A Study on Fire Risk Assessment of the Temple Using Fire Loads

화재하중을 통한 사찰의 화재 위험성 평가에 관한 연구

  • Kim, Su-Young (Professional Graduate School of Disaster Prevention Technology, Kangwon National University) ;
  • Shin, Young-Ju (Professional Graduate School of Disaster Prevention Technology, Kangwon National University) ;
  • Park, Young-Ju (Professional Graduate School of Disaster Prevention Technology, Kangwon National University) ;
  • Lee, Hae-Pyeong (School of Fire & Disaster Prevention, Kangwon National University)
  • 김수영 (강원대학교 방재기술전문대학원) ;
  • 신영주 (강원대학교 방재기술전문대학원) ;
  • 박영주 (강원대학교 방재기술전문대학원) ;
  • 이해평 (강원대학교 소방방재학부)
  • Published : 2008.11.13

Abstract

In this study, we considered the fire risk assessment of the temple using fire loads and the classification of combustibles. The building construction materials were classified as walls, beam-columns, floorings, ceiling panels and the loading combustibles were classified into fixed materials and movable materials. As a result, we confirmed that the total fire load of the Palsangjeon was $368\;kg/m^2$. The building construction materials accounted for approximately 93.8 percent of the total fire load and the loading combustibles accounted for approximately 6.2 percent.

Keywords