• 제목/요약/키워드: flame resistance

검색결과 190건 처리시간 0.03초

Creation of Diamond/Molybdenum Composite Coating in Open Air

  • Ando, Yasutaka;Tobe, Shogo;Tahara, Hirokazu
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1313-1314
    • /
    • 2006
  • For improvement of wear resistance property of atmospheric thermal plasma sprayed molybdenum (Mo) coating, diamond deposition on the atmospheric plasma sprayed molybdenum coating by the combustion flame chemical vapor deposition (CFCVD) has been operated. In this study, to diminish the thermal damage of the substrate during operation, a thermal insulator was equipped between substrate and water-cooled substrate holder. Consequently, diamond particles could be created on the Mo coating without fracture and peeling off. From these results, it was found that this process had a high potential in order to improve wear resistance of thermal sprayed coating.

  • PDF

Tencel FR/Cotton 복합원단의 물리적 특성 및 난연성에 관한 연구 (Study on the Physical Properties and Flame Retardancy of Tencel FR/Cotton Complex Knit Fabrics)

  • 김현아;김현철
    • 한국의류학회지
    • /
    • 제36권7호
    • /
    • pp.703-713
    • /
    • 2012
  • This study analyzed the physical properties and flame retardancy of Tencel FR/Cotton complex knit fabrics in order to satisfy two aspects of eco-friendliness and functionality. The flame retardant (FR) treatment of complex knit fabrics was applied by a pad-dry-cure method for additional functionality. Tensile strength, extension, bursting strength, LOI, and flame retardancy were measured by the KS (Korean Standard) K manual. The hand value knit fabrics were measured by KES-FB system. Subsequently, tensile strength and extension of wale and tensile strength of course increased in tandem with the Tencel FR yarn content. Tencel FR/Cotton complex knit fabrics were suitable for summer-weight and for baby clothes through the KES-FB system measurements. The bursting strength of Tencel FR/Cotton complex knit fabrics decreased as the contents of the Tencel FR increased; in addition, LOI increased as the contents of Tencel FR increased. This was due to the Tencel FR flame resistance function; however, the tensile strength decreased. The optimum fiber content of Tencel FR/cotton content was 1:1. The optimum conditions of flame retardant treatment were a treatment temperature $130^{\circ}C$ and the concentration of finishing agent and assistance binder (AR4260) was 35% and 1%, respectively.

마이크로파 가열 목재의 방염·방충 복합 보존처리 특성 (Characteristics of Flame Retardent and Mothproof Conservation of Microwave Heated wood)

  • 김종근;박철우;윤태호;임남기
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권3호
    • /
    • pp.234-246
    • /
    • 2013
  • 목조주택의 골조 및 실내 외 마감용으로 사용되는 침엽수 구조재를 대상으로 방염 방충 보존처리제가 혼합된 약제에 마이크로파 가열 후 열기를 지닌체 침지하여 복합적인 기능화를 부여한 후 목재의 건조 스케줄, 방염 시험에 의한 화재 저항성과 흰개미에 의한 내충해성, 혼합 약제의 침투성 분석을 실시한 결과 마이크로파로 3 kW로 5분 급속 가열된 시험편은 목표 온도 및 함수율을 만족하는 것으로 나타났으며, 인산염과 헤테로고리화합물계가 혼합된 약제에 120분 침지할 경우 가장 높은 중량 증가율을 가지는 것으로 나타났다. 또한 방염 후 처리 물품 시험을 실시한 결과 인산염과 혼합된 약제는 방염기준을 모두 만족하는 것으로 나타났으며, 흰개미 투입 후 7일 사충율을 확인한 결과 인산염과 헤테로고리화합물계 혼합 약제 침투 시험편의 경우 96% 이상 높은 사충율을 나타냄으로서 가장 우수한 특성을 가지는 것으로 나타났다. 목재 내부로 약제 침투성 분석을 실시한 결과 목재 세포내부 전면에 있어 혼합약제가 침투된 것으로 나타나 목재의 방염성 및 방충 저항성 등에서 우수한 성능의 발현은 혼합 약제의 균일한 침투때문으로 판단된다.

기능성화 산화 그래핀과 폴리인산암모늄을 이용한 직물 난연성 향상 (Enhanced Flame Retardancy of Cotton Fabric by Functionalized Graphene Oxide and Ammonium Polyphosphate)

  • 가동원;장성온;정현숙;진영호
    • Composites Research
    • /
    • 제33권4호
    • /
    • pp.177-184
    • /
    • 2020
  • 난연 의류는 화염 및 고온 환경 속에서 착용자의 원활한 임무 수행을 돕고 추가적인 피해 확산을 방지한다. 그러나 기존 난연 의류의 높은 중량과 열 피로도는 개선이 필요하며, 친환경적인 방법으로 제작된 가볍고 편리한 난연 의류 개발이 요구되고 있다. 최근 인을 함유한 난연 물질 코팅으로 섬유에 난연성을 부여한 사례가 보고되고 있으나 이들은 국내외 방화복 및 난연 전투복 기준에 적합한 수준으로 발전될 필요성이 있다. 본 연구에서는 깊은 용융 용매로 기능성화된 산화 그래핀과 폴리인산암모늄을 동시에 섬유에 코팅하는 친환경적인 대량생산 공정을 제시한다. 코팅된 섬유는 열무게 분석(Thermogravimetric analysis), 수직불꽃저항성 시험(ASTM D6413), 콘칼로리미터법(ISO 5660-1), 한계 불꽃 확신 속도 시험(ISO 15025)으로 열 안정성 및 난연성이 시험되었다. 기능성화 산화그래핀과 폴리인산암모늄이 동시에 코팅된 직물은 단일 물질 코팅 직물보다 우수한 난연성을 보였고, 연소 이후에도 탄화된 부분의 팽창 효과로 섬유의 형상을 유지하는 것이 관찰되었다. 난연 직물의 세탁 안정성을 위해 추가적인 발수 처리 또한 시도되었다.

내충격성 및 전기적 특성 향상을 위한 반도전성 난연컴파운드의 나노융복합 소재기술에 대한 연구 (A study on Nano-convergence material technology of semiconductive flame retardant compound to improve impact resistance and electrical properties)

  • 한재규;전근배;박동하
    • 한국융합학회논문지
    • /
    • 제12권1호
    • /
    • pp.193-198
    • /
    • 2021
  • 본 연구에서는 초고압(Extra High Voltage) 케이블의 방식층(Oversheath)에 사용되는 반도전성 난연컴파운드의 보다 우수한 내충격성 및 전기적 특성을 만족할 수 있는 나노융복합 소재기술에 대해 연구하였다. 반도전성 난연컴파운드에 사용되는 도전성 카본블랙 일부를 CNT(carbon nano tube)로 대체하였으며, 이때 물성변화를 분석하였다. 전기적 특성이 현격하게 뛰어난 탄소나노튜브의 적용을 통해 소량의 전도성필러 처방으로도 보다 우수한 전기적 특성을 부여할 수 있게 된다. 또한, 컴파운드 기준 전체 필러량이 감량됨에 따라서 가공성이 향상되며, 특히 유연성 및 내충격성이 향상되기 때문에 케이블의 내구성 향상에 기여할 것으로 기대된다.

합판 종류에 따른 기능성 오일스테인의 성능 평가 (Performance Evaluation of Functional Oil Stain by Plywood Type)

  • 이주원;이창우;황우준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.35-36
    • /
    • 2022
  • In order to supplement the flame-retardant performance of oil stain, which can prevent wooden buildings from contamination, (NH4)2HPO4, a phosphorus flame-retardant, was added to oil stain and applied for each type of plywood, and an experiment was conducted. The addition rate was set to 0-60%, but white powder appeared on the surface of plywood from 40% and thus it was impossible to experiment, so the maximum addition rate was selected as 30%. As a result of the experiment, acacia plywood had the best performance. As the rate of addition of the flame retardant increased, the remaining time and carbonization length of all plywood decreased, but the carbonization length of the MDF plywood was not met with the standards.

  • PDF

하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

$Al_2O_3$세라믹 용사피막의 특성개선에 관한 연구 (A Study on the Improvement of Properties of Sprayed $Al_2O_3$ Ceramic Coating Layer.)

  • 김정일;이주원;최영국;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.49-58
    • /
    • 2000
  • Thermal spraying is one of the most common surface coating techniques to be used for many applications and flame spraying covers a wide range of different materials which can be coated onto various substrates. The purpose of this study is to investigate the effects of mixed ratio in composite coatings on the mechanical and anti-corrosion properties. The five different types of composite coatings were made with $Al_2O_3$ ceramic and Ni-alloy powder on the mild steel substrate by flame spraying method. The mechanical properties such as microhardness, adhesive strength and erosion resistance and corrosion resistance were tested for the sprayed coating specimens. The results obtained are summarized as follows; 1. The composite coating layers greatly improve the microstructure, erosion resistance and adhesive strength by increasing the content of Ni-Al alloy. 2. Microhardness of the compsite coating layer is decreased by increasing the content of Ni-Al alloy. 3. The anti-corrosion properties is considerably improved by increasing the compsite rate of Ni-Al alloy.

  • PDF

나노 탄화규소(SiC) 슬러리로 코팅된 메타-아라미드 직물의 특성 (Characteristics of Meta-aramid Fabrics Coated with Slurry of Nanoscale SiC Particles)

  • 박종현;이선영;원종성;이응보;김의화;이승구
    • 한국염색가공학회지
    • /
    • 제29권3호
    • /
    • pp.131-138
    • /
    • 2017
  • Most of high performance fabrics for the car racing protective clothing have been developed to have thermal resistance, flame retardant property, impact resistance and anti-frictional properties to protect the racer from the crucial accident. In this study, the meta-aramid fabric, which has inherent flame retardant, was coated with nanoparticles of SiC to enhance the impact resistance and anti-friction properties. Uniform coating of the nanoparticles onto the fabrics was obtained by using tape casting method. As the experimental parameters, size and content of the SiC nanoparticle were varied with the coating conditions of the fabric surface. The effects of the nanoparticle coating on the properties of meta-aramid fabric were examined with various instrumental analyses such as SEM, tensile strength and abrasion test.

목질바닥재의 착화특성에 관한 연구 (A Study on the Ignitibility of Wooden Flooring)

  • 김해림;김영탁;박영주;이해평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.397-402
    • /
    • 2008
  • In this study, we analyzed the ignitibility of the wooden floorings used as the finishing materials for interior with the flammability tester and the ignition point tester. Also we analyzed the limit oxygen index(LOI) using the oxygen index tester and the flame resistance of the wooden floorings. We confirmed that all of the samples had a excellent flame resistance. The ignitibility of the floorings were ranked as the material lumber>the strengthening flooring>the veneer board(1)>the veneer board(2).

  • PDF