• Title/Summary/Keyword: floor materials

Search Result 710, Processing Time 0.023 seconds

Study on the Development of 340MPa Grade Super Formable High Strength Steel Sheets (340MPa 급 초고성형성 고강도강판 개발에 관한 연구)

  • Kim, Yong-Hee;Lee, Young-Soo;Lee, Oh-Yeon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.48-54
    • /
    • 2009
  • The demand for formable high-strength steel (HSS) sheets has recently increased to reduce the weight of automotive bodies. The 340MPa (Tensile Strength) grade steel sheets are widely used for body inner and outer panels. Especially, super formable 340MPa grade steel sheets with high r-value have an excellent deep drawability compared with the other 340MPa grade steel sheets. It is very available for a part such as rear floor, center floor and dash panels used conventional mild steels up to now. We developed a super formable HSS by optimization of chemical composition, texture control and heat treatment control. It has good mechanical properties with excellent formability (tensile strength: 343MPa, elongation: 41.1% and $\bar{r}=2.1$).

New bone formation in the maxillary sinus without bone grafts:Covering of lateral window with non-resorbable membrane or bony window (골이식재를 사용하지 않은 상악동 거상술:골창의 패쇄방법에 따른 치험례)

  • Son, Dong-Seok;Lee, Ji-Su;An, Mi-Ra;Sin, Hong-In
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.222-231
    • /
    • 2008
  • Various maxillary sinus floor augmentation techniques were common performed and in the most cases, many kinds of bone graft materials were used. The graft materials are autogenous bone or other biomaterials of human, animal or synthetic origin. But these cases report describes a new surgical technique by which dental implants are inserted in a void space created by elevating the sinus membrane without additional graft material in atrophic posterior maxilla. We created lateral bony window using piezoelectric device and elevated the schneiderian membrane in five patients and was repositioned with bony window in five patients, without any bone graft. From the clinical and histological results, it is found there is potential capacity for bone formation and placement of implants in the maxillary sinus without the use of bone grafts or bone substitutes.

  • PDF

The comparison of the tensile strength of fiber-reinforced composites according to the change of fiber orientat and fiber orientation angle in one direction (섬유배향과 일방향 섬유배향각 변화에 다른 복합재료의 인장강도 비교)

  • Kim Jin-Woo;Lee Jung-Ju;Lee Dong-Gi
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.284-287
    • /
    • 2004
  • After we experiment one direction fiber reinforced composites$(\theta\;=\;0^{\circ},\;J=1)$ to the X direction$(\theta\;=\;0^{\circ},\;J=1)$, we can say that fiber orientation efficiency and fiber orientation angle efficiency become lower. It is because the more the fabric is orientated in a equal direction with one direction fiber floor the more the load given from the exterior becomes shear rather than tension, even though one direction fiber floor gets the most of the exterior power. when fiber content ration is $10wt\%$, the fiber reinforcement efficiency of J=0.3 is similar with the fiber reinforcement efficiency of $\theta=30^{\circ}$ We also found that the fiber reinforcement efficiency of J=0.2 is similar with the fiber reinforcement efficiency of $\theta=20^{\circ}$ in case of $20wt\%$.

  • PDF

Application Review of Portable Slip Meter(ONO.PPSM) (휴대형 미끄럼시험기 (ONO.PPSM)의 적용성 검토)

  • Baek, Koen-Hyuk;Shin, Yoon-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.219-223
    • /
    • 2009
  • This paper is the result of investigation of ONO PPSM(ONO PORTABLE SLIP METER) by way of experiment to see the validity as a slip meter, ONO PPSM is a portable slip meter which was made up for the weak points of O-Y PSM(ONO-YOSHIOKA PULL SLIP METER) which takes an accurate measurement of the slip resistance but very heavy and hard to operate. In order to know the stability of the measurement result of ONO PPSM, we measured the slip resistance against 4 different kind of floor materials. As a result of this, we found out that the coefficient of variability of CSR' is less than 0.05. Also, we verified the relation between CSR' and CSR. more specifically by doing the slip test against 7 different kinds of inorganic matter floor materials. We increased the usability of ONO PPSM as a slip meter by suggesting the method of sharing the evaluation index of slip of CSR' and C.S.R.

  • PDF

Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material (목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석)

  • Seo, Jungki;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-359
    • /
    • 2017
  • Many researches and policies have been carried out for saving energy in buildings. However, there are a few studies of thermal characteristics of wood-based materials that have been widely used as structural materials and finishing materials in buildings. In this study, thermal bridging areas were found to investigate thermal performance of residential building using non wood-based materials and wood-based materials. And heat transfer analysis of 16 case studies according to composition of structural materials and finishing materials was conducted. Also in this experiment, Physibel Trisco was used as the heat transfer analysis simulation tool, which conforms to the calculation method of ISO 10211. Analytical modeling was also carried out according to the ISO 10211, and the boundary temperature conditions were set at room temperature $20^{\circ}C$ and outdoor temperature $-11.3^{\circ}C$ (Seoul standard) according to the energy saving design standard in South Korea. Applied structures are classified according to the cases of concrete structure with non wood-based finishing materials, concrete structure with wood-based finishing materials and wood structure. Analyzed building elements were divided into a wall, a roof, an interlayer floor and a bottom floor. As a result, it can be confirmed that the thermal bridge of the concrete structure and wood structure were caused by the geometrical and material causes. In addition, the structural thermal bridge was caused in the discontinuity of the insulation in the concrete structure. Also it was confirmed that the linear heat transfer coefficient of the wall decreases when the wood-based materials are applied to the concrete structure.

Measurement of Radon-222 Exhalation Rate from Building Materials by Using CR-39 Radon Cup (CR-39 라돈컵을 이용한 국산 전축자재의 라돈-222 방출율 측정)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.15-24
    • /
    • 1991
  • Radon-222 exhalation rate from several domestic building materials were experimentally measured by using radon cup method, in which a CR-39 plastic is used as a passive radon detector. The radon detection factor of CR-39 detector determined in a series of calibration experiments was $0.164{\pm}0.005(tracks\;cm^{-2}/Bq\;d\;m^{-3})$, which is consistent with those reported by other investigators. The radon exhalation rates of several building materials (brick, red brick, concrete block, granite plate, concrete floor and wall) ranges from $6.8{\times}10^{-6}\;(granite plate)\;to\;75.0{\times}10^{-6}Bq/m^2-sec(brick)$ with the increasing order of granite plate, red brick, concrete wall, concrete block, concrete floor and brick. It showed that the CR39 radon cup can be efficiently utilized in measuring the radon-222 gas exhalation rate from building materials.

  • PDF

A Study on the Improvement of Performance Standard and Classification for the Firestop Accreditation System (내화충전구조 인정제도의 성능기준 및 등급분류 개선에 관한 연구)

  • Lee, H.D.;Choi, Y.J.;An, J.H.;Jeong, A.Y.;Seo, H.W.;Park, Jin O
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.32-39
    • /
    • 2020
  • The fire compartments with fire-resistant construction are installed in the principal structural parts of a building in order to reduce damage in the event of a building fire. As a fire may spread through a crack in the fire compartment, the firestop with secured performance is used according to the procedure, methods, and standards specified in the detailed operation guideline. According to the current detailed operation guideline, vertical members (wall penetration) and horizontal members (floor penetration) are classified into different categories respective to each other for the classification of the firestop. Therefore, an accreditation applicant must apply for the performance test for each structure even if the wall and the floor have the same structure. Also, Grade T is used for the firestop that penetrates the fire compartment. However, in the case of foreign countries, the use of Grade F for the firestop is allowed even if it penetrates the fire compartment. The result of the precedent studies also showed that there was a significantly low possibility of fire to spread even if Grade F was applied for a metallic duct that penetrated the fire compartment. In this study, the improved scheme for the classification and performance standard of firestops was presented by analyzing the results of precedent studies regarding the firestop and domestic and overseas firestop qualification systems.

Unsteady Analysis of Indoor Radon in Apartment Buildings Considering Finishing Materials and Ventilation (마감재 및 환기를 고려한 공동주택 실내 라돈 농도의 비정상 해석)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.24-31
    • /
    • 2019
  • In this paper, we simulated a new apartment building by using radon emission test values from various building materials used as interior finishing materials. The simulations evaluated the radon concentration in the room according to the radon emissions and the ventilations for each type of finishing material (gypsum board, stone, tile and concrete). Overall concrete finish simulation case showed the highest concentration than the case using other materials due to the effect of wall area at the center of each room and the mean radon concentration at 1.5 m above the floor was slightly lower than the mean value at each center. In the case of the porch, pantry and bathroom, the radon concentration was high even when the same materials were used as in the other rooms.

Absorption Characteristics of Building Interior Decoration Materials (건축내장재의 흡음 특성)

  • Kang, Dae-Joon;Lee, J.W.;Lee, W.S.;Hong, J.K.;Jo, Y.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1190-1193
    • /
    • 2006
  • It is important to consider absorption characteristics of building interior decoration materials when we design a building and simulate acoustics in a room. The purpose of this study is to accumulate acoustic data on building interior decoration materials and give a basic data for improving absorption performance by testing absorption coefficient of 9 types of ceiling materials, 14 types of wall paper and 20 types of floor papers.

  • PDF

Sound Absorption Characteristics of Building Interior Decoration Materials (건축내장재의 흡음 특성)

  • Kang, Dae-Joon;Lee, J.W.;Gu, J.H.;Park, H.K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.201-206
    • /
    • 2007
  • It is important to consider the sound absorption characteristics of building interior decoration materials when we design a building and simulate acoustics in a room. The purpose of this study is to accumulate acoustic data on building interior decoration materials and give a basic data for improving the sound absorption performance by testing the sound absorption coefficients of 9 types of ceiling materials, 14 types of wall papers and 20 types of floor papers.