An Analysis of Wind environment on the Basis of reclassified Zoning (주거지역 종세분화에 따른 바람환경 분석)

  • Lee, Jun-Young;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.109-112
    • /
    • 2009
  • Various environmental problems due to the rapid industralization and urbanization have been worsened as much as to threaten the environmental restitution of globe and become a critical international issue. Korean government presented the green growth as a new state vision for 60 years afterwards and is making efforts to solve the environmental problems. Daegu metropolitan city has faced various environmental problems including overpopulation of cities, traffic pollution, household wastes and green zone problem because of urbanization for the last decades. As such urbanism continues, the quality of residential environment is rapidly deteriorating and the intensive use of land leads to increase of building area raising the temperature of cities. Therefore there have been demands for the healthy, pleasant and satisfying residential environment and the improvement of residential environment and such recognition rises from society in full measure. Nevertheless the current residential complex concentrates only on raising the efficiency of land use. Related laws in the past(Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) tried to prepare a standard to segmentalize the building-to-land ratio, floor area ratio and regulations of number of floors vertically, but currently it is abolished and the regulations are becoming eased. The purpose of this study was to analyze the characteristics of the floating wind before and after the vertical segmentation of residential areas(Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) by using KLAM_21, a model that enables analysing and predicting the flow and generation of clod wind, and to present a plan to improve the quality of residential areas afterwards when developing building lot and re-developing housing areas.

  • PDF

A novel approach for the definition and detection of structural irregularity in reinforced concrete buildings

  • S.P. Akshara;M. Abdul Akbar;T.M. Madhavan Pillai;Renil Sabhadiya;Rakesh Pasunuti
    • Structural Monitoring and Maintenance
    • /
    • v.11 no.2
    • /
    • pp.101-126
    • /
    • 2024
  • To avoid irregularities in buildings, design codes worldwide have introduced detailed guidelines for their check and rectification. However, the criteria used to define and identify each of the plan and vertical irregularities are specific and may vary between codes of different countries, thus making their implementation difficult. This short communication paper proposes a novel approach for quantifying different types of structural irregularities using a common parameter named as unified identification factor, which is exclusively defined for the columns based on their axial loads and tributary areas. The calculation of the identification factor is demonstrated through the analysis of rectangular and circular reinforced concrete models using ETABS v18.0.2, which are further modified to generate plan irregular (torsional irregularity, cut-out in floor slab and non-parallel lateral force system) and vertical irregular (mass irregularity, vertical geometric irregularity and floating columns) models. The identification factor is calculated for all the columns of a building and the range within which the value lies is identified. The results indicate that the range will be very wide for an irregular building when compared to that with a regular configuration, thus implying a strong correlation of the identification factor with the structural irregularity. Further, the identification factor is compared for different columns within a floor and between floors for each building model. The findings suggest that the value will be abnormally high or low for a column in the vicinity of an irregularity. The proposed factor could thus be used in the preliminary structural design phase, so as to eliminate the complications that might arise due to the geometry of the structure when subjected to lateral loads. The unified approach could also be incorporated in future revisions of codes, as a replacement for the numerous criteria currently used for classifying different types of irregularities.

VLSI Design of a 2048 Point FFT/IFFT by Sequential Data Processing for Digital Audio Broadcasting System (순차적 데이터 처리방식을 이용한 디지틀 오디오 방송용 2048 Point FFT/IFFT의 VLSI 설계)

  • Choe, Jun-Rim
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.65-73
    • /
    • 2002
  • In this paper, we propose and verify an implementation method for a single-chip 2048 complex point FFT/IFFT in terms of sequential data processing. For the sequential processing of 2048 complex data, buffers to store the input data are necessary. Therefore, DRAM-like pipelined commutator architecture is used as a buffer. The proposed structure brings about the 60% chip size reduction compared with conventional approach by using this design method. The 16-point FFT is a basic building block of the entire FFT chip, and the 2048-point FFT consists of the cascaded blocks with five stages of radix-4 and one stage of radix-2. Since each stage requires rounding of the resulting bits while maintaining the proper S/N ratio, the convergent block floating point (CBFP) algorithm is used for the effective internal bit rounding and their method contributed to a single chip design of digital audio broadcasting system.

Experimental Study on Efficiency of Floating Vertical Axis Wind Turbine with Variable-Pitch (부유식 가변 피치형 수직축 풍력발전기의 발전효율에 관한 실험 연구)

  • Kim, Jae-Heui;Jo, Hyo-Jae;Hwang, Jae-Hyuk;Jang, Min-Suk;Lee, Byeong-Seong
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.202-207
    • /
    • 2018
  • This paper presents the efficiency of a floating vertical axis wind turbine with variable-pitch. A model was designed to use the lift force and drag force for blades with various pitch angles. The blade's pitch angle is controlled by the stopper. To validate the efficiency of the wind turbine discussed in this paper, a model test was carried out through a single model efficiency experiment and wave tank experiment. The parameters of the single model efficiency experiment were the wind speed, electronic load, and pitch angle. The wave tank experiment was performed using the most efficient pitch angle from the results of the single model efficiency experiment. According to the results of the wave tank experiment, the surge and pitch motion of a structure slightly affect the efficiency of a wind turbine, but the heave motion has a large effect because the heights of the wind turbine and wind generator are almost the same.

Investigation of the Rotational Displacement of the Suction Anchor Subjected to the Inclined Pullout Load in Silty Sand (사질토 지반에서 경사 인발 하중을 받는 석션 앵커의 회전 거동 평가)

  • Bae, Jun-Sik;Jeong, Yeong-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.267-273
    • /
    • 2020
  • Suction anchors are used for floating structures because they have advantages in installation and stability. Recently, the demand for floating structures requiring low allowable displacement has increased. Thus, it is strongly suggested that the displacement of the suction anchor be evaluated. However, conventional studies regarding suction anchors have concentrated on the capacity of the anchor, and research on the displacement of the anchor is limited. In particular, rotation is the primary behavior of a suction anchor subjected to an inclined load, and related information has been insufficient. Therefore, the main objective of this paper is to investigate the rotation behavior of a suction anchor via centrifuge model tests. The experimental parameters are the inclination of the pull-out load, anchor dimensions, and aspect ratio. The rotation values of suction anchors were compared using a series of load-rotation curves. The results show that the inclination of the load has a dominant influence on the rotation behavior of the suction anchor.

The Change Detection from High-resolution Satellite Imagery Using Floating Window Method (이동창 방식에 의한 고해상도 위성영상에서의 변화탐지)

  • Im, Yeong-Jae;Ye, Cheol-Su;Kim, Gyeong-Ok
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.117-122
    • /
    • 2002
  • Change detection is a useful technology that can be applied to various fields, taking temporal change information with the comparison and analysis among multi-temporal satellite images. Especially, change detection that utilizes high-resolution satellite imagery can be implemented to extract useful change information for many purposes, such as the environmental inspection, the circumstantial analysis of disaster damage, the inspection of illegal building, and the military use, which cannot be achieved by lower middle-resolution satellite imagery. However, because of the special characteristics that result from high-resolution satellite imagery, it cannot use a pixel-based method that is used for low-resolution satellite imagery. Therefore, it must be used a feature-based algorithm based on the geographical and morphological feature. This paper presents the system that builds the change map by digitizing the boundary of the changed object. In this system, we can make the change map using manual or semi-automatic digitizing through the user interface implemented with a floating window that enables to detect the sign of the change, such as the construction or dismantlement, more efficiently.

  • PDF

Measurement and analysis of indoor corridor propagation path loss in 5G frequency band (5G 주파수 대역에서의 실내 복도 전파 경로손실 측정 및 분석)

  • Kim, Hyeong Jung;Choi, Dong-You
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.5
    • /
    • pp.688-693
    • /
    • 2022
  • In this paper, channel propagation path loss was measured in building corridors for frequency bands of 3.7 GHz and 28 GHz, which are used in 5G mobile communication, and compared and analyzed with CI (Close-In) and FI (Floating-Intercept) channel models. To measure the propagation path loss, the measurement was performed while moving the receiver (Rx) from the transmitter (Tx) by 10 m. As a result of the measurement, the PLE (Path Loss Exponent) values of the CI model at 3.7 GHz and 28 GHz were 1.5293 and 1.7795, respectively, and the standard deviations were analyzed as 9.1606 and 8.5803, respectively. In the FI model, 𝛼 values were 79.5269 and 70.2012, 𝛽 values were -0.6082 and 1.2517, respectively, and the standard deviations were 5.8113 and 4.4810, respectively. In the analysis results through the CI model and the FI model, the standard deviation of the FI model is smaller than that of the CI model, so it can be seen that the FI model is similar to the actual measurement result.

Evaluation of the Location Efficiency of Fine Dust Shelters Considering Vulnerable Population in Seoul (취약계층을 고려한 미세먼지 쉼터 입지 효율성 평가)

  • Lim, Jae Kwon;Lee, Hye Kyung
    • Journal of KIBIM
    • /
    • v.12 no.4
    • /
    • pp.104-115
    • /
    • 2022
  • Fine Dust in Korea has been classified as a social disaster since 2019 due to continuous increase in concentration of Particulate Matter 10(PM 10) and PM 2.5. The fine dust issue has negative physical and mental impacts, especially on vulnerable population including children and the elderly. Seoul metropolitan government have installed fine dust shelters since 2019. However, there is a lack of research that evaluates spatiotemporal distribution of these facilities. Therefore, the first aim of this study is to find the relationship between PM levels and dust scattering construction sites, or air pollutant emission sites through in depth spatial analyses. The second purpose is to analyze the spatial distribution of PM shelters in Seoul, and to evaluate the location efficiency of them. Kernel density, krigging, and network analyses were conducted, and floating population was considered instead of census data for this research. The reults of network analysis based on the road system showed that Yangcheon-gu, Songpa-gu, Seongbuk-gu, and Dobong-gu were found to need additional fine dust shelters. Also, the results from analyzing the floating population that includes children and the elderly showed that Songpa-gu, Seodaemun-gu, Gangdong-gu, Seocho-gu, and Dongdaemun-gu need more placements of find dust shelters. The results of this study are expected to provide implications for urban planners to enhance find dust shelter placement in urban areas, and vulnerable population issues would be considered in many ways.

A Study on the Characteristics of Organic Concept and Interpretation at F. L. Wright and T. Ito's Architecture - Focus on Wright's Robie House and Ito's Sendai Mediatheque - (라이트와 이토 건축의 유기적 개념과 해석 특성에 관한 연구 - 라이트의 로비 하우스와 이토의 센다이 미디어 테크를 중심으로 -)

  • Park, Hyung-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.23-32
    • /
    • 2013
  • This study represents something in common and differences of organic characteristics between early modern architecture and contemporary architecture analysing F. L. Wright's Robie House and Toyo Ito's Sendai Mediatheque. A natural organic body cannot be separated from the natural environment, and each part of an architecture has each own property and forms a whole at the same time. That is a basic concept of organic architecture, and a framework for analysis is set up based on it. The followings are similarities and differences of organic concept and interpretation between Wright's Robie House and Ito's Sendai Mediatheque First, Wright' Robie house unites with the natural surrounding, using a physically close connection to the ground. In contract, Ito's Mediatheque shows characteristics of noncentural and fluidic space that are metaphorically reflecting tangible and intangible of factors in modern city, where there is an ambiguous physical boundary between architecture and urban environment. Next, floors, walls and ceilings of Wright's housing as for basic building blocks are physically separated and at the same time form formative unity from the point of view of a physical and structural organic body. And continuous flow of faces of separated walls form an organism united with the nature from a physical aspect. On the contrary to this, there is an no-boudary and floating organic architecture of integrated structure from ambiguous setting of relation between architecture and urban space in Ito's architecture. Especially, Mediatheque shows semantic integration of floating urban environmental factors through horizontal and vertical integration of horizontal slabs, vertical pipes, and skins. Last, horizontal and vertical factors of Wright' Housing is appreciated as an basic experienced structure in terms of spacial perception and fluidic inner spaces in Wright's housing is completed with a series of spatial experiences in a visual sense. On the other hand, no-boundary and floating space of Ito's architecture accept user's physical and virtual body. Especially, there is an integration transcending beyond time and space, accepting an imaginary body and events with the course of time at Ito's Mediatheque.

Tethers tension force effect in the response of a squared tension leg platform subjected to ocean waves

  • El-gamal, Amr R.;Essa, Ashraf;Ismail, Ayman
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.327-342
    • /
    • 2014
  • The tension leg platform (TLP) is one of the compliant structures which are generally used for deep water oil exploration. With respect to the horizontal degrees of freedom, it behaves like a floating structure moored by vertical tethers which are pretension due to the excess buoyancy of the platform, whereas with respect to the vertical degrees of freedom, it is stiff and resembles a fixed structure and is not allowed to float freely. In the current study, a numerical study for square TLP using modified Morison equation was carried out in the time domain with water particle kinematics using Airy's linear wave theory to investigate the effect of changing the tether tension force on the stiffness matrix of TLP's, the dynamic behavior of TLP's; and on the fatigue stresses in the cables. The effect was investigated for different parameters of the hydrodynamic forces such as wave periods, and wave heights. The numerical study takes into consideration the effect of coupling between various degrees of freedom. The stiffness of the TLP was derived from a combination of hydrostatic restoring forces and restoring forces due to cables. Nonlinear equation was solved using Newmark's beta integration method. Only uni-directional waves in the surge direction was considered in the analysis. It was found that for short wave periods (i.e., 10 sec.), the surge response consisted of small amplitude oscillations about a displaced position that is significantly dependent on tether tension force, wave height; whereas for longer wave periods, the surge response showed high amplitude oscillations that is significantly dependent on wave height, and that special attention should be given to tethers fatigue because of their high tensile static and dynamic stress.