• 제목/요약/키워드: fire monitoring

검색결과 396건 처리시간 0.033초

Monitoring of Soil Bacterial Community and Some Inoculated Bacteria After Prescribed Fire in Microcosm

  • Song Hong-Gyu;Kim Ok-Sun;Yoo Jae-Jun;Jeon Sun-Ok;Hong Sun-Hee;Lee Dong-Hun;Ahn Tae-Seok
    • Journal of Microbiology
    • /
    • 제42권4호
    • /
    • pp.285-291
    • /
    • 2004
  • The soil bacterial community and some inoculated bacteria were monitored to assess the microbial responses to prescribed fire in their microcosm. An acridine orange direct count of the bacteria in the unburned control soil were maintained at a relatively stable level $(2.0\~2.7\times10^9\;cells/g^{-1}{\cdot}soil)$ during the 180 day study period. The number of bacteria in the surface soil was decreased by fire, but was restored after 3 months. Inoculation of some bacteria increased the number of inoculated bacteria sev­eral times and these elevated levels lasted several months. The ratios of eubacteria detected by a flu­orescent in situ hybridization (FISH) method to direct bacterial count were in the range of $60\~80\%$ during the study period, with the exception of some lower values at the beginning, but there were no definite differences between the burned and unburned soils or the inoculated and uninoculated soils. In the unburned control soil, the ratios of $\alpha-,\beta-\;and\;\gamma-subgroups$ of the proteobacteria, Cytophaga-Fla­vobacterium and other eubacteria groups to that of the entire eubacteria were 13.7, 31.7, 17.1, 16.8 and $20.8\%,$ respectively, at time 0. The overall change on the patterns of the ratios of the 5 subgroups of eubacteria in the uninoculated burned and inoculated soils were similar to those of the unburned con­trol soil, with the exception of some minor variations during the initial period. The proportions of each group of eubacteria became similar in the different microcosms after 6 months, which may indicate the recovery of the original soil microbial community structure after fire or the inoculation of some bac­teria. The populations of Azotobacter vinelandii, Bacillus megaterium and Pseudomonas fluorescens, which had been inoculated to enhance the microbial activities, and monitored by FISH method, showed similar changes in the microcosms, and maintained high levels for several months.

산불 후 복원방법의 차이가 번식기 조류 군집에 미치는 영향 (Differences in Breeding Bird Communities by Post-fire Restoration Methods)

  • 김진용;이은재;최창용;이우신;임주훈
    • 한국환경생태학회지
    • /
    • 제29권4호
    • /
    • pp.508-515
    • /
    • 2015
  • 산불피해지의 복원과정은 산불 후 장기간에 걸친 천이의 영향으로 조류군집에 많은 변화가 예상되므로 장기적인 조사가 필요하다. 본 연구는 대형 산불 발생 13년 후 복원 방법에 따른 번식기 조류 군집의 차이를 파악하기 위해 강원도 삼척시 검봉산 지역에서 산불 미피해지와 산불 후 자연복원지, 산림시업복원지 등 3개 지역을 대상으로 하였으며, 2013년 봄철 번식기 동안 108개 지점의 정점을 조사하였다. 조사 결과, 평균 종수와 개체수, 종다양도는 모두 자연복원지역이 피해목 벌채 및 식재와 같은 산림시업복원지역에 비해 높게 나타났으며, 미피해지역과 자연복원지역은 유의한 차이를 보이지 않았다. 길드 분석 결과, 수관 탐색 조류(foliage searcher)와 수간 및 나무줄기 천공 조류(timber driller), 일차 수동성 조류(primary cavity nester), 이차 수동성 조류(secondary cavity nester) 모두 산불 후 산림시업복원지역이 다른 두 지역보다 서식 밀도가 낮게 나타났으며, 미피해지역과 자연복원지역은 차이를 보이지 않았다. 따라서 산불 후 개벌 및 조림으로 대표되는 복원 방법은 번식기 조류의 밀도 및 종 다양성 회복을 저해할 수 있으므로, 가능한 인위적인 산림시업 방법을 지양하고 자연복원 방식을 채택하는 것이 효율적인 방법이라 생각된다.

저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구 (A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line)

  • 강경원;윤명오;구선환;송영주
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.136-145
    • /
    • 2011
  • 화재발생 원인 중 가장 많은 부분을 차지하는 것 중 하나가 전기적 요인이며 이 전기적 요인 중 일정 비율 이상을 차지하는 것이 누전 지락사고이다. 이러한 누전 지락사고를 줄이기 위해 최근 국제규격인 IEC 60364-4-41을 반영한 저압전로의 지락보호에 관한 기술지침(KECG 1091-2011)이 개정되었으며 설비의 상시사용 운용 및 고장 결함 등을 회복시켜 신뢰성을 향상시키는 보전방식이 대두되고 있다. 따라서 본 논문에서는 최근 10년간의 화재발생현황을 파악하여 전기화재의 위험성을 분석한 후 일정비율 이상 차지하고 있는 누전 지락사고를 개선시키기 위한 방법으로 KECG 1091-2011의 개정사항을 검토한 다음 누전 지락보호검출의 신뢰성을 향상시키기 위한 예방보전 방식을 적용하여 시간계획보전 방식으로 정기점검제도와 내용연수제도에 대한 문제점을 나열한 후 그 해결방안을 제시하고 상태감시보전 방식으로 누설전류 통합감시 장치와 디지털 누전경보기를 제안하고자 한다.

산불로 인한 임도 배수시설의 콘크리트 강도 변화 (Change in the Concrete Strength of Forest Road Drainage Systems Caused by Forest Fires)

  • 최예준;황진성;황영인;전현준;권형근;이준우
    • 한국산림과학회지
    • /
    • 제112권4호
    • /
    • pp.451-458
    • /
    • 2023
  • 산불이 대형화됨에 따라 산불 예방 및 진화를 위해 임도시설의 중요성이 증가하고 있다. 산불 발생 시 임도가 제 역할을 수행하기 위해서는 적정한 노선 선정과 함께 구조적인 안정성을 확보해야 한다. 그동안의 연구는 산불 발생에 따른 임도의 효과와 노선 배치에 치중되어 있으며, 임도의 안전성 확보를 위한 연구는 수행되지 않은 실정이다. 따라서, 본 연구는 최근 3년간 초대형 산불 발생지 내의 임도 콘크리트 시설물을 대상으로 콘크리트 비파괴검사기법 중 하나인 반발경도법을 이용하여 산불 여부에 따라 그 강도를 비교하였다. 연구 결과, 산불 피해 콘크리트 시설물(15.4 MPa)은 미피해 콘크리트 시설물(18.0 MPa)에 비해 낮은 강도를 나타냈으며(p<0.001), 그 경향은 모든 대상 시설물에서 동일하게 나타났다. 따라서, 임도 시설의 강도 저하로 인한 임도의 2차 피해를 방지하기 위해 임도 시설물의 안전진단 기준이 마련되어야 할 것이다. 또한, 본 연구 결과에 대한 지속적인 모니터링과 실내 실험을 동반한 후속 연구가 진행되어 임도의 안정성을 제고해야 하며, 이를 통해 산불 예방과 진화를 위한 더 나은 전략을 마련할 수 있을 것이라 기대한다.

뿜칠내화피복 작업 자동화시스템을 위한 RTLS 기술 적용에 관한 연구 (A Study on the Application of RTLS Technology for the Automation of Spray-Applied Fire Resistive Covering Work)

  • 김균태
    • 한국건축시공학회지
    • /
    • 제9권5호
    • /
    • pp.79-86
    • /
    • 2009
  • 철골구조에서 뿜칠내화피복재는 화재발생시 철골구조물의 내력이 저하되는 것을 방지하는 중요한 자재이다. 그러나 인력에 의한 작업 등으로 인하여 품질관리가 어렵고, 기능인력의 수급도 용이하지 않으며, 기능인력이 유해한 환경에 노출될 가능성도 높은 실정이다. 일반적으로 이와 같이 품질관리가 어렵고 인체에 유해한 건설작업들은 자동화 장비를 도입함으로써 문제를 어느 정도 완화할 수 있다. 그러나 기존의 건설현장은 환경이 비구조화되어 있기 때문에 장비의 주행이나 작업위치선정 등까지 자동화하기는 매우 어려웠다. 본 연구에서는 뿜칠내화피복 작업을 자동화하기 위한 기초연구로써, 자동화시스템과 첨단기술인 RTLS와의 연계성을 검토하고 내화피복 뿜칠 자동화작업의 시나리오, 시스템 구성요소 등을 제안하였다. 제안된 시스템은 아직 개념단계이므로 많은 제약조건들이 해결되지는 않았으나, 제안된 시스템으로 작업하면 내화피복의 균일한 피복두께를 유지할 수 있으며, 철골 구조물과의 일체성을 확보하며, 내화성능을 향상시킬 수 있을 것으로 기대된다. 또한 내화피복의 품질이 확보됨에 따라, 대형 철골 구조물에 화재가 발생하더라도 일정한 강도를 유지할 수 있어서, 화재의 전이를 방지하는 데에 효과가 있을 것으로 예상된다. 향후에는 첨단 IT인 USN등 첨단 모니터링 기술, BIM기술, 자재의 위치정보 인식기술 등과 연계하여 본 연구를 진행할 예정이다. 이와같은 기술과 본 연구가 연계되면, 국내 건설자동화 수준을 제고시키고, 건설 자원의 효율적 체계적 관리를 통한 비용절감, 공기단축, 정밀시공 등을 구현하는 데에 더욱 기여할 수 있을 것이다.

2003년 5월 러시아지역에서 발생한 산불로 인한 스모크 에어로졸 플룸의 영향 (Impact of the Smoke Aerosol from Russian Forest Fires on the Atmospheric Environment over Korea during May 2003)

  • 이권호;김정은;김영준;김준
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.603-613
    • /
    • 2004
  • Extensive forest fires occurred across the border in Russia. particularly east of Lake Baikal between the Amur and Lena rivers in May 2003. These forest fires released large amounts of particulates and gases into the atmosphere. resulting in adverse effects on regional air quality and the global radiation budget. Smoke pollution from the Russian fires near Lake Baikal was sometimes transported to Korea through Mongolia and eastern China. In this study ground based radiation (visible and UV-B) data measured during May 2003 at Seoul and Kwangju were analyzed to estimate smoke aerosol impacts on solar radiation. Surface criteria air pollutants ($PM_{10}$, CO, $O_3$) data were also obtained from National Institute of Environmental Research (NIER) during smoke aerosol event period (19 May~24 May 2003). Large Aerosol Optical Depth (AOD) 1.0~3.0 was observed during this period due to the influence of the long range transport of smoke aerosol plume from the Russian fires, resulting in short-wavelength direct aerosol radiative forcing of -90~ -200W/$m^2$. These smoke aerosol plume caused decrease in surface UV-B radiation up to 80% and increase in PM_(10) concentration up to 200${\mu}g/m^3$ exceeding the 24 hour ambient air quality standard.

역행렬 알고리즘을 이용한 다파장 라만 라이다 데이터의 고도별 에어로졸 Microphysical Parameter 도출 (Retrieval of Aerosol Microphysical Parameter by Inversion Algorithm using Multi-wavelength Raman Lidar Data)

  • 노영민;김영준
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.97-109
    • /
    • 2007
  • Vertical distribution and optical properties of atmospheric aerosols above the Korean peninsula are quite important to estimate effects of aerosol on atmospheric environment and regional radiative forcing. For the first time in Korea, vertical microphysical properties of atmospheric aerosol obtained by inversion algorithm were analyzed based on optical data of multi-wavelength Raman lidar system developed by the Advanced Environmental Monitoring Research Center (ADEMRC), Gwangju Institute Science and Technology (GIST). Data collected on 14 June 2004 at Gwangju ($35.10^{\circ}N,\;126.53^{\circ}E$) and 27 May 2005 at Anmyeon island ($36.32^{\circ}N,\;126.19^{\circ}E$) were used as raw optical data for inversion algorithm. Siberian forest fire smoke and local originated haze were observed above and within the height of PBL, respectively on 14 June 2004 according to NOAA/Hysplit backstrajectory analysis. The inversion of lidar optical data resulted in particle effective radii around $0.31{\sim}0.33{\mu}m$, single scattering albedo between $0.964{\sim}0.977$ at 532 nm in PBL and effective radii of $0.27{\mu}m$ and single scattering albedo between $0.923{\sim}0.924$ above PBL. In the case on 27 May 2005, biomass burning from east China was a main source of aerosol plume. The inversion results of the data on 27 May 2005 were found to be particle effective radii between $0.23{\sim}0.24{\mu}m$, single scattering albedo around $0.924{\sim}0.929$ at 532 nm. Additionally, the inversion values were well matched with those of Sun/sky radiometer in measurement period.

수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발 (Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network)

  • 양승연;김진태;오환진;이민우
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.83-86
    • /
    • 2015
  • 본 논문에서는 수처리 시설용 광대역 통합망 연계 실시간 계측관리 시스템 UI 개발을 제안한다. 수처리시설용 광대역 통합망을 통해 서버로 수신된 센서 및 영상 데이터를 Web과 연동하기 위한 프로그램을 개발하며, 이와 별도로 독립적으로 운영이 가능한 UI를 개발한다. 전송된 센서 및 영상데이터를 원격 모니터링 하기 위한 웹 서버를 구축하며 센서 데이터, 영상 데이터를 Web기반의 UI를 통해 감시 및 제어가 가능하도록 개발하였다. 제안하는 수처리 시설용 광대역 통합망 연계형 실시간 계측관리 시스템을 통하여 센서를 통한 측정시간, 농도, 수심 계면 등의 현재 상태를 파악할 수 있으며 영상 모니터링을 통하여 실시간으로 수처리 시설의 정상적인 동작여부와 보안 및 화재 등의 인명피해 여부를 확인 할 수 있다. 뿐만 아니라 실시간 계측 관리 시스템을 실시간으로 모니터링 할 수 있는 UI 개발로 인해 실시간으로 정보를 한눈에 볼 수 있다.

상황인식 기반 개인 선박 상태감시시스템 설계 및 구현 (A Design and Implementation of Personal Vessel Monitoring System Based on Context Aware)

  • 신도성;이성로
    • 대한전자공학회논문지SP
    • /
    • 제48권3호
    • /
    • pp.112-118
    • /
    • 2011
  • 선박은 위급상황에 노출될 경우 육상의 교통수단에 비해 해양 환경이라는 제약성 때문에 그 위험성이 더 크다. 따라서 위험 요소를 사전에 발견하고 먼저 조치를 취하는 것이 매우 중요하다. 이 논문에서는 선박에 가해지는 위험 요소를 지속적으로 감시하고 상태를 파악할 수 있는 상태감시시스템을 제안하였으며 이를 위해 선박 내에 화재 센서 모듈, 기울기 센서와 비틀림 센서를 설치하여 선박의 안전 상황을 판가름하는 기초가 되는 센서 데이터를 수집하였다. 획득한 센서 데이터는 역전파 신경망을 설계하여 분석하였으며 분석된 데이터를 토대로 판단한 선박 상태 정보는 승무원의 개인 단말기로 송신되어 이동 상황에서도 선박의 상태를 실시간으로 점검할 수 있다. 상황인식 실험 결과 연출된 화재 상황에서 약 95%의 정확도를 보였고 선체의 충격 위험 요소에 대해서 약 89%의 정확도를 보였다.

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;김유성;송윤호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF