• 제목/요약/키워드: fixed phase alignment

검색결과 11건 처리시간 0.028초

Effect of micro-osteoperforations on external apical root resorption: A randomized controlled trial

  • Shahrin, Azaitun Akma;Ghani, Sarah Haniza Abdul;Norman, Noraina Hafizan
    • 대한치과교정학회지
    • /
    • 제51권2호
    • /
    • pp.86-94
    • /
    • 2021
  • Objective: This study aimed to investigate the effect of micro-osteoperforations (MOPs) on external apical root resorption (EARR) during the initial orthodontic alignment phase of maxillary anterior crowding. Methods: Thirty patients (25 females, 5 males; mean age, 22.66 ± 3.27 years) who presented with moderate crowding of the upper labial segment and underwent extraction-based fixed appliance treatment were recruited. They were randomly allocated to receive adjunctive therapy with MOPs (n = 15) or treatment with fixed appliances only (control group; n = 15). EARR was measured from long-cone periapical radiographs taken at the start and the sixth month of treatment. A correction factor for the enlargement difference was used to calculate EARR. Data were analyzed with descriptive statistics and repeated-measures analysis of variance. Results: The mean root lengths of 168 teeth were measured and showed no statistically significant difference (p > 0.05) after six months of fixed appliance treatment in the MOP (mean difference [MD] = 0.13 mm; 95% confidence interval [CI] = -0.10-0.35) and control group (MD = 0.14 mm; 95% CI = -0.10-0.37). Most of the roots in the MOP and control groups (42.86% and 52.38%, respectively) showed only mild resorption. Less than 8% of the roots in both groups (7.14% in the MOP group and 4.76% in the control group) showed moderate resorption. Conclusions: Acceleration of orthodontic tooth movement with adjunctive MOPs therapy during the alignment phase does not exacerbate EARR in patients with moderate crowding of the upper labial segment in comparison with controls.

분리된 마스트에 설치되는 선체고정 위상 배열 레이더의 기계적 정렬 (Mechanical Alignment of Hull Mounted Phased Array Radar on the Separated Mast)

  • 서형필;김대한;김준우;이경진;조규룡
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.465-473
    • /
    • 2019
  • 본 논문은 4면 선체 고정형 위상 배열 레이더를 부착하기 위한 2개의 분리된 마스트를 해군 함정에 정확하게 탑재하기 위한 기계적 정렬 방법과 정렬을 위한 3D 스캐너를 활용한 계측 방법에 대해 연구하였다. 선체 고정 위상 배열레이더는 초고주파를 사용하므로 짧은 파장으로 인해 작은 위치오차에도 이로 인한 소자의 위상차이가 발생할 수 있고 배열 안테나가 선체 고정식이므로 4개의 배열 면에 대해 회전형 레이더 보다 높은 정도 관리(accuracy control)가 필수적이다. 육상 공장에서 제작된 2개의 레이더용 마스트에 대한 편평도 확인 방법, 마스트들을 함정에 탑재하기 위해 정렬을 하는 방법과 4개의 array 부착용 Pad 가공 면에 대해 정렬하는 방법을 도출하였다. 이에 대한 도구로 3D 레이저 스캐너에 의한 측량과 측량 결과를 3D CAD와 비교하기 위한 소프트웨어 활용의 방법이 사용된다. 이 논문은 한국 해군함정에서 분리된 마스트에 4면 선체 고정 위상 배열 레이더를 설치하고 기계적 정렬 방법을 도출한 최초의 사례로서 의미가 있다.

Multi-channel 5Gb/s/ch SERDES with Emphasis on Integrated Novel Clocking Strategies

  • Zhang, Changchun;Li, Ming;Wang, Zhigong;Yin, Kuiying;Deng, Qing;Guo, Yufeng;Cao, Zhengjun;Liu, Leilei
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.303-317
    • /
    • 2013
  • Two novel clocking strategies for a high-speed multi-channel serializer-deserializer (SERDES) are proposed in this paper. Both of the clocking strategies are based on groups, which facilitate flexibility and expansibility of the SERDES. One clocking strategy is applicable to moderate parallel I/O cases, such as high density, short distance, consistent media, high temperature variation, which is used for the serializer array. Each group within the strategy consists of a full-rate phase-locked loop (PLL), a full-rate delay-locked loop (DLL), and two fixed phase alignment (FPA) techniques. The other is applicable to more awful I/O cases such as higher speed, longer distance, inconsistent media, serious crosstalk, which is used for the deserializer array. Each group within the strategy is composed of a PLL and two DLLs. Moreover, a half-rate version is chosen to realize the desired function of 1:2 deserializer. Based on the proposed clocking strategies, two representative ICs for each group of SERDES are designed and fabricated in a standard $0.18{\mu}m$ CMOS technology. Measurement results indicate that the two SERDES ICs can work properly accompanied with their corresponding clocking strategies.

Ellipsometry에서의 Calibration 및 입사면 고정형 Ellipsometer (Calibration and a Plane of Incidence Fixed Ellipsometer)

  • 경재선;오혜근;안일신;김옥경
    • 반도체디스플레이기술학회지
    • /
    • 제2권4호
    • /
    • pp.23-26
    • /
    • 2003
  • The general users find difficulties in using ellipsometers. Thus, the object of this study is to construct an ellipsometer with simple operation principle. We developed an ellipsometer which does not require alignment and calibration before measuring sample. A basis structure model after rotating a compensator spectroscopic ellipsometry, the fixed incidence angle at $70^{\circ}$. This ellipsometer does not demand calibration, because the plane of incidence is not changed due to the novel sample holder structure. The results for various standard samples were compared with those from conventional RCSE to test the performance of this instrument. Also repeated measurements were performed to test the precision of the calibration coefficient in a plane of incidence fixed.

  • PDF

Modification of conventional X-ray diffractometer for the measurement of phase distribution in a narrow region

  • Park, Yang-Soon;Han, Sun-Ho;Kim, Jong-Goo;Jee, Kwang-Yong;Kim, Won-Ho
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.407-414
    • /
    • 2006
  • An X-ray diffractometer for spatially resolved X-ray diffraction measurements was developed to identify phase in the narrow (micron-scaled) region of high burn-up fuels and some nuclear materials. The micro-XRD was composed of an X-ray microbeam alignment system and a sample micro translation system instead of a normal slit and a fixed sample stage in a commercial XRD. The X-ray microbeam alignment system was fabricated with a microbeam concentrator having two Ni deposited mirrors, a vertical positioner, and a tilt table for the generation of a concentrated microbeam. The sample micro translation system was made with a sample holder and a horizontal translator, allowing movement of a specimen at $5{\mu}m$ steps. The angular intensity profile of the microbeam generated through a concentrator was symmetric and not distorted. The size of the microbeam was $4,000{\times}20{\mu}m$ and the spatial resolution of the beam was $47{\mu}m$ at the sample position. When the diffraction peaks were measured for a $UO_2$ pellet specimen by this system, the reproducibility ($2{\Theta}={\pm}0.01^{\circ}$) of the peaks was as good as a conventional X-ray diffractometer. For the cross section of oxidized titanium metal, not only $TiO_2$ in an outer layer but also TiO near an oxide-metal interface was observed.

Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial

  • Aydin, Burcu;Senisik, Neslihan Ebru;Koskan, Ozgur
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.153-162
    • /
    • 2018
  • Objective: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. Methods: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi ($27^{\circ}C$) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little's Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. Results: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week ${\times}$ diameter ${\times}$ application (p < 0.05). Conclusions: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.

Adverse effect of IL-6 on the in vitro maturation of porcine oocytes

  • Yi, Young-Joo;Adikari, Adikari Arachchige Dilki Indrachapa;Moon, Seung-Tae;Heo, Jung-Min;Lee, Sang-Myeong
    • 농업과학연구
    • /
    • 제48권3호
    • /
    • pp.607-615
    • /
    • 2021
  • Cytokines are protein mediators that possess the ability to assist cell-to-cell communication in immune system-related activities. In general, pathogen endotoxins activate the release of inflammatory mediators, and with time, there is an increase in the cytokine levels in the body. Interleukin (IL)-6 mediates the acute-phase inflammatory response, and elevated IL-6 levels have been reported in peritoneal fluids of women with pelvic inflammation and endometriosis, thereby associating it with oocyte quality and infertility. To overcome subfertility or infertility in humans and animals, the present study was done to examine the effect of recombinant IL-6 on porcine oocytes matured in vitro and subsequently to determine the fertilization rate and embryo development. Porcine oocytes were incubated with varying concentrations of IL-6 (0 - 2 ㎍·mL-1) for 44 h followed by in vitro fertilization and culturing of the oocytes. The oocytes or embryos were fixed with 3.7% paraformaldehyde (PFA) and stained with fluorescence dyes, and the meiotic spindle, chromosome organization, fertilization status and embryo development were subsequently assessed under a fluorescence microscope. We observed induction of an abnormal meiotic spindle alignment in the oocytes incubated with IL-6 compared to the control oocytes incubated without IL-6. Moreover, significantly decreased fertilization rates and embryo development were observed for oocytes incubated with IL-6 (p < 0.05). Thus, an increased IL-6 level during oocyte maturation could be associated with fertilization failure due to an aberrant chromosomal alignment and a disruption of the cortical granules. Taken together, our results indicate that successful assisted reproduction can be achieved by controlling the levels of inflammatory cytokines.

Maxillary protraction using customized mini-plates for anchorage in an adolescent girl with skeletal Class III malocclusion

  • Liang, Shuran;Xie, Xianju;Wang, Fan;Chang, Qiao;Wang, Hongmei;Bai, Yuxing
    • 대한치과교정학회지
    • /
    • 제50권5호
    • /
    • pp.346-355
    • /
    • 2020
  • The treatment of skeletal Class III malocclusion in adolescents is challenging. Maxillary protraction, particularly that using bone anchorage, has been proven to be an effective method for the stimulation of maxillary growth. However, the conventional procedure, which involves the surgical implantation of mini-plates, is traumatic and associated with a high risk. Three-dimensional (3D) digital technology offers the possibility of individualized treatment. Customized mini-plates can be designed according to the shape of the maxillary surface and the positions of the roots on cone-beam computed tomography scans; this reduces both the surgical risk and patient trauma. Here we report a case involving a 12-year-old adolescent girl with skeletal Class III malocclusion and midface deficiency that was treated in two phases. In phase 1, rapid maxillary expansion and protraction were performed using 3D-printed mini-plates for anchorage. The mini-plates exhibited better adaptation to the bone contour, and titanium screw implantation was safer because of the customized design. The orthopedic force applied to each mini-plate was approximately 400-500 g, and the plates remained stable during the maxillary protraction process, which exhibited efficacious orthopedic effects and significantly improved the facial profile and esthetics. In phase 2, fixed appliances were used for alignment and leveling of the maxillary and mandibular dentitions. The complete two-phase treatment lasted for 24 months. After 48 months of retention, the treatment outcomes remained stable.

Orthodontic treatment in a patient with Moebius syndrome: A case report

  • Lee, Sanghee;Moon, Cheol-Hyun
    • 대한치과교정학회지
    • /
    • 제52권6호
    • /
    • pp.451-460
    • /
    • 2022
  • Moebius syndrome (MBS) is a congenital neurologic disorder that causes cranio-facial abnormalities. It involves paralysis of the VI and VII cranial nerves and causes bilateral or unilateral facial paralysis, eye movement disorder, and deformation of the upper and lower limbs. The orofacial dysfunctions include microstomia, micrognathia, hypotonic mimetic and lip muscles, dental enamel hypoplasia, tongue deformity, open bite or deep overbite, maxillary hypoplasia, high arched palate, mandibular hyperplasia or features indicating mandibular hypoplasia. This case report presents a 7-year-old male patient who was diagnosed with MBS at the age 2 years. The patient displayed typical clinical symptoms and was diagnosed with Class II malocclusion with a large overjet/overbite, tongue deformity and motion limitation, and lip closure incompetency. Treatment was initiated using a removable appliance for left scissor bite correction. After permanent tooth eruption, fixed appliance treatment was performed for correction of the arch width discrepancy and deep overbite. A self-ligation system and wide-width arch form wire were used during the treatment to expand the arch width. After 30 months of phase II treatment, the alignment of the dental arch and stable molar occlusion was achieved. Function and occlusion remained stable with a Class I canine and molar relationship, and a normal overjet/overbite was maintained after 9.4 years of retainer use. In MBS patients, it is important to achieve an accurate early diagnosis, and implement a multidisciplinary treatment approach and long-term retention and follow-up.

Effectiveness of anchorage with temporary anchorage devices during anterior maxillary tooth retraction: A randomized clinical trial

  • Barthelemi, Stephane;Desoutter, Alban;Souare, Fatoumata;Cuisinier, Frederic
    • 대한치과교정학회지
    • /
    • 제49권5호
    • /
    • pp.279-285
    • /
    • 2019
  • Objective: This study evaluated the efficiency of anchorage provided by temporary anchorage devices (TADs) in maxillary bicuspid extraction cases during retraction of the anterior teeth using a fixed appliance. Methods: Patients aged 12 to 50 years with malocclusion for which bilateral first or second maxillary bicuspid extractions were indicated were included in the study and randomly allocated to the TAD or control groups. Retraction of the anterior teeth was achieved using skeletal anchorage in the TAD group and conventional dental anchorage in the control group. A computed tomography (CT) scan was performed after alignment of teeth, and a second CT scan was performed at the end of extraction space closure in both groups. A three-dimensional superimposition was performed to visualize and quantify the maxillary first molar movement during the retraction phase, which was the primary outcome, and the stability of TAD movement, which served as the secondary outcome. Results: Thirty-four patients (17 in each group) underwent the final analysis. The two groups showed a significant difference in the movement of the first maxillary molars, with less significant anchorage loss in the TAD group than that in the control group. In addition, TAD movement showed only a slight mesial movement on the labial side. On the palatal side, the mesial TAD movement was greater. Conclusions: In comparison with conventional dental anchorage, TADs can be considered an efficient source of anchorage during retraction of maxillary anterior teeth. TADs remain stable when correctly placed in the bone during the anterior tooth retraction phase.