• Title/Summary/Keyword: fire event

Search Result 342, Processing Time 0.033 seconds

Implementation of Automatic Extinguishing System for fire suppression of vehicle (차량 화재 진압을 위한 자동 소화 시스템 구현)

  • Ryu, Hye-Yeon;Kim, Man-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2019
  • In recent years, vehicle fires account for the second highest rate after residential fires. It accounts for more than 10.7% of the total fire occurrence rate. Vehicle fires are very difficult to evolve at an early stage. Most of the vehicles are burned down in the event of a fire, resulting in a lot of physical and personal damage. In the EU and other countries, efforts are being made to install automatic fire extinguishing systems in preparation for vehicle fires. In addition, since the automatic fire extinguishing system applied to a vehicle must operate in a moving state of a car, a method for detecting a fire is needed. Therefore, this paper proposes a structure of an automatic fire extinguishing system that can evolve a fire when a fire occurs in a commercial vehicle among various vehicles. Especially, it confirms the feasibility of the automatic fire extinguishing system simulated in the laboratory environment and confirms its applicability.

A new methodology for modeling explicit seismic common cause failures for seismic multi-unit probabilistic safety assessment

  • Jung, Woo Sik;Hwang, Kevin;Park, Seong Kyu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2238-2249
    • /
    • 2020
  • In a seismic PSA, dependency among seismic failures of components has not been explicitly modeled in the fault tree or event tree. This dependency is separately identified and assigned with numbers that range from zero to unity that reflect the level of the mutual correlation among seismic failures. Because of complexity and difficulty in calculating combination probabilities of correlated seismic failures in complex seismic event tree and fault tree, there has been a great need of development to explicitly model seismic correlation in terms of seismic common cause failures (CCFs). If seismic correlations are converted into seismic CCFs, it is possible to calculate an accurate value of a top event probability or frequency of a complex seismic fault tree by using the same procedure as for internal, fire, and flooding PSA. This study first proposes a methodology to explicitly model seismic dependency by converting correlated seismic failures into seismic CCFs. As a result, this methodology will allow systems analysts to quantify seismic risk as what they have done with the CCF method in internal, fire, and flooding PSA.

An Experimental Study on the Analysis of Evacuation Characteristics Considering the Joining of Occupants in a Building Staircase (건축물 계단실 내 재실자의 합류를 고려한 피난특성 분석에 관한 실험적 연구)

  • Kim, Yun-Seong;Huh, Ye-Rim;Choi, Yun-Ju;Kim, Hye-Won;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.204-205
    • /
    • 2021
  • In the event of a fire in a high-rise building, rapid evacuation through the stairwell is a very important factor in rapid evacuation. However, in the event of an actual fire, most of the occupants evacuate at the same time, resulting in a stay in the stairwell, reducing the evacuation speed. In Korea, conditions for buildings are created to evacuate quickly and safely while introducing performance-oriented designs to solve these problems, but there is no research data related to the evacuation speed due to joining in the event of vertical evacuation. Therefore, in this study, by analyzing the experiment conducted at W University in Japan, the density-speed relationship when staying in the staircase room was derived, and the regression equation was derived based on the results.

  • PDF

The "Warm Zone" Cases: Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters

  • Caban-Martinez, Alberto J.;Kropa, Bob;Niemczyk, Neal;Moore, Kevin J.;Baum, Jeramy;Solle, Natasha Schaefer;Sterling, David A.;Kobetz, Erin N.
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.352-355
    • /
    • 2018
  • Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the "warm zone" of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.

Causes of local collapse of a precast industrial roof after a fire

  • Bruno Dal Lago;Paride Tucci
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.371-384
    • /
    • 2023
  • Precast roofing systems employing prestressed elements often serve as smart structural solutions for the construction of industrial buildings. The precast concrete elements usually employed are highly engineered, and often consist in thin-walled members, characterised by a complex behaviour in fire. The present study was carried out after a fire event damaged a precast industrial building made with prestressed beam and roof elements, and non-prestressed curved barrel vault elements interposed in between the spaced roof elements. As a consequence of the exposure to the fire, the main elements were found standing, although some locally damaged and distorted, and the local collapse of few curved barrel vault elements was observed in one edge row only. In order to understand and interpret the observed structural performance of the roof system under fire, a full fire safety engineering process was carried out according to the following steps: (a) realistic temperature-time curves acting on the structural elements were simulated through computational fluid dynamics, (b) temperature distribution within the concrete elements was obtained with non-linear thermal analysis in variable regime, (c) strength and deformation of the concrete elements were checked with non-linear thermal-mechanical analysis. The analysis of the results allowed to identify the causes of the local collapses occurred, attributable to the distortion caused by temperature to the elements causing loss of support in early fire stage rather than to the material strength reduction due to the progressive exposure of the elements to fire. Finally, practical hints are provided to avoid such a phenomenon to occur when designing similar structures.

Evacuation Efficiency on School Auditorium Floor Layout (학교강당의 평면적 특징에 따른 대피효율에 관한 연구)

  • Kwun, Joon-Bum;Kim, Duk-Soo;Kim, Khil-Chae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.2
    • /
    • pp.3-10
    • /
    • 2017
  • This study compared evacuation effectiveness between the conventional school auditorium plan and a suggested hypothetical plan that was generated by a mathematical model, which is commonly applied in the field of industrial engineering. Recent school buildings became much more complicated in floor planning due to new social needs and modern curriculum than the old days. Nevertheless, architect's approach to floor composition in terms of fire emergency evacuation planning, still has no relation to optimized effective but relies more on an conventional school planning. Therefore, since school buildings are much more likely to be exposed to any fire related events than any other building types, emergency exit effectiveness based on spatial composition has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type(node) per floor and the minimum physical distance between spatial types(arc), can propose the most optimized spatial layout per floor regarding emergency evacuation event. Consequently, this study evaluated school's fire exit effectiveness focusing on auditorium area with the scientific tool and suggested the most reliable spatial layout regarding possibile emergency evacuation event.

Effective Evacuation based on Elementary School's Floor Layout (초등학교 층별 구성과 비상시 대피효율성의 관계)

  • Kwun, Joon-Bum;Kim, Duk-Su;Kim, Khil-Chae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.3
    • /
    • pp.3-10
    • /
    • 2016
  • This study compared evacuation effectiveness between the conventional school floor plan and a suggested hypothetical floor plan that was generated by a mathematical model that is commonly applied in the field of industrial engineering. Recent school buildings became much more complicated in floor planning due to the new educational system and modern curriculum than the old days. Nevertheless, architect's approach to floor composition in terms of fire emergency evacuation planning, still has no relation to optimized effective but relies more on a conventional school planning. Therefore, since elementary school buildings are much more likely to be exposed to any fire related events than middle school or high-school, emergency exit effectiveness based on spatial composition has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type (node) per floor and the minimum physical distance between spatial types (arc), can propose the most optimized spatial compositing per floor regarding emergency evacuation event. Consequently, this study evaluated elementary school's fire exit effectiveness with the scientific tool and suggested the most reliable spatial composition per floor regarding possibile emergency evacuation event.

A Case Study on the Evaluation Technique of Evacuation Safety in Building Fire (건축물화재시의 피난안전에 관한 평가기술에 대한 사례조사)

  • Kwon, Young-Jin;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.115-116
    • /
    • 2020
  • Recently, due to fires in high-rise residential and commercial buildings and apartments in Ulsan and Busan, the issue of evacuation safety in the event of a building fire is being closely watched. In the evacuation safety design for these building fires, it is important to secure evacuation routes considering the spatial characteristics of the building or the characteristics of the occupants and to take measures to protect the evacuation routes in order to ensure the safety of the occupants in the event of a fire. Although simulation is mainly used in Korea to assess the safety of evacuation, there is a big difference in that the Building Standards Act provides tools that can be calculated more than simulation in neighboring Japan. In addition to the evaluation method, which is called the "Building Law Assessment Methods" in Japan, the research team considered that it is important to know the process of evaluation in future domestic research, and investigated the contents of the evaluation process and wanted to apply it first to domestic buildings in the future.

  • PDF

A Study on Analysis Method of Fire path for Shipping Chemical (선박적재 화학물의 화재사고 경로 분석기법에 관한 고찰)

  • Kang, Yu-Mi;Yang, Hyeongsun;Park, Deuk-Jin;Yim, Jeong-Bin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.267-267
    • /
    • 2019
  • The purpose of this study is to understand the risk of chemical product, Styrene Monomer(SM), shipped in a vessel. SM is harmful chemical product which can make injury, explosion and/or fire in a vessel. The understand of SM risk is very important to protect seafarer's body and vessel safety. This research can be expected that the understanding of SM risk by a seafarer's to prevent accidents by SM explosion/fire. In this study we used event tree analysis method using chemical reaction cased by explosion. As a result, we founded various chemical reaction and visualization for explosion path.

  • PDF

Action Plan of Security Service against a Fire case in a Tall Building Event (경호행사시 초고층건물 화재 대응방안)

  • Son, Kyung-Hwan
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.37-61
    • /
    • 2014
  • Nowadays the world is threatened because of terrors that take aim at Soft-Targets available and easy to access to the people rather than more secured Hard-Targets. The inspection department of the Presidential Security Service develops and acts a perfect safety plan wherever the President stays so that it is possible to get immediate actions for various contingencies. Some events, in which the President take part, could be held in a lower or higher store in a tall building. Additional to the routine work at this case it is to emphasize on a plan of fire precaution to check the spot and respond to a real fire situation, so that the damage could be minimized. First, the agents of the President Security Service should possess basic knowledge concerning to the fire accidents and be trained on their manuals, even in a busy events plan. An organization, whatever it is, could be improved in that it tries to develop not only the personal abilities, but also education programs of the organization continually. And enhanced abilities of the members lead to the driving force for the advance. The knowledge of fire accident should be able to adapt to the real situation. Second, related to the event, it should be cooperated with the relevant departments, so that it is possible to conduct and control the system. It is urgently required to know that the security event could not be done perfectly with only one part or department. Third, from the time of recognizing of the event it is necessary for the fire department to get an action plan with fire fighting measures, evacuation measures based of the instructions given by the Security Service. Fourth, on the knowledge of the action plan of the fire department the Security Service should inspect the safety activities of the spot and establish the practical operation plan through the fire fighting and evacuation plan. Fifth, the Security Service should share final informations and plan of fire fighting in a high-rise building with the other relevant departments. If not, it could cause a great confusion that could lead to a great damage.

  • PDF