. The system was established on rice paddy near the Kohung Estuarine Lake located at the southern part of the Korean Peninsula. The lake and the paddy were formed by a salt marsh reclamation project. Effluent from a secondary-level treatment plant was funneled into the system. The investigated cell was created in June 2002. Its dimensions were 87 m in length and 14 m in width. It had an open water zone at its center, which was equivalent to 10 percent of its total area. Reeds(Phragmites australis) were transplanted from natural wetlands into the cell and their stems were cut at about 40 cm height from their bottom ends. Average 25 $m^3$/day of effluent from the plant was funneled into the cell by gravity flow and average 24.2$m^3$/day of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. The average height of the reed stems was 45.2 cm in July 2002 and 80.5 cm in September 2002. The number of stems averaged 40.3 stems/$m^2$ in July 2002 and 74.5 stems/$m^2$ in September 2002. The reeds were established initially well. $NO_3$-N loading rate of influent and effluent averaged 173.7 and $93.5mg/m2{\cdot}day$, respectively. Removal of $NO_3$-N averaged $80.2mg/m2{\cdot}day$ and its removal rate by mass was about 50 %. Considering the initial operation of the cell and the inclusion of the cold months of November and December in the analysis period, the $NO_3$-N removal rate was good.

Proposed Guidelines for Selection of Methods for Erosion-corrosion testing in Flowing Liquids

  • Matsumura, Masanobu
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.291-296
    • /
    • 2007
  • The corrosion of metals and alloys in flowing liquids can be classified into uniform corrosion and localized corrosion which may be categorized as follows. (1) Localized corrosion of the erosion-corrosion type: the protective oxide layer is assumed to be removed from the metal surface by shear stress or turbulence of the fluid flow. A macro-cell may be defined as a situation in which the bare surface is the macro-anode and the other surface covered with the oxide layer is the macro-cathode. (2) Localized corrosion of the differential flow-velocity corrosion type: at a location of lower fluid velocity, a thin and coarse oxide layer with poor protective qualities may be produced because of an insufficient supply of oxygen. A macro-cell may be defined as a situation in which this surface is the macro-anode and the other surface covered with a dense and stable oxide layer is the macro-cathode. (3) Localized corrosion of the active/passive-cell type: on a metal surface a macro-cell may be defined as a situation in which a part of it is in a passivation state and another in an active dissolution state. This situation may arise from differences in temperature as well as in the supply of the dissolved oxygen. Compared to uniform corrosion, localized corrosion tends to involve a higher wall thinning rate (corrosion rate) due to the macro-cell current as well as to the ratio of the surface area of the macro-anode to that of the macro-cathode, which may be rationalized using potential vs. current density diagrams. The three types of localized corrosion described above can be reproduced in a Jet-in-slit test by changing the flow direction of the test liquid and arranging environmental conditions in an appropriate manner.

디젤탈황 단위공정의 CFD 모델링을 포함한 연료전지 시스템 공정설계 및 최적화 (Process Simulation and Optimization of Fuel Cell System including CFD Modeling of Diesel Desulfurizer Unit Process)

  • 최창용;임도진
    • Korean Chemical Engineering Research
    • /
    • 제56권3호
    • /
    • pp.421-429
    • /
    • 2018
  • 본 연구에서는 100 kW급 연료전지 시스템의 운영을 위한 공정 및 CFD 모델링을 진행하였다. 공정 모델링을 통해 연료전지 각 단위 공정에 유입되는 유량을 도출하였으며 수소로 전환되지 않는 디젤의 환류량을 도출하였다. 디젤의 환류를 고려한 새로운 유입 유량 조건을 이용해 CFD 해석을 진행한 결과, 환류 디젤이 없는 것으로 가정한 이전 연구결과에 비해 더 짧은 유입시간과 비슷한 시간의 처리시간을 가지는 이점이 있음을 확인하였다. 6기의 탈황 반응기를 이용해 100 kW급 연료전지를 가동시키는데 필요한 TSA 탈황 시스템 구성을 완료하였으며 전체 TSA 공정 운영을 위한 운용 방안을 도출하였다. 반응기 사이의 열 전달 해석을 통해 저온의 탈황공정과 고온의 재생공정 간의 열 간섭이 크지 않음을 확인하였다. 본 연구결과는 연료전지 시스템의 효율화에 기여할 것이며, 도출된 탈황모듈의 설계는 연료전지 시스템뿐만 아니라 청정 석유화학산업의 기초가 될 것으로 기대된다.

구강편평세포암종에서 미슬토 추출물의 Apoptosis 유도 효과에 대한 실험적 연구 (AN EXPERIMENTAL STUDY ON MISTLETOE EXTRACT-INDUCED APOPTOSIS IN ORAL SQUAMOUS CELL CARCINOMA)

  • 허균행;이재훈;김철환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권1호
    • /
    • pp.13-23
    • /
    • 2005
  • This study was performed to investigate mistletoe extract-induced apoptosis in oral squamous cell carcinoma. In vivo study, HN22 cells were xenografted in nude mice. After tumor was experimentally induced, mistletoe extract was directly injected on the tumor mass. The specimens were evaluated using light and transmission electron microscopes. In vitro study, HN22 cells were cultured and exposed to mistletoe extract. The cells were evaluated using transmissin electron microscope. To evaluate apoptotic cells, flow cytometric analysis was done. The results were obtained as follows: 1. Light microscopic view of tumor mass showed necrosis at 2-4 weeks. 2. Transmission electron micrographs of tumor mass showed apoptosis and necrosis. 3. In TEM view of cell lines, necrosis and apoptosis were shown with mistletoe extract at $300{\mu}g/ml$, apoptosis was shown with mistletoe extract at $100{\mu}g/ml$. 4. In flow cytometric analysis, early and late apoptosis was shown when using caspase-3Ab and annexin-V, but no significant change was noted when using mebstain and Apo2.7 Ab. In this study, mistletoe extract induced necrosis and apoptosis in the tumor mass was induced by HN22 cells, early and late apoptosis in vitro study. Mistletoe extract was likely to induce cell death in oral squamous cell carcinoma through apoptosis.

2차처리장 방류수 정화 부들습지셀의 초기운영단계 질산성질소 제거 (Nitrate Removal of a Cattail Wetland Cell Purifying Effluent from a Secondary-Level Treatment Plant During Its Initial Operating Stage)

  • 양홍모
    • 한국환경농학회지
    • /
    • 제23권4호
    • /
    • pp.228-233
    • /
    • 2004
  • Nitrate removal was examined from May to October 2003 of a surface flow treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and a distribution pond The system was established on rice paddy near the Kohung Estuarine Lake located in the southern part of the Korean Peninsula. Effluent from a secondary-level night soil treatment plant was funneled into the system. The investigated cell, 87 m in length and 14 m in width, was created in April 2003. An open water was designed at its center, which was equivalent to 10 percent of its total area. Cattails (Typha angustifolia) were transplanted from natural wetlands into the cell and their stems were cut at about 40cm height from their bottom ends. Average $25.0\;m^3/day$ of effluent from the treatment plant was funneled into the cell by gravity flow and average $24.1\;m^3/day$ of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. Average height of the cattail stems was 42.5 cm in May 2M3 and 117.7 cm in September 2003. The number of stems averaged $9.5\;stems/m^2$ in May 2003 and $16.4\;stems/m^2$ in September 2003. The growth of cattails was good. Temperature of influent and effluent averaged 25.9 and $26.7^{\circ}C$, respectively. $NO_3$-N loading rate of influent and effluent averaged 176.67 and $88.09\;mg/m^2\;day$, respectively. Removal of rf03-N averaged $89.58\;mg/m^2\;day$ and its removal rate by mass was about 50%. Considering its initial operating stage in which cattail rhizomes and litter layer on the bottom were not Idly established, the $NO_3$-N removal rate of the cell was rather good.

하이브리드/전기 자동차 배터리 냉각 시스템의 냉각수 유동 특성이 냉각 성능에 미치는 영향에 대한 해석적 연구 (Effect of Coolant Flow Characteristics in Cooling Plates on the Performance of HEV/EV Battery Cooling Systems)

  • 오현종;박성진
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.179-185
    • /
    • 2014
  • Average temperature and temperature uniformity in a battery cell are the important criteria of the thermal management of the battery pack for hybrid electric vehicles and electric vehicles (HEVs and EVs) because high power with large size cell is used for the battery pack. Thus, liquid cooling system is generally applied for the HEV/EV battery pack. The liquid cooling system is made of multiple cooling plates with coolant flow paths. The cooling plates are inserted between the battery cells to reject the heat from batteries to coolant. In this study, the cooling plate with U-shaped coolant flow paths is considered to evaluate the effects of coolant flow condition on the cooling performance of the system. The counter flow and parallel flow set up is compared and the effect of flow rate is evaluated using CFD tool (FLUENT). The number of counter-flows and flow rate are changed and the effect on the cooling performance including average temperature, differential temperature, and standard deviation of temperature are investigated. The results show that the parallel flow has better cooling performance compared with counter flow and it is also found that the coolant flow rate should be chosen with the consideration of trade-off between the cooling performance and pressure drop.