• Title/Summary/Keyword: fit testing

Search Result 336, Processing Time 0.023 seconds

CONSIDERATION OF IR PHASE-SHIFTING INTERFEROMETRIC SYSTEM FOR TESTING ASTRONOMICAL ASPHERIC MIRROR IN CHINA

  • ZHOU WENGE;CUI XIANGQUN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.403-404
    • /
    • 1996
  • This paper describes a plan of a new IR phace-shfting interferometric system for testing astronomical aspheric mirror which has big departure from the best fit reference sphere during fine grinding. In this experimental system, some new technology will be adopted. The accuracy of system can reach $\lambda$/40($\lambda$=10.6${\mu}m$)

  • PDF

Introduction to Electromagnetic Nondestructive Testing (전자기 비파괴검사의 소개)

  • Shin, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.122-124
    • /
    • 1994
  • The purpose of this paper is to attract electrical and electronic engineering community's attention to electromagnetic nondestructive testing (NDT). Various electromagnetic NDT methods of detecting defects in materials are presented to help understand the underlying physics associated with these techniques. This understanding would provide a way to interpret the test signal to describe about the defect. In the meantime, the author hopes, one may realize how perfectly fit such a subject as electromagnetic NDT is to current curriculums of electrical and electronic engineering.

  • PDF

Review on the Development of 3-Dimensional Face Recognition and Measurement for the Design of Respirators (호흡보호구 디자인을 위한 삼차원 얼굴인식 및 측정에 관한 고찰)

  • Kim, Hyunwook;Kim, Kangyoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.92-101
    • /
    • 2001
  • This article reviewed previous studies on the 3D face recognition and anthropometric facial analysis to design suitable respirators for individuals. 3D facial anthropometric data have not been reported in Korea yet. With 3D facial data, it is possible to design and to manufacture respirators having more effective respirator-face seal and thus providing more comfortable wearing than donning of those respirators designed using 1 and 2-dimensional data. Also 3D data could be used for respirator fit-testing and selecting suitable respirator type and size by computer simulation without several steps of fit-test to each individual worker.

  • PDF

Testing Goodness of Fit of Gravity Models (중력모형의 적합도 검증)

  • 김형진
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • This paper is concerned with assessing goodness of fit of gravity models. The Chi-square test, or one of its asymptotic equivalents, is usually recommended for the purpose. A difficulty that frequently arises, particularly when working with urban travel data, is that the expected number of trips for most origin-destination(O-D) pairs are small. In order to test goodness of fit of gravity model, a simple approach, which depends on the number of O-D pairs and certain trip totals being large, is proposed in this paper. In addition, derivation of variance of Chi-square ratio is proposed to test the confidence interval of Chi-square ratio and application of its results with simulated data set is made to verify the usefulness of the results.

  • PDF

A Nonparametric Goodness-of-Fit Test for Sparse Multinomial Data

  • Baek, Jang-Sun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.2
    • /
    • pp.303-311
    • /
    • 2003
  • We consider the problem of testing cell probabilities in sparse multinomial data. Aerts, et al.(2000) presented $T_1=\sum\limits_{i=1}^k(\hat{p}_i-p_i)^2$ as a test statistic with the local polynomial estimator $(\hat{p}_i$, and showed its asymptotic distribution. When there are cell probabilities with relatively much different sizes, the same contribution of the difference between the estimator and the hypothetical probability at each cell in their test statistic would not be proper to measure the total goodness-of-fit. We consider a Pearson type of goodness-of-fit test statistic, $T=\sum\limits_{i=1}^k(\hat{p}_i-p_i)^2/p_i$ instead, and show it follows an asymptotic normal distribution.

  • PDF

Goodness-of-Fit Test for the Normality based on the Generalized Lorenz Curve

  • Cho, Youngseuk;Lee, Kyeongjun
    • Communications for Statistical Applications and Methods
    • /
    • v.21 no.4
    • /
    • pp.309-316
    • /
    • 2014
  • Testing normality is very important because the most common assumption is normality in statistical analysis. We propose a new plot and test statistic to goodness-of-fit test for normality based on the generalized Lorenz curve. We compare the new plot with the Q-Q plot. We also compare the new test statistic with the Kolmogorov-Smirnov (KS), Cramer-von Mises (CVM), Anderson-Darling (AD), Shapiro-Francia (SF), and Shapiro-Wilks (W) test statistic in terms of the power of the test through by Monte Carlo method. As a result, new plot is clearly classified normality and non-normality than Q-Q plot; in addition, the new test statistic is more powerful than the other test statistics for asymmetrical distribution. We check the proposed test statistic and plot using Hodgkin's disease data.

A Smooth Goodness-of-fit Test Using Selected Sample Quantiles

  • Umbach, Dale;Masoom Ali, M.
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.3
    • /
    • pp.347-358
    • /
    • 1996
  • A new test for goodness-of-fit is presented. It is a modification of a test of LaRiccia (1991). These tests are applicable to continuous lo-cation/scale models. The new test statistic is based on a few selected order statistics taken from the sample, while the LaRiccia test is based directly on the full sample. Each test embeds the hypothesized model in a larger linear model and proceeds to test the goodness-of-fit hy-pothesis by testing the coefficients of this linear model appropriately. The general theory is presented. The tests are compared via computer simulation to a related test of Ali and Umbach (1989) for distributions that could be used as lifetime models. An important aspect of all these tests is that only standard $X_2$ tables are used. Selection of the spacings of the order statistics is discussed.

  • PDF

Vibration Analysis of Rotating System in a Turbine and Generator Set: Comparison of Shrunk-fit Disc Rotor and Welded Drum Rotor (터빈발전기의 축계 진동 해석: 열박음형과 용접형 로터의 진동 특성 비교)

  • Ha, Hyun-Cheon;Park, Chul-Hyun;Choi, Seong-Pil;Kim, Kay-Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.599-604
    • /
    • 2000
  • Excessive vibration magnitude results in serious damage and economic losses in the turbine and generator system. Therefore, it is of importance to evaluate the accurate dynamic characteristics of the system in advance. In this paper, rotordynamic characteristics of both the shrunk-fit disc and welded drum rotors have been investigated to ensure an excellent running behavior of the system in which low-pressure(LP) turbines of a nuclear power plant were retrofitted to improve thermal efficiency and reliability. Analysis shows that the welded drum rotor has good torsional characteristics rather than the shrunk-fit disc rotor. In addition, verification testing of field test was performed to confirm the retrofit. Test results are good agreement with analysis ones.

  • PDF

A Study on Software Reliability Growth Model for Isolated Testing-Domain under Imperfect Debugging (불완전수정에서 격리된 시험영역에 대한 소프트웨어 신뢰도 성장모형 연구)

  • Nam, Kyung-H.;Kim, Do-Hoon
    • Journal of Korean Society for Quality Management
    • /
    • v.34 no.3
    • /
    • pp.73-78
    • /
    • 2006
  • In this paper, we propose a software reliability growth model based on the testing domain in the software system, which is isolated by the executed test cases in software testing. In particular, our model assumes an imperfect debugging environment in which new faults are introduced in the fault-correction process, and is formulated as a nonhomogeneous Poisson process(NHPP). Further, it is applied to fault-detection data, the results of software reliability assessment are shown, and comparison of goodness-of-fit with the existing software reliability growth model is performed.

Effects of Wearing between Respirators and Glasses Simultaneously on Physical and Visual Discomforts and Quantitative Fit Factors (안면부 여과식 방진마스크와 안경 동시 착용 시 불편감과 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.52-60
    • /
    • 2018
  • This study compares the differences of the fit factor by the order of wearing preference between Particulate filtering facepiece respirators(PFFR) and glasses when participants wore simultaneously and a survey of physical and visual complaint. Recognition level about fit of respirators was investigated and the educational (before- and after-) effect of the fit factor. When participants wore PFFR and glasses, physical complaints were nose pressure, slipping, nose and ear pressure, ear pressure and rim loosen, the most highly physical complaints were nose pressure. Visual complaints were demister, blurry vision, dizziness, visual field, and lens dirty, the most highly visual complaints were demister. But, there was significant difference in physical complaint such as nose pressure(10.3%), slipping (23.0%), nose and ear pressure(14.3%), and rim loosen(16.2%), visual complaint such as visual field(13.8%) and lens dirty(32.4%). For the recognition of fit of respirators, respirators fitness, leak site, an initial point and an object, faulty factor, recognition level was higher. Fit factor was increased after education of proper wearing of respirator. Change of the fit factor was smaller compared to the normal breathing and after 6 actions in case of after education. Questionnaire consisted of general characteristics and physical/visual complaint, recognition of fit. Complaints were measured after the QNFT with multiple choices. Quantitative fit factor was measured by device and compared the result of (before- and after-) educational effect. Also, we selected to 6 actions (Normal breathing, Deep breathing, Bending over, Turning head side to side, Moving head up and down, Normal breathing) among 8 actions OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The fit factor was higher after the training (p=0.000). Descriptive statistics, paired t-test, and Wilcoxon analysis were performed to describe the result of questionnaire and fit test. (P=0.05) Therefore, it is necessary to investigate the quantitative research such as training program and glasses fitting factor about the wearing of PFFR and glasses simultaneously.