• Title/Summary/Keyword: fire scene

Search Result 139, Processing Time 0.025 seconds

Development Considerations of Natural Disaster Command System for Public Officers through Analysis of Disaster Response Activities at On-Scene (풍수해 현장대응업무 분석을 통한 재난현장 일반직 공무원 대응편제 개발시 고려사항 연구)

  • We, Kum Sook;Jeong, An Young
    • Journal of Korean Society of Disaster and Security
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 2013
  • Standard Incident Command System in Korea is that Incident Command System for Emergency Rescue Operation, which is commanded only by Fire Fighting Agencies. However, in the event of a disaster such as the flood, storm, or landslide disaster, there are many disaster response activities performed by the General Public Officers at the disaster on-scene. Yet, there isn't an Natural Disaster Command System for the General Public Officers in Korea. Thus, we have studied the response activities needed cooperation among agencies and proposed some considerations of the Natural Disaster Command System for General Public Officers. The system will be useful to response and recover disaster rapidly, seamlessly, and cooperatively among General Public Officers and the related agencies.

Triage Score as a Predictor of need for Tertiary care Center Transport from Scene by Helicopter (소방헬기를 이용하여 직접 내원한 외상환자의 분석: 3차 의료기관으로의 이송의 적절성 평가)

  • Song, Song Won;Yoon, Jae Chol;Lee, Boo Soo;Kim, Woo Joo;Ahn, Ji Yoon;Oh, Bum Jin;Lim, Kyung Su
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.159-163
    • /
    • 2006
  • Purpose: The number of patients transported by the Helicopter Emergency Medical Service (HEMS) has increased recently. In our review of the Korean HEMS, there was no established helicopter utilization criteria or triage tool on the scene, so many patients with minor injuries were transported to tertiary care centers. The aim of this study is to evaluate the percentage of patients with minor injuries and to propose a more appropriate triage tool for predicting the need for transport to a tertiary care center. Methods: The subjects of this study were 59 trauma patients transported to Asan Medical Center (AMC) from the scene by Seoul HEMS from January 2004 to December 2005. The Triage score (TS), Injury Severity Score (ISS), and modified Canadian Triage and Acuity Scale (mCTAS) were calculated as severity scales. Patients with minor injuries were defined as those with TS=9, ISS${\leq}15$, and mCTAS${\geq}3$. We evaluated the association of TS, ISS, and mCTAS with the appropriateness of transport. Results: Many of the patients transported to tertiary medical centers were classified as having a minor injury: TS=9 group 35 cases (72.9%), ISS${\leq}15$ group 30 cases (62.5%) and mCTAS${\geq}3$ group 27 cases (56.2%). However, 56.2% (27/59) of the patients were appropriately transported according to need for admission or an operation. The more severely injured patients classified by TS, ISS, and mCTAS were more appropriately transported to a tertiary center (p<0.05). Conclusion: Many patients with minor injuries were transported to a tertiary center from the scene directly. The TS can be easily calculated by an emergency medical technician at the scene. Thus, we propose the TS as a useful triage tool for determining the necessity of transport to a tertiary center by helicopter.

A Study on The Awareness of Fire-Fighting Officer for Strengthening Capabilities of Disaster Response System (재난현장 대응체계 역량강화를 위한 소방공무원 의식조사 연구)

  • Woo, Jaebong;Shin, Hojoon;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.276-281
    • /
    • 2013
  • This thesis grasped problems by examining the current status of disaster response system repeated during the disaster according to the changes of social environment and suggested current status of disaster response system and developmental measures through the investigation of the awareness of fire-fighting officer. On disaster site, close cooperation system of disaster safety measure headquarter and urgent rescue controlling association must be formed and range and time of the action must be accurately improved so as not to cause duplication of rights for orders. Also, systematic education and training system must be established so as to strengthen disaster site reaction capability and manpower and equipment for it must be increased. Finally, detailed measures for improving initial reaction capability during the disaster, such as tactic development, reaction plan establishment, etc, are requested.

A Comparative Study of the Security Prevention Strategies on Arson: Focused on the Behavioral Characteristics between Serial Arsonists and Simple Arsonists (방화범죄의 경비예방 전략에 관한 비교연구 - 연쇄방화범과 단순방화범의 행위적 특성을 중심으로 -)

  • You, Wan-Seok;Hwang, Sung-Hyun
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.139-162
    • /
    • 2011
  • The purpose of this study is to compare with the general and behavioral characteristics between simple and serial arsonists using the data derived from Scientific Crime Analysis System, Criminal Filing Search System, and Crime Information Management System. The analysis and findings reported here are derived from data extracted from 160 arsonists arrested by police officer. The independent variables included such socio-economic characteristic as arsonists' gender, age, occupation, education level, and previous criminal records of arsonists, and finally the general characteristics of the scene of fire settings. The dependent variable is whether or not serial fire setter. To achieve the purpose, the analysis of frequencies and cross-tab were conducted. According to frequence and cross-tab analysis, there are great differences of the general and behavior characteristics between two groups. In the comparison of simple and serial arsonists, serial arsonists are more likely to have previous criminal records, low socio-economic status, unmarried and no cohabitants than simple arsonists. furthermore, serial arsonists are more likely to use garbage papers for fire setting in the scene of the crime, to have mental or psychological problems, and to get involved in fire setting for the psychological pleasure than simple arsonists do. The present research has some obvious limitations. First, the analysis is based only on arsonists arrested by police officers. These may be considerable differences in arsonists arrested by police officers and fire setters not arrested by them. Additional research is needed to assess the extent to which these findings would apply to fire setters not arrested by police officer in Korea. Secondly, the data in this study are cross-sectional and simple cross-tab analysis are used. Potential limitation of cross-sectional data concerns the inability to specify the changes in measures as arsonists behavioral characteristics. Therefore, further studies need to use longitudinal data and more complicate statistical techniques such as correlation analysis, multiple regression analysis, or LISREL models to specify the casual relationships between dependent and independent variables for fire settings. Even if this study has some limitations, it is meaningful in which it first investigated the comparison of simple and serial arsonists focusing on the general and behavioral characteristics between two groups in Korea.

  • PDF

The Regional Characteristics of 119 Ambulance Dispatch, the Distance and Response Time to the Scene (119 구급서비스 지역별 출동특성 및 출동거리와 현장도착시간과의 관계)

  • Lee, Kyoung-youl;Moon, Jun-dong;Choi, Eun-sook
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.482-492
    • /
    • 2016
  • Purpose This study is to investigate regional characteristics of 119 ambulance dispatch and the relationship between the distance and response time to the scene. Methods This study was retrospectively conducted 119 running sheets with 1,321 patients who had been transferred to the hospital by 119 ambulance during ambulance attendant training. The training was performed at two, five and three fire station in Seoul, Daejeon and Chungnam respectively, from June 24, 2013 to July 19, 2014. Results Almost the emergency medical services provided were no more than basic first aid in all regions. The patients transferred by 119 ambulance in Seoul were more than other region. The time of call to scene and scene to hospital were the slowest in Chungnam. The major reason of call 119 was due to disease in Seoul and Daejeon, however due to injury in Chungnam. Conclusion Our study suggests that learning from ambulance attendant training course could diverse from region to region. It is, therefore, needed that standardization of ambulance attendant training course, appropriate logistics and resource allocation for providing universal quality of emergency medical services.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

A Study on the Public-Private Partnership in the Emergency Medical System in Korea (한국응급의료서비스 민관파트너십 도입의 타당성에 관한 연구)

  • Kim, Kook-Rae;Kim, Tae-Yun
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.31-43
    • /
    • 2006
  • In Korea, the Emergency Medical Service, EMS is provided by Fire Services with 119 EMS and all the public uses the service for free. Although it appears very successful and is respected nationally, structural problem EMS exist and are worsening. First of all, the "free riding effect" becomes increasingly problematic. Some argue that 30% of the demands is not urgent or emergent. The total number of demands is increasing even without the free riding effect. The Current EMS system itself cannot meet the increasing EMS demand. The medical aspect is so poor that the EMS cannot dispatch a medical specialist to the scene. The cardiac arrest resuscitation rate is only $1.24{\sim}9.9%$, compared to 40% in Boston, MA, USA. But due to the regulations and limitations of the Fire Service organization, it is difficult to secure enough EMS resources. To work out these problems, it needs a structural innovation. To secure enough resources and achieve higher medical performance we should invite the medical sector and the private sector into EMS arena by contracting partnerships with Fire Services and charging a reasonable EMS fee. We found through statistical test that any partnership system is more effective than fire-alone system and most countries around the world have partnership system rather than fire-alone system.

The Problems of the Emergency Rescue and First-aid and the Plan of Improvement in Korea (우리나라 긴급구조$\cdot$구급체계의 문제점과 개선방안)

  • Jung Gi-Sung
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.81-92
    • /
    • 2005
  • It is natural that The government should be responsibility for the fulfillment of obligation to prevent a notional life, accurate rescue and first-aid from various calamities. Although, The government policy is established a foundation that is reventing a national life and a property from the calamity with deciding of the fire line, that is not satisfied with taking precautions against a calamity. In case of the calamity there is always pointed the confrontation procedures, especially, In case of crisis The government is lacking to come to an developed country on account of system of the emergency rescue and first-aid. The prevention and provision are the most important thing with reference to a confrontation of the calamity. But calamity is happened without warning, so We should establish line of prompt rescue and first-aid lately that is very important thing. The First, We should get the single line of the rescue and first-aid through a integration and elimination in terms of a law of the emergency rescue and first-aid, but also we strengthen a line of a scene confrontation ability and speciality. To raise awareness of improving a rescue and ability of first-aid, through reinforcing the human and material equipment of The 119 rescue party to charge of emergency rescue and first-aid in effect.

Inspection Robot System using Remote Sensing Images of Fire Scene (원격 탐사 영상을 이용한 화재 현장 탐사 로봇 시스템)

  • Park, Senog Joon;Youn, Hee Yong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.01a
    • /
    • pp.171-173
    • /
    • 2015
  • 최근 원격 탐사를 이용한 사람이 탐사하기 어려운 환경을 대신 탐사 할 수 있는 로봇의 필요성이 두각 되고 있다. 그 중에 화재현장 탐사 로봇은 일부 지형의 협소함 탓에 사람의 탐사를 대신하기 위한 목적으로 지속적인 개발이 이루어지고 있다. 이 로봇은 아두이노(Arduino) 보드를 기반으로 하여 현장에 있는 탐사로봇으로 지형에 대한 정보 및 영상을 사용자에게 전송함으로써 사람의 탐사현장 투입을 대체한다. 탐사로봇은 거리가 멀어질수록 혹은 장애물이 많은 공간일수록 통신 신호가 약해지거나 이동의 어려움 때문에 성능저하가 우려된다. 또한 센서 및 모터제어와 영상 송출이 각각의 프로그램을 통해 동작하므로 일일이 실행하여 사용에 번거롭다는 문제가 있다. 이러한 문제점들은 통신 거리가 긴 동글(dongle)을 설치하여 통신장애를 해결하고 캐터필러의 사용으로 이동성을 향상하였다. 마지막으로 여러 프로그램을 하나의 프로그램으로 새로 구현하여 편리성을 높였다.

  • PDF

Application of GIS Technology for Developing Emergency Management System on High-Speed Lines

  • Kim, Sang-Ahm;Hong, Seon-Ho;Wang, Jong-Bae
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.3
    • /
    • pp.156-162
    • /
    • 2003
  • Due to almost all tracks of new Kyoungbu high-speed lines(HSL) consisting of bridges and tunnels, HSR operational safety management is very important factor for passenger safety and preventing catastrophic event. Especially, it is important to approach the scene of the accident and assist in saving lives as soon as possible under emergency conditions. Therefore it is essential to prepare access methods and available resources in advance in order to support emergency correspodances promptly and effectively. This paper persents an application of geographical information system(GIS) for developing emergency management system as well as batabase system on tracks and facilities, electric/communication equipment and safety equipment required to support emergencies. The on-site information on the proximity of HSL is expressed on the numerical map, which can be helpful to call external supports such as medical service, local authorities, police offices, fire brigades, and etc. for the emergency situations.