• Title/Summary/Keyword: fire risk

Search Result 1,148, Processing Time 0.024 seconds

A Study on Fire Risk Assessment of the Temple Using Fire Loads (화재하중을 통한 사찰의 화재 위험성 평가에 관한 연구)

  • Kim, Su-Young;Shin, Young-Ju;Park, Young-Ju;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.409-415
    • /
    • 2008
  • In this study, we considered the fire risk assessment of the temple using fire loads and the classification of combustibles. The building construction materials were classified as walls, beam-columns, floorings, ceiling panels and the loading combustibles were classified into fixed materials and movable materials. As a result, we confirmed that the total fire load of the Palsangjeon was $368\;kg/m^2$. The building construction materials accounted for approximately 93.8 percent of the total fire load and the loading combustibles accounted for approximately 6.2 percent.

  • PDF

A Study on the Estimation of Required Fire Resistance Time by Use of Building (건축물의 용도별 필요내화시간 산정에 관한 연구)

  • Kim, Yun-Seong;Han, Ji-Woo;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.115-116
    • /
    • 2020
  • Due to the nature of modern society, buildings are becoming larger and more complex. As a result, the design conditions of the building are changing. However, despite the complexities of buildings, the fire resistance performance is still equalized to one hour without considering fire engineering analysis in Korea, so there is a risk according to actual fire design conditions. Therefore, the purpose of this study is to calculate the required fire resistance time for actual fire through fire mechanics analysis and case study.

  • PDF

A Study on the Fire Alarm System of Vertical Fire Spread Structure by Using FDS (FDS을 이용한 수직 연소확대 구조의 화재경보방식에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.100-107
    • /
    • 2016
  • Today, high-rise buildings expected to meet various needs and improve the quality of frequency of fire and the potential risks are increasing. In particular, the fire spread risk in the vertical direction is increasing. As a result there is a problem with delays in the evacuation time of occupants. To overcome this problem, there is a need to consider the structure of the building and develop a system for the early detection of fire by applying a fire alarm system according to the risk ranking. Therefore, this paper describes the vertical fire spread characteristics of a multistory double-skin and stairs structure with risk. The data were compared with that from the national and international fire alarms as well as with. smoke density, smoke detectors, visibility, and CO concentration using FDS. A fire alarm system for each structure is proposed.

Empirical Application for the Urban Disaster Risk Assessment : Fire, Facility and Escape Cases in Cheongju City (도시 재해위험도 평가 모형 연구 - 화재, 시설, 피난위험도 중심의 청주시 사례 -)

  • Hwang, Hee-Yun;Baek, Ki-Young;Park, Byung-Ho;Lee, Man-Hyung;Hwang, Jae-Hoon;Ryu, Eul-Leal;Kim, Tae-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.2 s.2
    • /
    • pp.123-137
    • /
    • 2001
  • Based on basic characteristics of urban disasters and their data availabilities in Korea, this study provides risk assessment models which are derived from Cheongju examples. In specific, the application models are confined to fire, facility and escape risk survey results in the paper. For the assessment criteria, major independent variables for the categories of fire include both the frequency levels and the amount of damage. And the degree of facility risk assessment is heavily hinged on both the weighted values of key facilities and their weighted rank-sizes. In the same context, the degree of escape risk assessment is hinged on both the weighted values and the amount of the classification of land. From the empirical configuration, this paper presents that the potential figure of fire risk is relatively higher in the built-up areas within the existing Central Business District where accommodates a number of dilapidated housing units and community-supportive facilities. In contrast, the potential figure of facility and escape risk is higher in both old residential areas and the newly-built apartment complex. In short, the CBD and its neighboring residential areas record a high potential figure in terms of total risk, juxtaposing fire, facility and escape risk all together.

  • PDF

Risk Screening of a BTX Plant Using FEDI Method (화재폭발손실지수법을 이용한 BTX 공장의 위험선별)

  • Kim Yong-Ha;Kim In-Tae;Kim In-Won;Kim Ku-Hwoi;Yoon En-Sup
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.20-28
    • /
    • 2005
  • Major petrochemical companies in the USA and the EU map out the strategies step-by-step hazard evaluation for the efficient risk management. They adopted the risk screening methods, such as Dow fire & explosion index, as a preliminary phase to execute detailed evaluation such as QRA (Quantitative Risk Assessment). In this study, The FEDI (Fire & Explosion Damage Index), which a kind of risk screening method proposed by Khan and Abbasi, was applied to the BTX plant in Korea. We showed that the FEDI can be effectively used to classify the hazard potential by comparison of the result from the FEDI and the result from QRA. And we showed that the characteristics and the quantities of chemical are the factors which have a largest effect on fire and explosion by executing relative sensitivity analysis of the FEDI. In conclusion, if the FEDI was applied as a preliminary phase of HAZOP, more efficient hazard evaluation can be possible.

A Research of Risk Assessment for Urethane Fire Based on Fire Toxicity (연소 독성 기반 우레탄 화재의 위험성 평가 연구)

  • Kim, Sung-Soo;Cho, Nam-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • Fire in the risk management subject belongs to high risk disaster which accompanies personnel and materiel loss. So, management of disaster and safety is required to include fire prevention activities, fire risk prediction and investment of safety management expense. Combustion toxicity is required by gas toxicity test (KS F 2271), to minimize human damage. In this study, gas toxicity test were experimented with regard to urethane sample (Depth 5~25 mm) to obtain basic data. Fire effluent exposing to experimental animal were analyzed by FT-IR (Fourier transform infrared spectroscopy). Combustion toxicity index Lethal Fractional Effective Dose ($L_{FED}$) of ISO 13344 was calculated. According to the result of calculating Lethal Concentration 50% ($LC_{50}$) based on $L_{FED}$, $LC_{50}$ of urethane sample containing certain level of fire load is confirmed as $118{\sim}129g/m^3$. Through this study, applicability of this method was confirmed for fire risk assessment. This method can provide information to predict human damage by toxicity combustion gas for securing safety.

Analysis of Discharge Characteristics and Fire Risk of Mobile Phone Batteries according to the Concentration of Salt Water (염수농도에 따른 휴대폰 배터리의 방전특성과 화재 위험성 분석)

  • Woo, Jin-Su;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.66-71
    • /
    • 2020
  • The process of discharging batteries using salt water, when used for the disposal of a lithium-ion (Li-ion) batteries, is likely to cause a fire. However, there is a dearth of studies in the literature on the risk of fire while discharging mobile phone batteries in salt water. In order to investigate the possibility of fire by elucidating the discharge characteristics and the generation of heat, we conducted experiments by varying the concentration of the salt water, number of overlapping batteries, and type of the mobile phone batteries used as experimental specimen. The discharging voltage and the temperature of the batteries were measured, and the fire risk was predicted by analyzing the data. The results of the experiment showed that the higher the salt water concentration, the greater the discharge value of the mobile phone battery and the higher the exothermic temperature. Moreover, the exothermic temperatures of the overlapping batteries were higher than that of the single battery submerged in salt water. The highest exothermic temperature points of the battery occurred at the positive and negative poles.

An Experimental Study on the Fire Risk at Welding·Cutting Process (용접·절단 작업시 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.60-66
    • /
    • 2012
  • In this study, it was evaluated the fire risk during welding cutting tasks. Welding-cutting machines are representatively used at construction sites. Inverter AC/DC TIG welding macnine and inverter air plasma cutting machine were used in experiments. Temperature of spreaded cinders was measured using a thermal camera. Cinder sizes and spread range were measured according to the height and input current. It was also evaluated the fire risk during welding-cutting process, when flammable materials were located around the working area. There were used hay, dust fence, urethane foam, vinyl, paper and oil as flammable materials. Temperature of spreaded cinders was reached at about $450^{\circ}C$. Cinders were spread approximately 4.7 m, when a worker carried out cutting process at 2.5 m height. The possibility of a fire is very high, when flammable materials were located around the working area.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

The Improvement of the Specific Target for Fire Fighting of Fire Safety Grade System (특정소방대상물의 방화관리 등급체계 개선방안)

  • Kwak, Chang-Sik;Woo, Seong-Cheon;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.162-171
    • /
    • 2010
  • According to the development of industry, many aspects of society have been changed and a living environment has been more convenient than before. However, factors of fire risk are increased because of society which is becoming complex. Moreover, a building built in recently is becoming high-rise and intelligent. Then losses of life and property increase continually. Thus, an institutional strategy which can solve this problem is needed. The purpose of this research is to state a problem of specific a building managing strategy and suggests a reformation of the fire safety grade system of a specific building. The suggested ideas are an adoption of fire risk evaluation of a building, tentatively named "Fire Safety Corporation" establishment, reclassification of the fire safety grade system of a specific building, and newly making fire safety managers of ultra-high buildings and underground structures.