• 제목/요약/키워드: fire loads

검색결과 144건 처리시간 0.03초

우수저류조 유닛의 하중강도에 대한 모의실험 분석 (Simulation on Loading Strength of Rainwater Storage Tank Unit)

  • 이상우;남동군;최종문
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.107-113
    • /
    • 2013
  • The design of rainwater storage system unit to manufacture its reservoir tank was tried, the simulation to predict of their structural strength was carried out. Rainwater storage system unit should be easy to their machinability, transport and assemble. Especially, their structure was able to secure the water storage space, withstand loads and easily response to pollution. Considering these various requirements, they have to Doria-pillar structure of the Roman architectural style because these designs could disperse the loads which are applied to them. Therefore, the six kinds of models possible were proposed. Several boundary conditions were given to each model. Their structural strength was predicted through the simulation on their stress and the displacement distribution to constant load. From the evaluated data, the structure which has a large pillar in the central of unit and four small pillars each corner was the best.

다중 분산부하 전압강하산정 프로그램 연구 (A Study of the Voltage drops computation program on multi-distributed random loads)

  • 강차녕;권세혁;조성필
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 2006
  • 전선에서 전압강하는 열 손실을 의미한다. 이 열은 절연체의 특성을 변화시켜 절연성능을 저하시키게 되고 나아가 누전, 감전, 정전 및 화재 등의 사고를 일으키는 원인이 되기도 한다. 그러므로 전압강하에 대한 최적화 설계는 전기설비의 안전성과 경제성을 보장하는 중요한 요소가 되고 있다. 이에 저압의 전기설비인 가로등, 빌딩, 지하철역사 등 공공의 안전확보가 요구되는 다중 분산부하계통에서의 전압강하가 전기배선에 미치는 영향을 분석하고, 안전성 및 경제성 확보를 위한 전압강하산정 프로그램 및 최적화 방안을 연구 제시하고자 한다.

  • PDF

온도의존성 열특성 계수를 고려한 화재에 노출된 철근콘크리트 골조의 해석적 연구 (Temperature-Dependency Thermal Properties and Transient Thermal Analysis of Structural Frames Exposed to Fire)

  • 한병찬;권영진;김재환;신영수;최은규
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.283-292
    • /
    • 2007
  • 본 연구는 화재에 노출된 철근콘크리트 구조물의 열적 특성 및 구조 거동을 예측할 수 있는 비정상 온도 분포 해석 및 비선형 유한요소해석 기법 개발에 관한 것으로써, 범용 유한요소해석 프로그램인 DIANA를 이용하여 화재에 의한 고온을 받는 철근콘크리트 구조에 대한 수치해석을 수행하고 그 결과를 비교분석하였다. 고온을 받는 철근콘크리트 골조에 대한 수치해석은 시간의존 비정상 온도 분포 해석과 비선형 유한요소해석의 2단계로 진행된다. 비정상 온도 분포 해석에서는 열전도율, 열용량, 열팽창계수에 대한 시간의존 변수를 온도 함수로 표현하여 이를 고려하였으며, 비선형 유한요소해석에 있어서는 콘크리트의 비선형성과 균열을 고려하기 위하여 파괴 역학적 관점을 도입하였다. 또한 철근콘크리트 단순보에 대한 내화 실험을 실시하여, 재료의 열적 특성 및 해석 기법에 대한 검증을 실시하였다. 이러한 해석 기법을 철근콘크리트 골조로 확장하여 열에 의한 콘크리트 및 철근의 역학적 물성 변화 요인을 고려한 해석을 통하여 각각의 변수에 대한 비교 분석을 수행하였다. 본 연구에서의 고온 환경하의 철근콘크리트 구조물에 대한 비선형 유한요소해석기법은 온도에 따른 재료의 열적 특성 및 역학적 성능 및 화재-온도 곡선을 자유롭게 입력하여 고려할 수 있으며, 추후 관련 해석에 용이하게 사용될 수 있을 것으로 판단되었다.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

다중 분산부하 전압강하산정 프로그램 (A Voltage Drops Computation Program on Multi-Distributed Random Loads)

  • 강차녕;권세혁;조성필
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.64-70
    • /
    • 2007
  • 전기배선에서 전압강하의 발생을 피할 수는 없다. 전기배선에서 발생되는 전압강하는 열 손실을 의미한다. 이 열은 절연체의 특성을 변화시키게 되고 이로 인하여 절연성능을 저하시키게 되며 나아가 누전, 감전, 정전 및 화재 등의 사고를 일으키는 원인이 되기도 한다. 그러므로 전기배선의 설계시에 전압강하에 대한 최적화 설계는 안전성, 경제성을 결정하는 중요한 요소가 된다. 본 연구에서는 저압의 전기설비인 가로등, 빌딩, 지하철역사 등 공공의 안전확보가 최우선 요구되는 다중 분산부하계통에서의 전압강하가 전기배선에 미치는 영향을 분석하고, 안전성 및 경제성 제고를 위한 전압강하 최적화 방안 및 설계 프로그램 개발을 하였다.

일정축력하에 고온을 받는 고강도 콘크리트 충전강관 기둥의 구조적 거동에 관한 연구 (Experimental Evaluation of Fire Behavior of High-Strength CFT Column with Constant Axial Load)

  • 정경수;최인락;김도환;김진호
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.71-80
    • /
    • 2013
  • 구조, 시공 및 내화측면에서 우수한 콘크리트충전강관(CFT)부재에 대해서 구성재료의 강도가 높은 경우 즉, 콘크리트 압축강도가 100MPa 이상이면서 강관의 항복강도가 650MPa 이상인 경우에 대한 내화성능 평가실험 및 해석적 연구는 미비한 실정이다. 본 연구에서는 이러한 부재에 대해서 내화성능 거동을 파악하고자 ${\Box}-400{\times}400{\times}15$, 부재길이 3,000mm인 실물대 중심재하 내화실험을 행하였다. 실험변수는 중심축력을 5,000kN과 2,500kN로 하였다. 실험결과, 고강도 콘크리트의 폭렬 및 콘크리트 내부 균열에 의하여 축하중이 클수록 조기에 내력을 상실하였다. 또한, 유한차분법과 변형률적합조건을 이용한 비정상온도해석 및 응력해석을 수행하였으며, 고강도 재료모델은 Eurocode모델을 이용하였다. 해석모델은 시간-축변위 관계를 합리적으로 예측할 수 있었다.

온도상승에 따른 배선용 차단기의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise)

  • 정다운;김재호
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

우사(牛舍)에서의 할로겐보온등군(群) 및 자동급수통군에 대한 전기배선의 열적 특성 (Thermal Characteristics of Electric Wiring for Halogen Warm Lamp Group and Automatic Waterer Group at Stable)

  • 김두현;유상옥;김성철
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.48-53
    • /
    • 2014
  • This study is analyzed for electrical fire danger by electric equipments through surveys of stable owners and the field investigation at 64 stable. Also, an experiment is performed to analyze the thermal characteristics of 4 types electric wiring according to the number of operating halogen warm lamp group and automatic waterer group in Beon-young stable in the Cheongwon location. The survey is done to investigate the occurrence of electrical fire, electric equipment, causes and dangerous equipment. As a result, halogen warm lamp group and automatic waterer group are found to have dangerous loads. In the field investigation, the mode of load capacity of the halogen warm lamp group and automatic waterer group was investigated. The mode of load capacity of halogen warm lamp group (over 3 years) is found 17A and that of the auto waterer group (10 years) is 16A. In this experiment, the halogen warm lamp group aged at least 3 years showed $109^{\circ}C$ while that aged less than 1 year appeared $83^{\circ}C$, showing the max gap of $26^{\circ}C$. The automatic waterer group aged 10 years showed $90^{\circ}C$ while that aged less than 1 year appeared $68^{\circ}C$, showing the max gap of $22^{\circ}C$. These findings indicate that the mode of load capacity needs to be considered in selecting and installing wiring for the electric equipment construction of halogen warm lamp group and automatic waterer group in stable.

고온하에서 다양한 설계변수에 따른 고강도 콘크리트 단주의 구조 성능 평가 (Structural Capacity Evaluation of High Strength Concrete Short Columns with Various Design Parameters under High Temperatures)

  • 김희선;문지영;박지은;신영수
    • 콘크리트학회논문집
    • /
    • 제23권5호
    • /
    • pp.637-645
    • /
    • 2011
  • 압축강도 50 MPa이 넘는 고강도 콘크리트가 화재에 취약하다는 것은 널리 알려진 사실이다. 그러나 화재 피해를 입은 고강도 콘크리트 구조 부재의 구조 성능 저감 정도를 정확하게 파악하기 위해서는 단순히 열역학적 거동만으로 파악하는 것이 아니라, 구조 거동에 대한 연구가 필요하다. 따라서 이 연구에서는 비재하 상태에서 고온에 일정시간 노출시킨 고강도 콘크리트 단주를 대상으로 하중 재하 실험을 수행하였다. 실험 변수로는 콘크리트 압축강도, 가열시간, 그리고 폴리프로필렌 섬유 혼입을 통한 폭렬 저감 공법 사용 유무가 있었으며, 실험의 결과로는 콘크리트 강도 및 가열 시간이 증가할수록 구조 성능은 저감되는 것으로 나타났다. 특히 폴리프로필렌 섬유를 혼입하여 폭렬이 저감 된 경우에도 구조 성능에는 변화가 없거나 오히려 감소하는 것으로 나타났다. 이 연구를 통하여 알아낸 바를 토대로 보다 안전하고 경제적인 내화 설계를 할 수 있으며, 또한 화재로 인한 고강도 콘크리트 구조물의 구조성능 저감 정도를 예측하는데 유용하게 활용될 수 있을 것이라고 사료된다.

데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구 (Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function)

  • 김기현;이상익;신성수;배석명;주남규
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.