• Title/Summary/Keyword: floor mortar

Search Result 75, Processing Time 0.024 seconds

An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis (시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

Mechanical Properties and Field Implementation of Floor Mortar Incorporated with VAE Polymer (VAE 폴리머를 이용한 모르타르 바닥재의 역학적 특성과 현작 적용성)

  • Bang, Jin-Wook;Lee, Sun-Mok;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.27-34
    • /
    • 2017
  • Recently, the importance of the industrial warehouse floor has been increasing due to the development of the distribution and logistics industry. In this present study, an early-hardening polymer floor mortar which can compensate for the limitation of conventional cement based floor mortar regarding fluidity and long curing time was developed. In order to achieve the early-hardening of mortar characteristic ultra rapid hardening cement was used as binder. Four types of mixture proportions in accordance with the vinyl acetate ethylene(VAE) polymer contents with range from 10% to 20% and the other proto proportion without VAE polymer were designed. Mechanical experiments including the fluidity test, compressive strength test, bending test, bond test, and abrasion test were conducted for all mixture proportions. From the flow test result, it was possible to achieve the high flow with 250 mm by controlling the amount of superplasticizer. The incorporation of VAE polymer was found to affect the compressive strength reduction, however, the flexural strength was higher than that of the proto mixture, and it was evaluated to increase the compressive strength / flexural strength ratio. Moreover, at least 2.6 times higher bond strength and more than 4 times higher abrasion resistance were secured. From the mechanical experiments results, the optimum mixing ratio of the VAE polymer was determined to be 10%. As a result of application and monitoring, it shows that it has excellent resistance to cracking, discoloration, impact, and scratch as well as bond performance compared to the cement based floor mortar.

An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction. (바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구)

  • Choi, Kyung-Suk;Seok, Won-Kyun;Mauk, Ji-Wook;Shin, Yi-Seop;Kim, Hyung-Joon;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

The application study on the super flowing the polymer based cement mortar (초유동화 폴리머시멘트몰탈의 실용화연구)

  • 손형호;이종열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.36-41
    • /
    • 1995
  • Recently, as the problems according to the deteriorated structure were gathering sterength, there were required the advent of the high peformance for polymer ceme at compostie in building constrution devision. The polymer cement mortar was developed for improvements of the various problems in ordinary cement mortar. finishing method using the super flowing polymer-based self levelling mortar for concrete slab and floor.

  • PDF

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

Properties of the Strength and Thermal Conductivity of Floor Cement Morte Using Copper Fiber (동섬유를 이용한 바닥마감용 시멘트 모르터의 강도 및 열전도 특성)

  • Park, Eun-Bae;Yin, Ji-Feng;Cheong, Sung-Chul;Hong, Sang-Hee;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.173-176
    • /
    • 2000
  • The objective of this paper is to investigate the properties of strength and thermal conductivity of floor cement mortal using copper fiber. Compressive strength thermal conductivity and length change are tested. According to the experimental results, compressive strength, thermal strength and thermal conductivity of mortar using copper finer are shown to be increased with increase of the contents of copper fiber and the aspect ratio. In case of length change of cement mortar using copper fiber also shows deline tendency compared with that of plain mortar.

  • PDF

A Study on the Crack Prevention of the Floor Surface Finishing Mortar adding Chemical Admixtures in Apartment Houses (혼화제를 사용한 공동주택 바닥마감 모르타르의 균열저감에 관한 연구)

  • Lee, Dong-Un
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1541-1548
    • /
    • 2015
  • In this study, strengthening methods of floor surface finishing mortar are investigated to prevent the cracks using crack inhibitor agents, water reducer agent and resin. As a results, The number of crack and compressive strength of the specimen containing water reducer agent or resin had more effective than other specimens containing inhibitor agents at 7 days. And the highest compressive strength specimen showed the relatively no crack, but the lowest compressive strength specimen showed a lot of crack. Therefore the relationship between the crack growth and the compressive strength had proportional connection. A base on the mock-up test, long-term monitoring of the on-site applied to mixing design type3 showed the few cracks.

A Study on the Hybrid Floor Adhesive System with Crack Resistance (균열대응성을 보유한 유·무기 복합 하이브리드 바닥 접착시스템 연구)

  • Ko, Hyo-Jin;Kim, Rae-Hwan;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.171-172
    • /
    • 2023
  • In order to reduce crack defects caused by the behavior of concrete during floor tile construction, this paper introduced a hybrid floor adhesion system that first constructs an organic adhesive with crack correspondence and attaches tiles with inorganic mortar.

  • PDF

Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling (분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상)

  • Park, Joo-Saeng;Kim, Se-Jong;Lee, Sang-Joon
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.4
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

Research on the quality characteristics of each type of floor dry mortar (바닥용 건조 시멘트 모르타르 종류별 품질특성에 관한 연구)

  • Lee, Ji-Hwan;Kim, Jin-Sik;Kim, Hye-Won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.157-158
    • /
    • 2022
  • A problem arose about the lack of strength of dry mortar for flooring. To solve the problem of lack of strength, a high-strength dry mortar was applied. However, problems arose about the increase in the amount of cracks. It is necessary to analyze the causes of the increase in the amount of cracking in high-strength dry mortar and take countermeasures.

  • PDF