• Title/Summary/Keyword: fixed source

Search Result 597, Processing Time 0.031 seconds

Comparison of InGaef etching $BCl_3,\;BCl_3/Ar\;and\;BCl_3/Ne$ inductively coupled plasmas ($BCl_3,\;BCl_3/Ar,\;BCl_3/Ne$ 유도결합 플라즈마에 의한 InGaP 건식 식각 비교)

  • Baek, In-Kyoo;Lim, Wan-Tae;Lee, Je-Won;Jo, Guan-Sik;Jeon, Min-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.361-365
    • /
    • 2003
  • Planar Inductively Coupled Plasma (PICP) etching of InGaP was performed in $BCl_3,\;BCl_3/Ar\;and\;BCl_3/Ne$ plasmas as a function of ICP source power ($0\;{\sim}\;500\;W$), RIE chuck power ($0\;{\sim}\;150\;W$), chamber pressure ($5\;{\sim}\;15\;mTorr$) and gas composition of $BCl_3/Ar\;and\;BCl_3/Ne$. Total gas flow was fixed at 20 sccm (standard cubic centimeter per minute). Increase of ICP source power and RIE chuck power raised etch rate of InGaP, while that of chamber pressure reduced etch rate. We also found that some addition of Ar and Ne in $BCl_3$ plasma improved etch rate of InGaP. InGaP etch rate was varied from $1580\;{\AA}/min$ with pure $BC_3\;to\;2800\;{\AA}/min$ and $4700\;{\AA}/min$ with 25 % Ar and Ne addition, respectively. Other process conditions were fixed at 300 W ICP source power, 100 W RIE chuck power and 7.5 mTorr chamber pressure. SEM (scanning electron microscopy) and AFM (atomic force microscopy) data showed vertical side wall and smooth surface of InGaP at the same condition. Proper addition of noble gases Ar and Ne (less than about 50 %) in $BCl_3$ inductively coupled plasma have resulted in not only increase of etch rate but also minimum preferential loss and smooth surface morphology by ion-assisted effect.

  • PDF

Design of High Efficiency Power Amplifier for Parametric Array Transducer using Variable Output Voltage AC/DC Converter (가변출력전압 AC/DC 컨버터를 이용한 파라메트릭 어레이 트랜스듀서용 고효율 전력증폭기의 설계)

  • Shim, Jae-Hyeok;Lee, Chang-Yeol;Kim, Seul-Gi;Kim, In-Dong;Moon, Won-Kyu;Lee, Jong-Hyeon;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.364-375
    • /
    • 2014
  • Parametric array transducers are used for long-range and highly directional communication in an underwater environments. The power amplifiers for parametric array transducers should have sufficient linear output characteristic and high efficiency to avoid communication errors, system heating, and fuel problems. But the conventional power amplifier with fixed source voltage is very low efficient due to large power loss by the big difference between the fixed source voltage and the amplifier output voltage. Thus to solve the problems this paper proposes the high efficiency power amplifier for parametric array transducers. The proposed power amplifier ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier and furthermore gets high efficiency by applying the envelope tracking technique that variable source voltage tracks the envelope of the amplified signal. Also the paper suggests the detailed circuit topology and design guideline of class B push-pull type amplifier and variable output voltage AC/DC converter. Its characteristics are verified by the detailed simulation and experimental results.

Study on Organic Rankine Cycle (ORC) for Maximum Power Extraction from Low-Temperature Energy Source (저온 열원으로부터 최대 동력을 생산하기 위한 유기랭킨사이클(ORC)에 관한 연구)

  • Kim, Kyoung-Hoon;Han, Chul-Ho;Kim, Gi-Man
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.73-79
    • /
    • 2011
  • ORC(organic Rankine cycle) has potential of reducing consumption of fossil fuels and has many favorable characteristics to exploit low-temperature heat sources. This work analyzes performance of ORC with superheating using low-temperature energy sources in the form of sensible energy. Maximum mass flow rate of a working fluid relative to that of a source fluid is considerd to extract maximum power from the sources. Working fluids of R134a, $iC_4H_{10}$ and $C_6C_6$, and source temperatures of $120^{\circ}C$, $200^{\circ}C$ and $300^{\circ}C$ are considered in this work. Results show that for a fixed source temperature thermal efficiency increases with evaporating temperaure, however net work per unit mass of source fluid has a maximum with respect to the evaporating temperature in the range of low source temperature. Results also show that the maximum power extraction is possible with R134a for the source temperature of $120^{\circ}C$, with $iC_4H_{10}$ for $200^{\circ}C$, and with $C_6C_6$ for $300^{\circ}C$.

A Study of Enemy Aptitude of Pistol Sound Source for Space Estimation (공간평가를 위한 피스톨음원의 적정성에 관한 연구)

  • Shon, Jang-Ryul;Kim, Jung-Joong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.320-328
    • /
    • 2005
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, how exactly through space sound (sound source) that wish to deliver from indoor can be passed method to do quantification and evaluate quantity of sound by method to serve indoor architectural acoustics estimation summer period and methods to estimate definition propose. This Study searches special quality of sound source about MLS signal that is occurred short-answer sound source (pistol sound source) and nondirectional speaker among indoor sound estimation method, and measure and analyzed reverberation time (RT60), definition (C80, D50) by regulation of each ISO 3382 in age place (classroom, hall, gymnasium). Analysis result and sound factor among could know that d of two sound sources converges in measurement error extent about reverberation time (RT60) of analysis incidental and sound factors and value shows change irregularly about sound factor of D50, C80, pistol sound source judged there is problem. Also, could know that problem is happened in deflection except reverberation time is in deflection analysis with wave that measure each in fixed distance in branch. Finally, when differ size of sound source and measure about change of sound pressure level in case measure sound pressure level giving difference about 10 dB, sound factor could know that there is no different effect.

Development of Multi-Purpose Variable Polarization Imaging System for Clinical Diagnosis (임상 진단용 다목적 가변 편광 영상장치 개발)

  • Bae, Young-Woo;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.265-270
    • /
    • 2007
  • Polarization imaging systems have been widely used to selectively characterize skin lesions. Nevertheless, current systems are used in single-mode due to the limitations of a fixed polarization mode and a single-working distance of light source, in which uniform light distribution is achieved on target area. To address such limitations, we developed a variable polarization imaging system based on multi-working distance of light source for various clinical diagnoses. In this study, we characterize the imaging system and present experiment results demonstrating its clinical usefulness. The imaging system consists of a CCD color camera, linear polarization filters, and a single-layered LED ring light source which provides uniform light distribution at multi-working distances. The first polarizer was placed on the light source and the second polarizer placed on objective lens provides continuous linear polarization angle from $0^{\circ}\;to\;90^{\circ}$. The clinical efficacy of the imaging system was investigated by acquiring and analyzing clinical images of skin wrinkle and dental plaque. With the experiments, we verified the potential usefulness of the imaging system for other clinical applications.

Measurement of Blood Oxygen Saturation System and LavVIEW Program Using Broad-band Light Source (광대역 광원을 이용한 혈중 산소포화도의 측정 시스템 및 랩뷰 프로그램)

  • Cui, Jin Shi;Shin, Dong Ho;Song, Chul Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.2
    • /
    • pp.128-137
    • /
    • 2015
  • Blood oxygen saturation ($SpO_2$) is so important to be called bio-signal of the fifth. The measurement of blood oxygen saturation based on broad-ban light source has advantages of simple testing facility and easy understanding. This paper proposes a LabVIEW program which measures blood oxygen saturation based on broad-band light source. It combines LabVIEW and MATLAB, utilizing different light absorptions of oxyhemoglobin and deoxyhemoglobin in the visual wavelength range of 450nm-750nm to determine blood oxygen saturation. In order to improve accuracy through reducing the impact of hand shaking, the probe is fixed to the motor stage and then move a constant distance between the probe and the sample to be measured. Experimental results show that the proposed method noticeably increases the accuracy and saves time compared with the conventional methods.

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

Verification of multilevel octree grid algorithm of SN transport calculation with the Balakovo-3 VVER-1000 neutron dosimetry benchmark

  • Cong Liu;Bin Zhang;Junxia Wei;Shuang Tan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.756-768
    • /
    • 2023
  • Neutron transport calculations are extremely challenging due to the high computational cost of large and complex problems. A multilevel octree grid algorithm (MLTG) of discrete ordinates method was developed to improve the modeling accuracy and simulation efficiency on 3-D Cartesian grids. The Balakovo-3 VVER-1000 neutron dosimetry benchmark is calculated to verify and validate this numerical technique. A simplified S2 synthetic acceleration is used in the MLTG calculation method to improve the convergence of the source iterations. For the triangularly arranged fuel pins, we adopt a source projection algorithm to generate pin-by-pin source distributions of hexagonal assemblies. MLTG provides accurate geometric modeling and flexible fixed source description at a lower cost than traditional Cartesian grids. The total number of meshes is reduced to 1.9 million from the initial 9.5 million for the Balakovo-3 model. The numerical comparisons show that the MLTG results are in satisfactory agreement with the conventional SN method and experimental data, within the root-mean-square errors of about 4% and 10%, respectively. Compared to uniform fine meshing, approximately 70% of the computational cost can be saved using the MLTG algorithm for the Balakovo-3 computational model.

Healthcare Utilization and Expenditure Depending on the Types of Private Health Insurance in Korea (민간의료보험 가입 및 가입유형별 의료이용 특성 분석)

  • Lee, Jung Chan;Park, Jae San;Kim, Han Nah;Kim, Kye Hyun
    • Korea Journal of Hospital Management
    • /
    • v.19 no.4
    • /
    • pp.57-68
    • /
    • 2014
  • Since the introduction of National Health Insurance(NHI) in 1977, it has grown rapidly and contributed to extend patient's access to the health care services. However, limited coverage for health care services of NHI has been ongoing challenge and private health insurance(PHI) has been rising as an alternative source of enhancing coverage and saving out-of-pocket(OOP) expenditure for patients. In this study, after controlling for socio-demographic, economic, health related variables, we identified the patients' healthcare utilization and subsequent OOP expenditure depending on their PHI enrollment and their enrollment types(fixed benefit, indemnity, fixed benefit plus indemnity). Data were collected from the 2010 Korean Health Panel. The unit of analysis was a member of household(n=13,324). Of the 13,324 cases, 70.7% of patients held PHI, in detail, fixed benefit(47.0%), indemnity(3.6%), fixed benefit plus indemnity(20.1%). Major findings showd that patients who enrolled in PHI used more outpatient services(outpatient visit, number of physician visit, number of examination) and spent more OOP expenditure than non-PHI patients. There were also differences of healthcare utilization and OOP expenditure among the types of PHI. In addition, PHI patients used more inpatient services(inpatient use, number of hospitalization, LOS), but there was no significant difference between PHI and non-PHI patients with regard to the OOP expenditure. Thus, we could not find any distinct relationship between the types of PHI and patients' tertiary hospital use. Policy-makers should need careful political deliberation for monitoring the effect of PHI on health care utilization and subsequent expenditure not only to improve patients' coverage but also to save their OOP expenditures.

  • PDF

Effect of aspect ratio on solutally buoyancy-driven convection in mercurous chloride $(Hg_2Cl_2)$ crystal growth processes

  • Kim, Geug-Tae;Lee, Kyoung-Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.4
    • /
    • pp.149-156
    • /
    • 2006
  • For an aspect ratio (transport length-to-width) of 5, Pr = 2.89, Le = 0.018, Pe = 2.29, Cv = 1.11, $P_B$=40 Torr, solutally buoyancy-driven convection $(Gr_s=3.03{\times}10^5)$ due to the disparity in the molecular weights of the component A $(Hg_2Cl_2)$ and B (He) is stronger than thermally buoyancy-driven convection $(Cr_t=1.66{\times}10^4)$. The crystal growth rate is decreased exponentially for $2.5\;{\leq}\;Ar\;{\leq}\;5$, with (1) the linear temperature profile and a fixed temperature difference, (2) the imposed thermal profile, a fixed crystal region and varied temperature difference. This is related to the finding that the effects of side walls tend to stabilize convection in the growth reactor. But, with the imposed thermal profile, a fixed source region and varied temperature difference, the rate is increased far $2\;{\leq}\;Ar\;{\leq}\;3$, and remains nearly unchanged for $3\;{\leq}\;Ar\;{\leq}\;5$.