Experimental Study on the Flexural Capacity of AU Composite Beam After the Heating Test (가열 시험을 거친 AU 합성보의 휨 성능에 관한 실험 연구)

  • Kim, Young Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2019
  • AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. Fire safety for the practical application of the composite beam has also been verified through the fire resistance tests and the heat transfer analyses. In this study 2-points bending tests were performed on the four specimens already tested for fire resistance to evaluate the residual bending strength of AU composite beam after fire accident. The same bending test was performed on the one fresh specimen having the same section and span of the specimens for practically comparative study.

Development and Application of CFT without Fire Protection using High Performance Steel and Concrete

  • Hong, Seok-Beom;Kim, Woo-Jae;Park, Hee-Gon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.272-281
    • /
    • 2013
  • Concrete filled tube (CFT) columns, which consist of a steel tube filled with concrete, combine the benefits of the two materials. The steel tube provides a confining pressure to the concrete, while the local buckling of steel plate can be prevented by the concrete core. CFT columns also have a high fire resistance due to the heat storage effect of concrete under fire. For this reason, it is possible to develop CFT columns without fire protection measures. CFT columns without fire protection have many advantages, including quality control, cost reduction, better space efficiency and a shorter construction period. Due to these advantages, studies on the development of CFT columns without fire protection measures have been performed. However, CFT columns lose their bearing capacity under fire because the steel tube is exposed to the outside. As a result, the structure is collapsed, causing significant damage. In this research, we made a CFT column using high strength concrete (100 MPa) and high strength steel (800 MPa). We use steel fiber and nylon fiber with concrete to provide fire resistance. We perform the fresh concrete experiment and investigate the fire resistance of the CFT column (${\Box}400{\times}400{\times}15{\times}3000mm$) under loading. To investigate the effect of steel fiber on increasing fire resistance, we compare the fire resistance time according to the steel fiber. Through the test, it was found that the CFT specimen with steel fiber had better fire resistance performance than other cases.

Compressive Behaviour of Geopolymer Concrete-Filled Steel Columns at Ambient and Elevated Temperatures

  • Tao, Zhong;Cao, Yi-Fang;Pan, Zhu;Hassan, Md Kamrul
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.327-342
    • /
    • 2018
  • Geopolymer concrete (GPC), which is recognised as an environmentally friendly alternative to ordinary Portland cement (OPC) concrete, has been reported to possess high fire resistance. However, very limited research has been conducted to investigate the behaviour of geopolymer concrete-filled steel tubular (GCFST) columns at either ambient or elevated temperatures. This paper presents the compressive test results of a total of 15 circular concrete-filled steel tubular (CFST) stub columns, including 5 specimens tested at room temperature, 5 specimens tested at elevated temperatures and the remaining 5 specimens tested for residual strength after exposure to elevated temperatures. The main variables in the test program include: (a) concrete type; (b) concrete strength; and (c) curing condition of geopolymer concrete. The test results demonstrate that GCFST columns have similar ambient temperature behaviour compared with the conventional CFST counterparts. However, GCFST columns exhibit better fire resistance than the conventional CFST columns. Meanwhile, it is found that the GCFST column made with heat cured GPC has lower strength loss than other columns after exposure to elevated temperatures. The research results highlight the possibility of using geopolymer concrete to improve the fire resistance of CFST columns.

Fire Resistance Performance of High Strength-Light Weight Concrete (고강도를 적용한 1종 경량골재 콘크리트의 내화특성)

  • Song, Hun;Lee, Jong-Chan;Lee, Sea-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.749-752
    • /
    • 2005
  • Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Thus, this study is concerned with experimentally investigating fire resistance of high strength-light weight concrete. From the test result, high strength-light weight concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

  • PDF

An Analytic Study on Structural Stability according to Boundary Conditions and H-section Column Lengths Made of An Ordinary Grade Structural Steels (SS 400) at High Temperatures (일반구조용 강재(SS 400)기둥부재의 경계조건과 부재 길이변화에 따른 고온 내력의 해석적 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • Steel column is very important an structural element in steel framed building and plays a key role in sustataining the applied external load. Generally, the fire resistance performance of steel column has been executed by application of fire standard and vertical furnace having a limitation in height. Therefore, the fire resistance test was conducted with a H-section column having 3500 mm in length and hinge to hinge boundary condition. And the fire protective material derived from the fire test can be applied to any kind of boundary conditions and lengths. However, it is hard to determine the fire resistance. In this paper, to make sure the structural stability of them at high temperature according to various boundary conditions and lengths of H-section column, an analysis was done by using the mechanical properties and an heat transfer theory.

Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing (공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.115-123
    • /
    • 2022
  • Statistics on the occurrence of fires in residential facilities over the past 10 years, show that approximately 40% are fires in apartment buildings. To prevent the spread of fire and support evacuation in apartment housing, the fire resistance performance and performance design of fire doors are becoming more important. This study established a database using 395 quality inspection reports from 2016 to 2020, which passed the fire performance test, and derived the fire door performance-influencing factors through an analysis of the structure (12 elements) of the fire door. As a result, the effect of core material, adhesive, hinge type, blowing agent, etc. was confirmed in 287 pass cases. On the other hand, it was confirmed that the occurrence of flames and crevices in the 108 cases of failure were the major failure factors in the fire door fire resistance test. Fire doors are composed of composite materials to prevent failure of fire resistance performance, and efficient design and quality control are required through standardization of components.

Experimental Study on the Fire Resistance of the iTECH Composite Beam (iTECH 합성보의 내화성능에 대한 실험연구)

  • Lee, Sueng Jae;Kang, Seong Deok;Choi, Seng Kwan;Kim, Myeong-Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.643-654
    • /
    • 2006
  • Thispaper presents the results of an experimental investigation into the fire performances ofsimply supported iTECH composite beams using an ISO834 standard fire. There are very few independent studies on the fire resistance of composite steel and concrete structures of various designs. The iTECH composite beam system has been used in construction, but nothing is known about its influence in a fire. To evaluate the fire resistance performanceof the iTECH beam, a test was conducted for 4.7m-span-length iTECH beams under given conditions in a laboratory. The fire resistance performance of unprotected coatings of the iTECH beam has been examined, and a longer period of fire resistance was achieved by increasing the beam coating's section size and decreasing its load ratio. Coatings for the fire protection of iTECH beams reduce the rate of temperature rise of the beam in case of fire, and the required thickness of spray-on fire protection coatings can be determined by means of tests.

An Experimental Study on the Fire Resistance Properties of High Strength Concrete using Fiber for Field Application (현장 적용을 위한 섬유혼입 고강도콘크리트의 내화특성에 관한 실험적 연구)

  • Kim, Yong-Ro;Song, Young-Chan;Jungi, Yang-Hee;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.187-191
    • /
    • 2008
  • It is necessary to develop a technology for effectively controling explosive spalling of high strength concrete caused increasing construction of high rise building and putting up the fireproof standard of high strength concrete by MLTM (Ministry of Land, Transport and Maritime Affairs). Accordingly, it was investigated basic properties such as slump, air content and compressive strength, and fire resistance properties of high strength concrete using polypropylene fiber for field application as a countermeasure for explosive spalling of concrete on fire in this study, As a test result, it was confirmed that PP fiber is available as fire resistance method of high strength concrete.

  • PDF

A Study on the Corrosion Resistance Test of Smoke Detectors (연기감지기의 내식시험에 관한 연구)

  • Kim, Hyeong-Gweon;Yoon, Hun-Ju;Kwon, Seong-Pil;SaKong, Seong-Ho;Back, Chang-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF

The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST) (절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가)

  • Lee, Jang-Woo;Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.